68 EOT Telemetry DevicesReplace the battery in the EOT unit as follows:1. To unlock the EOT unit and remove the dead battery:a. Unlock the unit and swivel the handle down.b. Rotate the lock hasp off the battery latch and open bothlatches.c. Remove the latch hooks from the battery lid.d. Pull the battery out from the EOT enclosure.2. To install a new battery:a. Install a fully charged battery in the EOT battery enclosure.b. Align the connector on the battery with the round matingconnector at the bottom of the battery enclosure.c. Push the battery fully into the enclosure and latch the batterylid.3. To resecure the EOT unit:a. Rotate the lock hasp and the handle together.b. Lock the unit through the lock hole.68.3 TRAINLINK II Locomotive Cab UnitThe locomotive cab unit (LCU) is a self-contained telemetry transmitter/receiverwith the displays and controls the engineer uses tomonitor and operate the EOT unit.68.3.1 LCU Displays and ControlsThe LCU has the following displays and controls:A. Distance CounterThe distance counter measures the net distance (whether forward orin the reverse position) a locomotive travels.June 1, 1996 ARRC Air Brakes and Train Handling Manual 68-5

68 EOT Telemetry DevicesActivating the Distance Counter. To activate the distance counter:1. Press the CONTROL button (on the left side of the LCU frontpanel) one time, which then displays the distance the locomotivehas travelled in feet.NOTE: At first the distance increases whether the train istravelling forward or in the reverse position. However, if thetrain reverses direction, the distance counter begins decreasing.2. Press the CONTROL button a second time, which holds thedisplay at the net (forward or reverse) distance the locomotivetraveled. The display will flash.NOTE: If the distance count reaches its maximum value of± 19,999 feet, the count will freeze and the display will flash.3. Press the CONTROL button a third time, which resets and turnsoff the distance counter display.Calibrating the Distance Counter. To calibrate the distancecounter:1. Set the two-digit WHEEL DIAMETER switch (on the right sideof the LCU rear panel behind a small access door) by dialing thesecond and third digits (which represent wheel diameter) on theswitch. For example, for a 38.0-inch wheel, disregard the “3”and dial the “8” and “0” on the switch.NOTE: This two-digit switch accommodates wheel diametersfrom 35.0 to 44.9 inches.2. Check the wheel diameter setting as follows:a. Press and hold the DISPLAY TEST button on the LCU,which displays the wheel size setting on the DISTANCECOUNTER display. For example, a wheel size setting of38.0 inches would be displayed as “38.0.”NOTE: Charge units are also displayed in the PRES-SURE DISPLAY window.68-6 ARRC Air Brakes and Train Handling Manual June 1, 1996

68 EOT Telemetry DevicesActivating the Distance Counter. To activate the distance counter:1. Press the CONTROL button (on the left side of the LCU frontpanel) one time, which then displays the distance the locomotivehas travelled in feet.NOTE: At first the distance increases whether the train istravelling forward or in the reverse position. However, if thetrain reverses direction, the distance counter begins decreasing.2. Press the CONTROL button a second time, which holds thedisplay at the net (forward or reverse) distance the locomotivetraveled. The display will flash.NOTE: If the distance count reaches its maximum value of± 19,999 feet, the count will freeze <strong>and</strong> the display will flash.3. Press the CONTROL button a third time, which resets <strong>and</strong> turnsoff the distance counter display.Calibrating the Distance Counter. To calibrate the distancecounter:1. Set the two-digit WHEEL DIAMETER switch (on the right sideof the LCU rear panel behind a small access door) by dialing thesecond <strong>and</strong> third digits (which represent wheel diameter) on theswitch. For example, for a 38.0-inch wheel, disregard the “3”<strong>and</strong> dial the “8” <strong>and</strong> “0” on the switch.NOTE: This two-digit switch accommodates wheel diametersfrom 35.0 to 44.9 inches.2. Check the wheel diameter setting as follows:a. Press <strong>and</strong> hold the DISPLAY TEST button on the LCU,which displays the wheel size setting on the DISTANCECOUNTER display. For example, a wheel size setting of38.0 inches would be displayed as “38.0.”NOTE: Charge units are also displayed in the PRES-SURE DISPLAY window.68-6 ARRC <strong>Air</strong> <strong>Brakes</strong> <strong>and</strong> <strong>Train</strong> H<strong>and</strong>ling Manual June 1, 1996

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!