A diagnostic popup can be activated to display the standard and extended diagnosisfor a sensor.The screen capture shown above displays the various measurement states anderrors for a specific sensor.The slave address can be modified to get diagnostic information for another sensorby selecting the DIAG button.102

Asset Management ExampleIntroductionAsset Management Software allows you to execute several operations, either on-lineor off-line, specifically:Device Configuration and ParameterizationAs an example the following parameters can be modified using Asset managementtool.• Device tag, device type selection• Unit selection, date-time initialization• Bus address, device data allocation setup• Device calibration, scaling factors• Warning and alarm threshold valuesDevice Monitoring and ControlDifferent types of operation can be done such as :• Measurement tracking, actuator control• Simulated manipulationsDevice Identification and DiagnosticStandard and extended diagnosis data can be get for all instrument connected onProfibus PA. For instance :• Hardware identifier, serial number, software version• Event and alarm reportingPrincipleAfter connecting to the network, the list of equipment can be discovered automaticallyor read from an existing file.103

Asset Management ExampleIntroductionAsset Management Software allows you to execute several operations, either on-lineor off-line, specifically:Device Configuration and ParameterizationAs an example the following parameters can be modified using Asset managementtool.• Device tag, device type selection• Unit selection, date-time initialization• Bus address, device data allocation setup• Device calibration, scaling factors• Warning and alarm threshold valuesDevice Monitoring and ControlDifferent types of operation can be done such as :• Measurement tracking, actuator control• Simulated manipulationsDevice Identification and DiagnosticStandard and extended diagnosis data can be get for all instrument connected on<strong>Profibus</strong> PA. For instance :• Hardware identifier, serial number, software version• Event and alarm reportingPrincipleAfter connecting to the network, the list of equipment can be discovered automaticallyor read from an existing file.103

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!