12.07.2015 Views

Report - PEER - University of California, Berkeley

Report - PEER - University of California, Berkeley

Report - PEER - University of California, Berkeley

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

outline and evaluate an improved procedure that retains the conceptual simplicity andcomputational attractiveness <strong>of</strong> current methods.2. NONLINEAR STATIC PROCEDURE: CURRENT PRACTICEThe nonlinear static procedure (NSP) in FEMA-356 requires development <strong>of</strong> apushover curve, a plot <strong>of</strong> base shear versus ro<strong>of</strong> displacement, by nonlinear staticanalysis <strong>of</strong> the structure subjected first to gravity loads, followed by monotonicallyincreasing lateral forces with a specified, invariant height-wise distribution. Thelimitations <strong>of</strong> force distributions in the FEMA-356 nonlinear static procedure aredemonstrated in Figs. 1 and 2 where the resulting estimates <strong>of</strong> the median story driftand plastic hinge rotation demands imposed on the SAC buildings by the ensemble <strong>of</strong>20 SAC ground motions are compared with the “exact” median value determined bynonlinear RHA <strong>of</strong> the buildings. The first-mode force distribution grosslyunderestimates the story drifts, especially in the upper stories, showing that highermodecontributions are especially significant in the seismic demands for upper stories.Although the ELF and SRSS force distributions are intended to account for highermode responses, they do not provide satisfactory estimates <strong>of</strong> seismic demands. The“uniform” force distribution seems unnecessary because it grossly underestimatesdrifts in upper stories and grossly overestimates them in lower stories <strong>of</strong> fourbuildings. The FEMA-356 lateral force distributions either fail to identify, orsignificantly underestimate, plastic hinge rotations in beams at uppers floors.9BostonSeattleLos AngelesFloorNonlinear RHA6FEMA1st ModeELF3SRSSUniform9−StoryG0 0.5 1 1.5 220160 1 2 3 4 50 2 4 6 8Floor128420−StoryG0 0.5 1 1.5 2 0 1 2 3 4 5 0 1 2 3 4 5 6Story Drift, ∆ , or ∆ (%)NL−RHA FEMAFigure 1. Median story drifts determined by nonlinear RHA and four FEMA-356 force distributions: 1 st Mode, ELF, SRSS, and “Uniform.”334

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!