For the utmost of complex requirements<strong>GEA</strong> <strong>Air</strong> FiltersCustomised and efficient air treatment<strong>Air</strong> <strong>Treatment</strong>


A clear signal for tested-and-proven filter quality in conformity with the stricteststandards: i.e., DIN EN 779 and DIN EN 1822. Throughout the world, only9 companies are authorized to use the Eurovent seal (as of September 2008).PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/20093


In almost 100 years of corporate history, <strong>GEA</strong> <strong>Air</strong> <strong>Treatment</strong> has developed a great numberof highly specific filter solutions for the food and beverage industries – both for conventionalas well as for complex applications.4PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


An extensive application spectrumA product portfolio with more than 2,000standard and specialised filters<strong>GEA</strong> air filters cover all areas of application in which pollutantsand suspended particulate matter must be removed fromcontaminated air in production facilities.A great number and variety of work processes contaminate roomair with pollutants and suspended particulate matter – contaminationthat in many cases is highly dangerous. Such conditionsnot only endanger human health, but also the quality of machinesand products. While sterile atmospheres are essential inmany situations (e.g., in operating theatres), other areas may demandabsolute absence of dust in the air (for example, with sensitivesystems in the optical industry).Whatever user profile your rooms must fulfil: there is always a<strong>GEA</strong> air filter that satisfies your individual requirements. Thecurrent <strong>GEA</strong> filter portfolio includes more than 2,000 differentstandard and special filters to assure fresh, pure air in all areas.The finest emulsion mists, toxic vapours, fine-particulate dust,and material removed during manufacturing processes: all arereliably filtered out by <strong>GEA</strong> filters – as are bacteria, fungal spores,and viruses.In addition, <strong>GEA</strong> air filters powerfully support cost-effectiveprocess management. They noticeably reduce consumption costsfor power, heat, and water – and dependably conform to legalregulations. As a planner, you also profit from a maximum offlexibility. The great number of variation possibilities means thatyou will find at <strong>GEA</strong> a customised filter solution for any and allof your projects.Areas of application for <strong>GEA</strong> air filters:Industrial productionPharmaceuticals and life sciencesHospitals and laboratoriesSemiconductor productionTrade and service activitiesFood and beverage industriesPR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/20095


OverviewFilter classesThe most important criteria for selecting air filters is the separationcapacity and efficiency required. We provide test certificationthat documents the technical specifications for theperformance of our filters.Our product brochures provide detailed information on <strong>GEA</strong> airfilters. We’ll gladly advise you at length and deliver you highqualityair filters or filter media according to your requirements– also for retooling or retrofitting purposes.Filter classes G1 – G4: Coarse-dust filter with medium degree of separation, according to DIN EN 779Filter classes F5 – F9: Fine-particulate dust filters with medium filter efficiency according to DIN EN 779H10 – H14 and U15: High-efficiency submicron particulate air filters (HEPA) and ultra-low-penetration air filters(ULPA) according to DIN EN 18226PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


Purity classes according to general directivesAmerican Standard 209E 100,000 10,000 1,000 100 10 1German standard VDI2083 6 5 4 3 2 1British Standards BS 5295 (1989) K J H-G F-E D CEC Directive (for pharmaceuticals) D C B-A B-A A APurity class per ISO 14 644 ISO Class 8 ISO Class 7 ISO Class 6 ISO Class 5 ISO Class 4 ISO Class 3Healthcare systemsPharmaceutical industryResearchMaximum sterile surgical areasPreliminary areas before maximum sterilesurgical areasSterile and contaminated surgical areasPreliminary areas before sterileand contaminated rooms<strong>Treatment</strong> areasIntensive-care units for burns and transplantationsIntensive-care units for post-operative treatmentStations for anaesthesiology, resuscitation, and intensive carePharmacy – production of cytostatic agentsClean benchWall panelling for interior wall systemsPartition wall for types R and ECRW windowsRecessed lightingRectangular-grid ceilingFilter-mount frame CGF with built-in HEPA filter,filter class H13PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/20097


Filter overviewFilter class as perDIN EN 779 orDIN EN 1822Filter mats, rolls,and special-dimension Roll-band Filter plates Filterelements filters Bag filters and cells elementsApplication examples- Paint-mist filtersFARBGLAS 2“- Pre-filters for high dust G2concentrations- Supply air for the cooling oflarge machines- Filters for specific coarse dusttypesCTM 50FIBROIDELASTIC-20FIBROIDELASTIC-30- Pre-filters for fine-dust filters G3- Pre-filters for the steel andmetallurgical industries;for offshore facilities in arid climates- Filters for machine-room ventilation- Filters for protection of heatexchangerassemblies- Pre-filters for climate-control facilitiesCTM 60 FIBROBAND GAL stainless steelFIBROIDELASTOV-10 402 GAL aluminiumFIBROIDELASTOV-20 411 HL 12.5 (dual-plate)FIBROIDELASTIC-40 412VENUFA 290G4CTM 90 MULTISACK-K35 FILTERGLASFIBROIDELASTOV-40HL 12.5 (triple-plate)MY-STOP 500 ULTRANGLAS / -HZ-50 / Z-100- Separation of superfine dust, F5for great air purity- Supply air for sensitive switchgearand paint-spray compartmentsACELANPERFEKT-600MULTISACK-G55MULTISACK-K50MULTISACK-K55- Separation of superfine dust in the F6pharmaceutical, electrical,and photo industries- Partial and full climate-control systemswith great air purity- Laboratories and hospital roomsMULTISACK-G65MULTISACK-K65MULTIFORM-65MULTITHERM-60MULTIPLAN-65- Separation of superfine dust in F7climate-control systems with verygreat air purity- Supply air for precision assembly F8rooms and switchgear facilities- For production of food and beverages- Pre-filters for clean-room facilities F9in the pharmaceutical industries- pre-filters for hepa + ulpa filtersH10MULTISACK-G85MULTISACK-K85MULTISACK-K95MULTISACK-G95MULTIFORM-85MULTIPLAN-85MULTIFORM-90MULTITHERM-90MULTIFORM-95MULTIPLAN-95MULTIFORM-98H11MULTIFORM-99H12MULTIFORM-1008PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


Filter overviewFilter class as perDIN EN 779 orDIN EN 1822Elements for high-efficiency Filter framessubmicron particulate Activatedairfilter (HEPA) carbon filters For filter media Round air filtersApplication examples- Fine and superfine dust separation, H10by application of suitablepre-filters (at least G4 and F7)H11- Supply air for precision assembly roomsand switchgear facilities- For production of food and beverages H13- Sterilisation rooms and operating theatres- Clean-room facilities in thepharmaceutical industryH14- Clean-room facilitiesMICROPUR-FMICROPUR-FVMACROPURMACROPUR-FMACROPUR-FVABSOPUR-FABSOPUR-FVU15U16ULTRAPUR-FSUPRAPUR-F- Separation of gaseous, odour-intensive,toxic, and/or radioactive air pollutantsActivated-carbonelement AK-20Cartridge no. 705Cartridge no. 706Cartridge no. 707Cartridge no. 708Cartridge no. 709Multi 2004-AKKMulti 2004-AKSActivated carbon,looseFilter holding frame CKG- All areas of application for selectionof the applicable filter classand built-in framesWall frame CDD<strong>Air</strong> outlet CGF- Purification of intake airfor internal-combustion engines and fans- Application for piston compressorsRound air filtersDAHDACDBHDBVDBADBC- Intake and outlet air forlaboratory equipmentGlove-box filtersDKADKBDKCDKDCOPULAR CKLPR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/20099


Filter mats, rolls, and special-dimension elementsFilter classG2 G3 G4G2 G2 G3G3 G3 G4DesignationCTMFIBROIDELASTICFIBROIDELASTOVType50 60 9020 30 4010 20 40RegenerableYes Yes YesYes Yes YesYes Yes YesForm of delivery *CTM consists of polyester fibres withFIBROIDELASTIC consists ofFIBROIDELASTOV is a robust fleecepronounced labyrinth structure andlatex-bonded, randomly structuredmade of randomly structuredwith progressive depth structure.natural mixed fibres with uniformpolyester fibres with progressiveCTM is elastic, not provided with adepth structure and great intrinsicdepth structure. The filter layer, notwetting agent, and regenerable.stiffness. FIBROIDELASTIC is elastic,provided with a wetting agent, isnot provided with a wetting agent,elastic and regenerable.and repeatedly regenerable.Technical filter datain accordance with DIN EN 779Pressure drop (Pa)75604530150CTM-90CTM-60CTM-500 1750 3500 5250 7000<strong>Air</strong> volume (m³/h*m²)Pressure drop (Pa)10080604020TIC-40TIC-30TIC-2000 2500 5000 7500 10000<strong>Air</strong> volume (m³/h*m²)Pressure drop (Pa)200TOV-40160120TOV-208040TOV-1000 2500 5000 7500 10000<strong>Air</strong> volume (m³/h*m²)Mean degree of separation (%)72 81.4 91.773.1 77.1 84.681 87 93Mean filter efficiency (%)– – –– – –– – –Max. allowed pressure drop(Pa)250 250 250250 250 250250 250 250Operating temperature(max. °C)80 80 8060 60 6080 70 70Installation depth/thickness(mm)5 10 2020 30 4010 20 40* Please see page 27 for an explanation of the symbols used under “Form of delivery.”10PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


Filter mats, rolls, and special-dimension elementsFilter classG3G4F5DesignationVENUFA 290MY-STOP 500ACELANRegenerableYesYesNoForm of delivery *VENUFA 290 consists of polyesterMY-STOP 500 consists of polyesterACELAN consists of thermallyfibres with progressive depthfibres that have been spun tobonded polyester fibres. The elasticstructure. VENUFA 290 is elastic,produce a very robust fleece withmedium is not provided with anot provided with a wetting agent,progressive structure. The especiallywetting agent, is progressive, and isand is regenerable.smoothed pure-air side preventsconstructed with compression onmigration of fibres and assures greatthe pure-air side.dust-storage capacity. MY-STOP 500VENUFA 290 is elastic, not providedwith a wetting agent, and isregenerable.Technical filter datain accordance with DIN EN 779Pressure drop (Pa)5040302010VEN-290Pressure drop (Pa)605040302010MY-500Pressure drop (Pa)16014012010080604020ACELAN00 1750 3500 5250 7000<strong>Air</strong> volume (m³/h*m²)00 1750 3500 5250 7000<strong>Air</strong> volume (m³/h*m²)00 1750 3500 5250 6400<strong>Air</strong> volume (m³/h*m²)Mean degree of separation (%)87.794.496.6Mean filter efficiency (%)––43.5Max. allowed pressure drop(Pa)250250450Operating temperature(max. °C)808080Installation depth/thickness(mm)202030PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/200911


Filter mats, rolls, special-dimension elements, and filter bands for roll-band filter systemsFilter classF5–G3DesignationPERFEKTFARBGLAS 2“FIBROBANDType300 600––RegenerableNoNoNoNoForm of delivery *PERFEKT-300 consists of superfine,FARBGLAS 2“ consists of a spunFIBROBAND consists of fine,thermally bonded polyester fibresglass-fibre fabric with compressionrandomly structured polyesternot provided with a wetting agent,on the pure-air side. The glass-fibrefibres. The filter layer is constructedwith progressive structure, and withmedium has no wetting agent and ison a stiff, tear-resistant polyestercompression on the pure-air side.odourless, non-inflammable, andgauze. It is mounted on aPERFEKT-300 is wetted with ainsensitive to moisture in the air.cardboard spool with insertionbond-active agent, and its pure-airsleeve for the DELBAG system.side is reinforced with a lattice-structured fabric.Technical filter datain accordance with DIN EN 779Pressure drop (Pa)70605040302010PF-600PF-300Pressure drop (Pa)40302010FAGL 2Pressure drop (Pa)5040302010FIBROBAND00 500 1000 1500 200000 1500 3000 4500 600000 1750 3500 5250 7000<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)Mean degree of separation (%)96,4 97,997(with respect to paint mist)88,1Mean filter efficiency (%)53,5 56,6––Max. allowed pressure drop(Pa)450 45080250Operating temperature(max. °C)80 8012080Installation depth/thicknes(mm)15 205010*Please see page 27 for an explanation of the symbols used under “Form of delivery.”12PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


Bag filters (synthetic)Filter classG4F5F5F6F7F8DesignationK35K50K55K65K85K95RegenerableNoNoNoNoNoNoForm of delivery *The MULTISACK bag filter is composed of several filter bags. The individual bags, made of synthetic fleece, havebeen shaped so as to provide wedge-shaped filter bags. The spacers in the individual filter bags ensure completeutilization of the full bag depth and, in turn, of the entire filter surface. The ready-to-install filter bags are securedto sturdy U-shaped profile frames (25 mm) by clamp fittings.Technical filter datain accordance with DIN EN 779These plots are valid forsize 592 x 592 mm.200200200K-95Pressure drop (Pa)15010050K-50Pressure drop (Pa)15010050K-65K-55Pressure drop (Pa)15010050K-85K-3500 850 1700 2250 3400 425000 850 1700 2250 3400 425000 850 1700 2250 3400 4250<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)Mean degree of separation (%)90 96.998 98.2> 99 > 99Mean filter efficiency (%)– 46.147.7 60.584.9 92.3Number of filter bags(each)Dimensions: 592 x 592 mmallowed pressure drop (Pa)Operating temperature (max. °C)Installation depth / thickness (mm)4 / 6 6250 45080 80360 5006 6 / 8450 45080 80600 6006 / 8 8450 45080 80600 600PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/200913


Bag filters (glass)Filter classF5F6F7F9DesignationG55G65G85G95RegenerableNoNoNoNoForm of delivery *The MULTISACK bag filter is composed of several filter bags. The individualbags, made of micro-fibreglass fleece, have been shaped so as to providewedge-shaped filter bags. The spacers in the individual filter bags ensurecomplete utilization of the full bag depth and, in turn, of the entire filtersurface. The spacer seam is sealed. The ready-to-install filter bags aresecured to sturdy U-shaped profile frames (25 mm) by clamp fittings.Technical filter datain accordance with DIN EN 779These plots are valid forsize 592 x 592 mm.200200G-95Pressure drop (Pa)15010050G-55 + G-65Pressure drop (Pa)15010050G-8500 850 1700 2250 3400 4250<strong>Air</strong> volume (m³/h*m²)00 850 1700 2250 3400 4250<strong>Air</strong> volume (m³/h*m²)Mean degree of separation (%)Mean filter efficiency (%)Number of filter bags(each)Dimensions: 592 x 592 mmallowed pressure drop (Pa)Operating temperature (max. °C)Installation depth / thickness (mm)96.8 98.450.4 62.86 8 / 10450 45080 80600 600> 99 > 9988.4 95.48 / 10 8 / 10450 45080 80600 600*Please see page 27 for an explanation of the symbols used under “Form of delivery.”14PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


Filter platesFilter classG3G3G3G4DesignationGAL-ALUMINIUMGALstainlesssteelHL 12.5Dust-trapping agentVISCINOL A 30RegenerableYesYesYesYes–Form of delivery *Several layers of aluminium orstainless-steel woven wire mesh areinstalled between metal supportplates made of expanded metalmesh on two sides, and are framedby a sturdy U-shaped profile framemade of aluminium or stainlesssteel. The filter cells are regenerable.The HL 12.5 filter plates consist ofseveral layers of bonded expandedmetal mesh, which is effective forseparation of coarse dust owing tothe labyrinth structure of the plates.The filter plates are wetted with adust-trapping agent (VISCINOL), andare regenerable.The HL 12.5 filter plates are wettedwith the dust-trapping agentVISCINOL. The wetted plates areregenerable.Technical filter datain accordance with DIN EN 779These plots are valid forsize 494 x 494 mm.Pressure drop (Pa)907560453015GAL-AGAL-NPressure drop (Pa)2001601208040Triple-plateDualplate00 2500 5000 7500 10000<strong>Air</strong> volume (m³/h*m²)00 2500 5000 7500 10000<strong>Air</strong> volume (m³/h*m²)Mean degree of separation (%)87 8686 91–Max. allowed pressure drop(Pa)500 500500 500–Temperature range(°C)– –– –-15 bis +45Package unit(I)– –– –5, 20, 200Operating temperature(max. °C)400 400max. 60 1) max. 60 1)–Installation depth / thickness (mm)48 482 x 12 3 x 12–1)Depending on wetting agent.PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/200915


Filter cellsFilter classG4G4G4G4G4DesignationFILTERGLASULTRANGLAS ULTRANGLAS-HZ-50 Z-100RegenerableNoNoNoNoNoForm of delivery *FILTERGLAS consists of tightlyULTRANGLAS / -H consists of tightlyThese air-filter cells consist ofintermeshed glass fibres with specialintermeshed glass fibres.pleated synthetic fleece in a sturdy,closure fleece on the pure-air side.ULTRANGLAS is framed on two sideswater-repellent, impregnatedOn two sides, the filter cell is framedin a moisture-resistant carton framecarton frame with supportingwith large-perforation metalwith large perforation in the metallattices on the dust and pure-airsupport plates in a moisture-resi-support plates. ULTRANGLAS / -H issides. The filter medium is folded instant carton frame enclosure with aframed on all sides in expandedV shape and enables great air-flowcrimp fold.aluminium mesh. The filter cell isrates with low pressure drop anddesigned for operating temperaturescompact installation sizes. The filterup to 300°C.medium is not regenerable.Technical filter datain accordance with DIN EN 779These plots are valid forsize 494 x 494 mm.Pressure drop (Pa)1601208040FILTER-GLASPressure drop (Pa)2001601208040U-GLAS-HU-GLASPressure drop (Pa)10080604020Z-50-G4Z-100-G400 250 500 700 100000 375 750 1125 150000 2000 4000 6000 8000<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)Mean degree of separation (%)9693 9392 93Mean filter efficiency (%)–– –– –Max. allowed pressure drop(Pa)500500 500250 250Operating temperature(max. °C)8080 30070 70Installation depth/thickness(mm)1448 1447 92* Please see page 27 for an explanation of the symbols used under “Form of delivery.”16PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


Filter cellsFilter classDesignationRegenerableF5FIBERGLASNoForm of delivery *FIBERGLAS consists of tightlyintermeshed glass fibres with specialclosure fleece on the pure-air side.On two sides, the filter cell is framedwith large-perforation metalsupport plates in a moisture-resistantcarton frame enclosure with acrimp fold.Technical filter datain accordance with DIN EN 779These plots are valid forsize 480 x 480 mm.Pressure drop (Pa)2001801601401201008060402000FIBERGLAS100 200 300 400 500<strong>Air</strong> volume (m³/h*m²)Mean degree of separation (%)Mean filter efficiency (%)Max. allowed pressure drop (Pa)Operating temperature (max. °C)Installation depth/thickness (mm)9955.44508014PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/200917


Filter elementsFilter classF6 F7 F8F9 H10 H11H12DesignationMULTIFORMMULTIFORMMULTIFORMType65 85 9095 98 99100RegenerableNo No NoNo No NoNoForm of delivery *During production, the filter medium made of micro-fibreglass fleece is pleated to form a stable package of folds.The number and the height of the folds are optimally designed to match operating conditions. The individual filterplates are arranged in a V-shape (in 4 compartments) inside a synthetic frame made of ABS, so as to assure astable form of the filter plates, and are glued to assure airtightness .Technical filter data nachwith DIN EN 779 and/or DIN EN 1822These plots are valid forsize 592 x 592 mm.Pressure drop (Pa)20015010050MF-90MF-85MF-65Pressure drop (Pa)25020015010050999895Pressure drop (Pa)4003503002502001501005010000 1275 2550 3825 510000 850 2550 425000 850 2550 4250<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)Mean degree of separation (%)As per DIN EN 779As per DIN EN 1822> 98 > 98 > 98– – –> 98 – –– > 85 > 95–> 99.5Mean filter efficiency (%)72.6 85.9 93.596.2 – ––Max. allowed pressure drop(Pa)450 450 450450 650 650650Operating temperature(max. °C)70 70 7070 70 7070Installation depth / thickness (mm)298 298 298298 298 298298* Please see page 27 for an explanation of the symbols used under “Form of delivery.”18PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


Filter elementsFilter classF6F8F6 F7 F9F6 F7 F9DesignationMULTITHERMMULTIPLANMULTI 2004Type60 9065 85 95MF65 MF85 MF95RegenerableNoNoNo No NoNo No NoForm of delivery *The filter medium consists of deeplyThe filter medium used is special,The steel frame is corrosion-resi-folded, paper-like micro-fibre fleece.paper-like fleece made of superfinestant as a result of an RAL 9011The position of the folds is stabilisedmicro-glass fibres, which aresurface finish. In the system frame,either by wave-shaped aluminiumprocessed to form a stable packagethe filter inserts are inserted with aseparators, or by filter-material stripsof folds. As standard version, themagnetic-strip seal, in V shape. Theto separate the folds. The filterfilter element is provided with apleated filter packs are gluedpackage is inserted dry in a filterperipheral seal on the intakeairtight in a moisture-resistantframe made of sendzimir-galvanised(dusty)-air side. The filter frame iscarton frame.sheet steel, with grip protection onmade of MDF.both sides. All materials satisfystipulations pertaining to the absenceof silicone, and are temperatureresistant up to 250°C.Technical filter datain accordance with DIN EN 779These plots are valid forsize 610 x 610 mm for MULTITHERM;otherwise, for 592 x 592 mm.Pressure drop (Pa)2001601208040MT-90-TMT-60-TPressure drop (Pa)2001601208040MP-85MP-95MP-65Pressure drop (Pa)25020015010050MF-95MF-8500 850 1700 2550 3400 4250<strong>Air</strong> volume (m³/h*m²)00 750 1500 2250 3000<strong>Air</strong> volume (m³/h*m²)MF-650 0 850 1700 2550 3400 4250<strong>Air</strong> volume (m³/h*m²)Mean degree of separation (%)As per DIN EN 779Mean filter efficiency (%)Max. allowed pressure drop (Pa)Operating temperature (max. °C)> 98 > 9860.5 90.5450 450250 25098 > 99 > 9960 80 95450 450 45080 80 80> 98 > 98 > 9860 80 95450 450 45080 80 80Installation depth / thickness (mm)40 / 55 / 78 / 292 –46 / 78 / 150 / 292 – –304 304 304Flat seal+6 –+8 – –– – –PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/200919


High-efficiency submicron particulate air filters (HEPA)Filter classH11H11H13DesignationMICROPUR–FMICROPUR–FVMACROPURForm of delivery *The packages of folds are cast in The packages of folds are cast so asa frame with polyurethane so as to be airtight in a U-shaped profile.to be airtight.They have a V-shaped arrangement.The special, paper-like fleece made of superfine micro-glass fibres isprocessed by pleating to form a stable package of folds. Here the individualfolds are separated down to the greatest depth of the folds by continuoussynthetic threads that are bonded together, which provides great stabilityas a result of the compact fold structure. Available frames: MDF, plywood,aluminium, and stainless steel.For stabilisation, these filters usewave-shaped aluminium separatorsinstead of synthetic threads. Thepackages of folds are cast in awooden frame with polyurethane,so as to be airtight.Technical filter datain accordance with DIN EN 1822Pressure drop (Pa)150125100755025Pressure drop (Pa)20015010050Pressure drop (Pa)250200150100500000 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)Degree of separation (%)> 95> 95> 99.95Max. allowed pressure drop(Pa)750750750Operating temperature(max. °C)808080Installation depth+ thickness + seal(mm)4 6 / 5 4 / 78 / 15 0 / 2 92+8292+8150 / 292+8* Please see page 27 for an explanation of the symbols used under “Form of delivery.”20PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


High-efficiency submicron particulate air filters (HEPA)Filter classH13H13H14DesignationMACROPUR-FMACROPUR-FVABSOPUR-FForm of delivery *The package of folds is cast withThe packages of folds are castThe packages of folds are castpolyurethane in an MDF frame,airtight in U-shaped profiles,airtight in aluminium frames, andso as to be airtight.and are arranged in a V shape.are provided with grip protectionon the pure-air side.The special, paper-like fleece made of superfine micro-glass fibres is processed by pleating to form a stable packageof folds. Here the individual folds are separated down to the greatest depth of the folds by continuous syntheticthreads that are bonded together, which provides great stability as a result of the compact fold structure. Availableframes: MDF, plywood, aluminium, and stainless steel.Technical filter datain accordance with DIN EN 1822250250200Pressure drop (Pa)20015010050Pressure drop (Pa)20015010050Pressure drop (Pa)150100500 000 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)<strong>Air</strong> volume (m³/h*m²)Degree of separation (%)> 99.95> 99.95> 99.995Max. allowed pressure drop(Pa)750750600Operating temperature(max. °C)808080Installation depth+ thickness + seal(mm)4 6 / 5 4 / 78 / 15 0+8292+869–PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/200921


Activated carbon cartridgesDesignationTypeRegenerableActivated-carbon cartridges705 706 707Yes Yes YesActivated-carbon cartridges708 709YesYesForm of delivery *These activated-carbon cartridgesconsist of perforated, concentricsynthetic cylinders.The interstices of the cartridge arefilled with activated carbon. Thecarbon content can be replaced.These activated-carbon cartridgesconsist of perforated sheet steel orof stainless steel. The carboncontent can be replaced.Technical filter data1600Contact period (s) 0.30 0.14 0.10 0.07 0.06250Pressure drop (Pa)1200800400707705 / 706Pressure drop (Pa)2001501005070800 25 50 75 100<strong>Air</strong> volume (m³/h*m²)12500 50 100 150 200<strong>Air</strong> volume (m³/h*m²)Grain size: 1.5 mm250Activated-carbon typeLength(mm)Used inVolume of activated carbon (I)Operating temperature(max . °C)Layer thickness(mm)AKOLIT-A291 291 291– – –1.7 1.7 1.7– – –21 22 31AKOLIT-A450 600CKG holdingframe4.0 5.340 4026 26* Please see page 27 for an explanation of the symbols used under “Form of delivery.”22PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


Holding framesDesignationTypeRegenerableHolding framesCKG–Holding framesMULTI 2004with air-filter elementNoForm of delivery *Individual, exchangeableactivated-carbon bayonet-fitted type708/709 cartridges are used inframes made of galvanised orstainless steel. The frames are usedin duct air filters, or as wall frames.The filter medium consists of aspecial, open-pore synthetic foamthat is filled (to be abrasion-resistant)with activated carbon in the form ofpowder or globules. The filter insertsare slid in (in V form) into thepowder-coated system frames, whichhave sturdy forms.Technical filter data1600Pressure drop (Pa)1200800400592 / 592(size in mm)00 850 1275 1700 2125 2550<strong>Air</strong> volume (m³/h*m²)Activated-carbon typeUsed in:Volume of activated carbon (I)Operating temperature (max . °C)Layer thickness/installation depth (mm)AKOLIT-AEBE duct filters;wall installation64 84.8– –450 600Activated-carbon foamActivated-carbon globulesEBE duct filters;CDD wall frames30.040304PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/200923


Glove-box filters; COPULAR air filtersCharacteristicsCartridge enclosuresCartridge enclosuresCOPULAR air filtersDesignationDKADKBDKCDKDCKLGlove-box filters are high-efficiency submicron particulate air filters (HEPA) inencapsulated form (model types DKA and DKB). In special application cases,glove box filters are combined with a gas sorption filter (model types DKCand DKD). The filters can be installed on the air-intake or the air-outlet sides.Filters with activated-carbon cartridges can be installed only vertically.COPULAR air filters with, one ortwo connection fittings, areprimarily used for purification of airexhausted from glove boxes used inthe nuclear and chemical industries,and in laboratories. The highefficiencysubmicron particulate airfilter element (HEPA) cannot beexchanged.Filter classH12 / H13H12 / H13and activated carbonH13Filter size (depth x height)(mm)140 / 172 140 / 194140 / 257 140 / 27924 0 / 24 0 / 5 44 9 0 / 4 9 0 / 5 4Connection fittings for1 21 2–exchangeable filters(each)NoNoNoNoNo24PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


Round air filtersCharacteristicsPipe-attached filter installationPipe-attached filter installationPipe-attached filter installationDesignationDAHDBH, DBA, DBVDACDBCThe cartridge can be exchanged,The cartridge can be exchanged,The filter medium can beand can be used again after beingand can be used again after beingexchanged and can be used againcleaned and wetted.cleaned and wetted.after cleaning.The filter medium can be exchangedand can be used again after cleaning(except for F5).These round filters are used to purify the intake air for internal-combustion engines and for fans. Various structuraldesigns, sizes, and filter media are available, depending on the purpose of use. Weather-protection hoods areavailable for outdoor applications.Filter class (according tocomplement items installed)Filter size, depth x height (mm)Multi-stage versionsWetting agent useG213 0 / 14 018 0 / 15518 0 / 2 3 0––NoYesG2, G4 and F524 0 / 2553 6 0 / 3 0 53 6 0 / 5 0 55 0 0 / 5 0 55 0 0 / 70 5YesWith or withoutG2 –180 / 120 240 / 255180 / 180 360 / 305180 / 250 360 / 505– 500 / 505– 500 / 705No –No –PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/200925


Filter frames for wall or ceiling installationCharacteristicsDesignationWall frames for air filtersCDDCeiling air outletCGFThese wall filter frames are made ofgalvanized or stainless steel. Fourspring clamps hold the air filters tothe frame. The frames can be boltedtogether to form a filter wall.This filter housing consists of sheetsteel with powder-coat finish (colourshade RAL 9010). A shut-off flap canbe installed in the intake-air fittingat the side. The flap, which closesairtight, can be operated manuallyor electrically (as per DIN 1946, Part4). The enclosure is equipped with adevice that checks to ensure that thefilter is seated airtight. It also has apressure-gauge connection fitting,and a fitting for oil-mist passage.Various air distributors can beconnected to the CGF ceiling airoutlet by means of central of 4-pointfastenings.Filter class (according tocomplement items installed)Filter size, depth x height (mm)Multi-stage versionsWetting agent useG2 to F928 7 / 28 728 7 / 5924 9 0 / 592592 / 59272304 / 304, 304 / 609507 / 609, 609 / 609H10 to H14305 / 305 / 78 + 7457 / 457 / 78 + 7574 / 574 / 78 + 7610 / 610 / 78 + 7345 380 435318 / 318, 470 / 470587 / 587, 623/62326PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/2009


Explanation of the form of deliveryForms suppliedSymbolsFilter matFilter rollSpecial-dimension elements<strong>Air</strong>-filter roll bandBag filterFilter plate, filter cellFilter elementHigh-efficiency submicronparticulate air filter (HEPA)CartridgePackage unitImage brochureApplication brochuresProduct brochuresData & Facts and operation manuals(available only as PDF)You are on this level of our documentation structure. You can order at no chargefrom the first 3 levels as printed copies, under: info@gea-airtreatment.com.You can download all brochures as PDF files from the following Internet site:www.gea-airtreatment.com.PR-2009-0047-GB · We reserve the right to make changes without notice · Version: 02/200927


Customer proximity, sales structuresReachable always and everywhere!ABBGBIHBYCHCZCZDDD<strong>GEA</strong> KlimatechnikGmbH & Co KGA-4673 GaspoltshofenTel. +43 / 7735 / 8000-0<strong>GEA</strong> Happel Belgium N. V.B-1130 BrusselsTel. +32 / 2 / 2406161EVISS Ltd.BG-7000 RousseTel . +359 / 82 / 81000<strong>GEA</strong> KlimatechnikGmbH & Co KGRS-11070 Novi BeogradTel. +381 / 11 / 3193955<strong>GEA</strong> Klimatechnik UABLT-01141 VilniusTel. +370 / 5 / 2106060ATC Klimatec Schweiz AGCH-3065 Bolligen-StationTel. +41 / 31 / 9171919<strong>GEA</strong> LVZ, a.s.CZ-46312 LiberecTel. +420 / 48 / 5225-111<strong>GEA</strong> Klimatizace spol. s r.o.CZ-46312 LiberecTel. +420 / 48 / 5225-303<strong>GEA</strong> HappelKlimatechnik GmbHD-44625 HerneTel. +49 / 2325 / 468-00<strong>GEA</strong> HappelWieland GmbHD-44625 HerneTel. +49 / 2325 / 468-754<strong>GEA</strong> DeichmannUmwelttechnik GmbHD-36179 BebraTel. +49 / 6622 / 504-0The complete addresses are available on theInternet under: www.gea-air-eco2nomy.com.DDDKEESTFFFINGB<strong>GEA</strong> DelbagLufttechnik GmbHD-44625 HerneTel. +49 / 2325 / 468-700<strong>GEA</strong> Delbag-LuftfilterVertriebsgesellschaft mbHD-10709 BerlinTel. +49 / 30 / 43592-3<strong>GEA</strong> Klimateknik ApSDK-2610 RødovreTel . +45 / 38 / 887070<strong>GEA</strong> <strong>Air</strong> <strong>Treatment</strong>Marketing Services Int.GmbH – oficina EspañaE-28036 MadridTel. +34 / 91 / 3837701<strong>GEA</strong> Klimatechnik UABLT-01141 VilniusTel. +370 / 5 / 2106060<strong>GEA</strong> DelbagFiltration de l‘airF-77450 MontryTel. +33 / 1 / 60043355<strong>GEA</strong> Happel France sarlF-59436 Roncq CedexTel. +33 / 3 / 20689020OY TEKNOCALOR ABFIN-01300 VantaaTel. + 358 / 10 / 8201100<strong>GEA</strong> Denco Ltd.UK-HR4 8DS HerefordTel. +44 / 1432 / 277 277HHRIEISLLTLVMWENNL<strong>GEA</strong> Klimatechnika KftH-1037 BudapestTel. +36 / 1 / 4393200<strong>GEA</strong> Klima-rashladnatehnika d.o.o.HR-10000 ZagrebTel. +385 / 1 / 6064900Aspect Environmental Ltd.Ardee, Co. Louth IrelandTel. +353 / 41 / 6858983Rafn JenssonIS-110 ReykjavikTel. +354 / 56 / 780-30<strong>GEA</strong> Happel LuxembourgL-4940 BascharageTel. +352 / 26 / 502970<strong>GEA</strong> Klimatechnik UABLT-01141 VilniusTel. +370 / 5 / 2106060<strong>GEA</strong> Klimatechnik UABLT-01141 VilniusTel. +370 / 5 / 2106060<strong>GEA</strong> KlimatechnikGmbH & Co KGRS-110 70 Novi BeogradTel. +381 / 11 / 3193955<strong>GEA</strong> Klimaprodukter ASN-0484 OsloTel. +47 / 220 / 27990<strong>GEA</strong> Happel Nederland B.V.NL-2909 LLCapelle a/d IjsselTel. +31 / 10 / 2350606PPLRORUSSSKSLOSRBTRUAUAENónio, Lda.P-1269-090 LisboaTel. +351 / 21 / 3826160<strong>GEA</strong> Klimatyzacja Sp. z o.o.PL-54610 WroclawTel. +48 / 71 / 3737952<strong>GEA</strong> Klimatechnik s.r.l.RO-300222 TimisoaraTel. +40 / 356 / 423703<strong>GEA</strong> KlimatechnikGmbH & Co KGRU-105094 MoskvaTel. +7 / 495 / 9566674<strong>GEA</strong> EXOS Ventilation ABS-74528 EnköpingTel. +46 / 171 / 85530<strong>GEA</strong> Klimatizácia s.r.o.SK-83104 BratislavaTel. +421 / 7 / 44457917<strong>GEA</strong> KlimatizacijskaTehnika d.o.o.SI-1000 LjubljanaTel. +386 / 1 / 2573850<strong>GEA</strong> KlimatechnikGmbH & Co KGRS-11070 Novi BeogradTel. +381 / 11 / 3193955<strong>GEA</strong> ISISANTR-80700Balmumcu IstanbulTel. +90 / 212 / 2757171<strong>GEA</strong> Ukraina t.o.v.UA-01135 KyivTel. +38 / 044 / 4619356<strong>GEA</strong> <strong>Air</strong> <strong>Treatment</strong>Middle EastUAE-DubaiTel. +971 / 4 / 887 3881PR - 2009-0047-GB • Subject to modificationVersion 02/2009 • Copyright <strong>GEA</strong> <strong>Air</strong> <strong>Treatment</strong>www.gea-air-eco2nomy.com