DATAKOM<strong>DKG</strong>-<strong>705</strong> User’s ManualTerm Function Technical data Description11 CURR_W+Current transformer12 CURR_W-inputs, 5A-AC13 CURR_V+14 CURR_V-15 CURR_U+16 CURR_U-Connect the generator current transformerterminals to these inputs. Do not connect thesame current transformer to other units than<strong>DKG</strong>-<strong>705</strong> otherwise a unit fault will occur.Connect each terminal of the transformer tothe unit’s related terminal. Do not usecommon terminals. Do not use grounding.Correct polarity of connection is vital. If themeasured power is negative, then change thepolarity of each 3 current transformers. Therating of the transformers should be the samefor each of the 3 phases. The secondarywinding rating shall be 5 Amperes. (For ex.200/5 Amps).17 HIGH TEMP. SENSOR Input, 0-5000 ohms Analogue high temperature sensorconnection. Do not connect the sensor toother devices.18 OIL PRESSURE SENSOR Input, 0-5000 ohms Analogue oil pressure sensor connection. Donot connect the sensor to other devices.19 FUEL LEVEL SENSOR Input, 0-5000 ohms Analogue fuel level sensor connection. Do notconnect the sensor to other devices.20 OIL TEMP. SENSOR Input, 0-5000 ohms Analogue oil temperature sensor connection.Do not connect the sensor to other devices.Term Function Technical data Description21 PROGRAM LOCK Digital input This input is used to prevent unwantedmodification to programmed values. If thisinput is left open, program values can bemodified via the front panel buttons, but if thisinput is connected to battery- it will not bepossible to change the program values.22 DIGITAL INPUT-723 DIGITAL INPUT-624 DIGITAL INPUT-525 DIGITAL INPUT-426 DIGITAL INPUT-327 DIGITAL INPUT-228 DIGITAL INPUT-129 DIGITAL INPUT-0Digital inputsThese inputs have programmable functions,selectable from a list via the program menu.Each input may be driven by a ‘normallyclosed’ or ‘normally open’ contact, switchingeither battery+ or battery-. The effect of theswitch is also selectable from a list. SeePROGRAMMING section for more details.<strong>705</strong>-UE.doc - 7 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!