DATAKOM<strong>DKG</strong>-<strong>705</strong> User’s ManualProgram Group: 10This group of programs defines the No Break Transfer and Parallel with Mains featurecharacteristics.This group is reserved for factory and qualified installation personal andmust not be modified by end users or non-qualified service personal.Otherwise severe damage may occur.Group Param. Definition Unit Min Max Description10 A00 No Break Transfer - 0 1 0: No break transfer disabled.1: No break transfer enabled.10 A01 Soft TransferEnable- 0 1 0: Soft transfer disabled.1: Soft transfer enabled.10 A02 GOV Control - 0 1 0: Governor control disabled.Enable10 A03 GOV ReversePolarity10 A04 AVR ControlEnable10 A05 AVR ReversePolarity10 A06 Ignore PhaseOrder10 A07 SynchronizationFail Timeout10 A08 Soft TransferTimer10 A09 ContactorTimeout10 A10 Max FrequencyDifference10 A11 Max VoltageDifference1: Governor control enabled.- 0 1 0: Governor control normal polarity (speedincreases with voltage increase).1: Governor control reverse polarity (speeddecreases with voltage increase).- 0 1 0: AVR control disabled.1. AVR control enabled.- 0 1 0: AVR control normal polarity (voltageincreases with resistor decrease).1: AVR control reverse polarity (voltagedecreases with resistor decrease).- 0 1 0: Phase order check enabled. This option isused in 3 phase gensets.1: Phase order check disabled. This option isused in single phase gensets.Sec. 0 60 If the phase and voltage synchronization is notsuccessful before the expiration of this timer,then a Synchronization Fail Warning is givenand the <strong>DKG</strong>-<strong>705</strong> renounces the No BreakTransfer and makes a conventionalchangeover.Sec. 0 60 This is the time duration of the Soft Transfer.At the end of this timer one of the contactorswill release to terminate the parallel operation.Sec. 0 5 This is the maximum time duration in whichboth contactors are active in case of No BreakTransfer. It is advised to set this timer to0.5sec.Hz 0.1 2.0 This is the maximum difference between mainsand genset frequencies to enable a NO BreakTransfer. Note that the <strong>DKG</strong>-<strong>705</strong> adjusts theGOV output to bring the genset to the samefrequency with the mains.V 0 20 This is the maximum difference between themains phase-R and the genset phase-Uvoltages to enable a NO Break Transfer. Notethat the <strong>DKG</strong>-<strong>705</strong> adjusts the AVR output tobring the genset to the same voltage with themains.<strong>705</strong>-UE.doc - 48 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!