12.07.2015 Views

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DATAKOM<strong>DKG</strong>-<strong>705</strong> User’s ManualNo: FUNCTION000 Choke Relay001 Preheat Relay002 Start Relay003 Alarm Relay (timed)004 Generator Contactor Relay005 Mains Contactor Relay006 Fuel Relay007 Stop Relay008 Load Shedding Relay009 Alarm Relay (without timeout)010 Load Contactor relay for dual011 Auto ready012 Master request relay for dual013 not used014 not used015 not used016 Shutdown: Digital Input_0017 Shutdown: Digital Input_1018 Shutdown: Digital Input_2019 Shutdown: Digital Input_3020 Shutdown: Digital Input_4021 Shutdown: Digital Input_5022 Shutdown: Digital Input_6023 Shutdown: Digital Input_7024 not used025 Shutdown: Gen Under-Frequency026 Shutdown: Gen Over Frequency027 Shutdown: High Battery Voltage028 Shutdown: Low Fuel Level029 Shutdown: High Oil Te mp. Mea.030 Shutdown: High Temp. Measured031 Shutdown: Low Oil Pressure Mea.032 Shutdown: Fail To Stop033 Shutdown: Fail To Start034 Shutdown: Genset Low Voltage035 Shutdown: Genset High Voltage036 Shutdown: Slave not available037 Shutdown: Gen phase seq. fail038 Shutdown: Low Engine Speed039 Shutdown: High Engine Speed040 Shutdown: not used041 Shutdown: not used042 Shutdown: not used043 Shutdown: not used044 Shutdown: not used045 Shutdown: not used046 Shutdown: Communication lost047 Shutdown: not used048 Load Dump: Digital Input_0049 Load Dump: Digital Input_1050 Load Dump: Digital Input_2051 Load Dump: Digital Input_3052 Load Dump: Digital Input_4053 Load Dump: Digital Input_5054 Load Dump: Digital Input_6055 Load Dump: Digital Input_7No: FUNCTION056 Load Dump: not used057 Load Dump: not used058 Load Dump: not used059 Load Dump: not used060 Load Dump: not used061 Load Dump: Gen Reverse Power062 Load Dump: Gen Excess Power063 Load Dump: Alternator Overcurr.064 Load Dump: not used065 Load Dump: not used066 Load Dump: not used067 Load Dump: not used068 Load Dump: not used069 Load Dump: not used070 Load Dump: not used071 Load Dump: not used072 Load Dump: not used073 Load Dump: not used074 Load Dump: not used075 Load Dump: not used076 Load Dump: not used077 Load Dump: not used078 Load Dump: not used079 Load Dump: not used080 Warning: Digital Input_0081 Warning: Digital Input_1082 Warning: Digital Input_2083 Warning: Digital Input_3084 Warning: Digital Input_4085 Warning: Digital Input_5086 Warning: Digital Input_6087 Warning: Digital Input_7088 Warning: Synchronization Fail089 Warning: Gen Under-Frequency090 Warning: Gen Over-Frequency091 Warning: High Battery Voltage092 Warning: Low Fuel Level093 Warning: High Oil Temp. Mea.094 Warning: High Temp. Measured095 Warning: Low Oil Pressure Mea.096 Warning: Mains Phase Seq. Fail097 Warning: not used098 Warning: Charge Failure099 Warning: Low Battery Voltage100 Warning: AVR Control Fail101 Warning: GOV Control Fail102 Warning: Low Engine Speed103 Warning: High Engine Speed104 Warning: Mains Fail at Parallel105 Warning: Mains Reverse Power106 Warning: Mains Freq. Failure107 Warning: No Mains Frequency108 Warning: ROCOF (df/dt) Failure109 Warning: Vector Shift (df/dt) Fail110 Warning: Communication lost111 Warning: not used<strong>705</strong>-UE.doc - 46 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!