DATAKOM<strong>DKG</strong>-<strong>705</strong> User’s ManualProgram Group 4Group Parameter Definition Min Max Description4 400, 402,404,406,408, 410,412, 4144 401, 403,405,407,409, 411,413, 415Turn_on - - Weekly schedule turn_on times. The day andtime information is defined in 15 minute steps.Turn-off - - Weekly schedule turn-off times. The day andtime information is defined in 15 minute steps.4 416-431 Telephone number #1 - - Each program parameter changes one digit ofthe first telephone number. The parameter 416points to the first digit of the number, theparameter 417 points to the second digit etc…Non-numeric characters will be skipped.4 432-447 Telephone number #2 - - Each program parameter changes one digit ofthe second telephone number. The parameter432 points to the first digit of the number, theparameter 433 points to the second digit etc…Non-numeric characters will be skipped.Program Group 5Group Parameter DefinitionUnit Min Max Description5 500 Wait before Fuel Min. 0 240 This is the time between the mains failsand the fuel solenoid turns on for startingthe genset.5 501 Wait before Start Sec 0 30 This is the time after the fuel solenoid isenergized and before the genset isstarted. This will be the preheat period ifglow plugs are used.5 502 Wait between Starts Sec 1 30 This is the waiting period between twostart attempts.5 503 Start Timer Sec 1 15 This is the maximum start period. Startingwill be automatically cancelled if thegenset fires before the timer.5 504 Start Attempts - 1 6 This is the maximum number of startattempts.5 505 Stop Timer Sec 0 90 This is the maximum time duration forthe engine to stop. For Activate to Stoptype engines this will be the periodduring which the stop solenoid isenergized. If the genset has not stoppedafter this period, a FAIL TO STOP alarmwill occur.5 506 Mains Waiting Timer Min. 0.0 60.0 This is the time between the mainsvoltages and frequency entered within thelimits and the generator contactor isdeactivated.5 507 Cooling Timer Min. 0.0 30.0 This is the period that the generator runsfor cooling purpose after the load istransferred to mains.5 508 Mains Contactor Timer Sec 0.5 15.0 This is the period after the generatorcontactor has been deactivated andbefore the mains contactor has beenactivated.<strong>705</strong>-UE.doc - 36 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!