12.07.2015 Views

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DATAKOM<strong>DKG</strong>-<strong>705</strong> User’s Manual17. PROGRAMMINGThe programming mode is used to program the timers, operational limits and the configuration of theunit. The programming mode is protected by a 3 level password system.To enter the program mode, press the PGM button. The program mode will not affect the operationof the unit. Thus programs may be modified anytime, even while the genset is running.If no button is pressed during 1 minute the program mode will be cancelled automatically.Upon pressing the PGM button the unit will ask the password to be entered. Enter the passwordusing ? (UP) and ? (DOWN) buttons. Holding the button pressed will cause a fast scroll of the valueenabling quick operation.When the desired password is entered, press MENU button. This will cause the first programparameter to appear.The program menu is organized as program groups, each group including a set of parameters.Each depression of the MENU button will cause the current program parameter to be stored to thenon-volatile memory if modified; and the display to switch to the next program parameter in the currentgroup if the current parameter is not modified. This means that after modification, the MENU key should bepressed twice to switch to the next parameter. After the last parameter, the display switches back to thefirst parameter.The displayed program parameter may be modified using ? (UP) and ? (DOWN) buttons.The program value modification is only allowed if the PROGRAM LOCK input (terminal_21) is leftopen. If this input is tied to GROUND, the program value modification will be disabled to preventunauthorized intervention. It is advised to keep the PROGRAM LOCK input tied to GROUND.If the MENU button is held pressed for 1 second, the display will switch to the next program group.Each password is a number between 0 and 65535. They will allow different levels of programmodification.Level Definition Factory set Description1 Service password 1 Allows the modification of service parameters.2 Factory password 2 Allows the modification of factory set parameters and serviceparameters.3 Production password 3 Allows the modification of all parameters, including the operationmode and calibration.Programmed values are stored in a Non Volatile Memory, which is not affected by energy failures. ToEXIT programming, press the PGM button.<strong>705</strong>-UE.doc - 34 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!