DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DATAKOM<strong>DKG</strong>-<strong>705</strong> User’s Manual4.3 WarningsDefinition Source DescriptionLow Oil Press.Switch Digital Input These warnings are set depending on the digital input settings. TheHigh Eng.Temp.Switch Digital Input related program parameters are P_700 to P_776.Emergency Stop Digital InputLow Coolant Level Digital InputAlternator High Temp. Digital InputHigh Oil Temp. Digital InputOverloadDigital InputLow Fuel Level Digital InputBattery Charger Fail Digital InputSpare Alarm 7Digital InputSpare Alarm 6Digital InputSpare Alarm 5Digital InputSpare Alarm 4Digital InputSpare Alarm 3Digital InputSpare Alarm 2Digital InputSpare Alarm 1Digital InputSynchronization Fail Internal Set if the phase and voltage synchronization is not successfulbefore the expiration of Synchronization Fail Timeout (P_A07).Gen Under-Frequency Phase-U Set if the genset frequency goes under the Low FrequencyWarning (P_517) limit for Frequency Timer (P_520) period.Gen Over-Frequency Phase-U Set if the genset frequency goes over the High FrequencyWarning (P_519) limit for Frequency Timer (P_520) period.High Battery Voltage Internal Set if the battery voltage goes over the High Battery VoltageWarning (P_611) limit.Low Fuel Level AnalogInputSet if the fuel level measured from analog input goes under the LowFuel Level Warning (P_609) limit.High Oil Temperature AnalogInputSet if the oil temperature measured from analog input goes over theHigh Oil Temperature Warning (P_607) limit.High CoolantTemperatureAnalogInputSet if the coolant temperature measured from analog input goesover the High Coolant Temperature Warning (P_605) limit.Low Oil PressureMeasuredAnalogInputSet if the oil pressure measured from analog input goes under theLow Oil Pressure Warning (P_603) limit.Mains Phase SequenceFailR-S-T Set if the mains phase sequence is not correct and Ignore PhaseOrder (P_A06) parameter is ‘0’.Charge Failure ChargeinputSet if the Charge input (terminal_31) is pulled to battery negativewhen the engine is running.Low Battery Voltage Internal Set if the battery voltage goes under the Low Battery VoltageWarning (P_612) limit.AVR Control Fail Internal Set if the AVR control output has gone to the low or high limitvalue for 1 second.GOV Control Fail Internal Set if the GOV control output has gone to the low or high limitvalue for 1 second.Low Engine Speed MagneticPickupSet if the engine rpm goes under the Low rpm Warning (P_614)limit. If the Crank Teeth Count (P_619) is set to ‘0’, this warning willHigh Engine SpeedMagneticPickupbe disabled.Set if the engine rpm goes over the High rpm Warning (P_616)limit. If the Crank Teeth Count (P_619) is set to ‘0’, this warning willbe disabled.<strong>705</strong>-UE.doc - 16 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!