Page 12Possible error messages:1.L I F T N O T I N P O S I T I O NP R E S S S T O P B U T T O NF O R S T A R T P O S I T I O NThe lift is not in the start position (top limit switch). The lift can be moved tostart position using the Stop button.2.C A S I N G C O V E R O P E NThe lid must be closed. The process can only be started with thelid closed.3.3 STOP button:When the process is running, pressing the Stop button terminates the process and thesystem automatically returns to the start position (heater is shut down; gate is opened; liftmoves up; gate is closed).If the process is terminated by pressing the Power button, the lift and the gate can bemoved manually to the start position by keeping the Stop button pressed.Cooper Tools GmbHCarl-Benz-Str. 2, 74354 Besigheim, GermanyTel: 07143/580-0; Fax 07143/580-108www.cooperhandtools.com/europe