12.07.2015 Views

0 DB MB-DLE 415-420 B01 GB - Boiler.com.sg

0 DB MB-DLE 415-420 B01 GB - Boiler.com.sg

0 DB MB-DLE 415-420 B01 GB - Boiler.com.sg

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GasMultiBlocCombined regulator andsafety shut-off valvesSingle-stage function<strong>MB</strong>-D(LE) <strong>415</strong>-<strong>420</strong> <strong>B01</strong>7.02Printed in Germany • Rösler Druck • Edition 08.00 • Nr. 225 7581 … 6Technical descriptionThe DUNGS GasMultiBloc integrates filter,regulator, valves and pressure switchesin one <strong>com</strong>pact fitting. Various designsare possible by the modular system:- Dirt trap: microfilter- One regulator and two valves: <strong>B01</strong>- Two valves are fast opening- One valve is fast opening and one valveis slow opening- Solenoid valves up to 360 mbar as perDIN EN 161 Class A Group 2- Sensitive setting of output pressure byproportional regulator as per DIN EN88 Class A Group 2- High flow rates with low pressure drop- DC solenoid drive interference degree N- Main volume restrictor at valve V2- Hydraulic opening delay- Flange connections with pipe threadsas per ISO 7/1- Simple mounting, <strong>com</strong>pact, light-weightThe modular system permits individualsolutions by using external ignition gas tapin connection with separately controlledvalves, by adding a valve proving system,mini/maxi pressure switches, pressurelimiters, limit switch at valve V2.ApplicationThe modular system permits individualsolutions in gas safety and regulator engineering.Suitable for gases of families 1, 2,3 and other neutral gaseous media.ApprovalsEU type test approval as per EU GasAppliance Directive.<strong>MB</strong>-D(LE) <strong>415</strong> <strong>B01</strong> CE-0085 AR 0233<strong>MB</strong>-D(LE) <strong>420</strong> <strong>B01</strong> CE-0085 AR 0233Approvals in other important gas-consumingcountries.


Equipment variantsGasMultiBloc...<strong>B01</strong>Single-stage function<strong>MB</strong><strong>MB</strong>-D<strong>MB</strong>-<strong>DLE</strong><strong>MB</strong>-LEMicrofilterGas pressure switchdownstream of filterdownstream of valve V2 on adapterPressure regulatorValve V1, double seatValve V2, double seatValves opening togetherValves opening separatelyFlange Rp 1Rp 1 1/4Rp 1 1/2Rp 2<strong>415</strong> <strong>B01</strong>••••••••••••••••<strong>420</strong> <strong>B01</strong>••••••••••••••••Filter element can be removed. A suitable GF.../1gas filter must then be fitted upstream.• = possible(•) = on request- = not possible<strong>MB</strong>-...<strong>B01</strong> versionV1 = Valve 1V2 = Valve 23 = Filter4 = Pressure switch, optional5 = RegulatorMounting of VPS 504 valve proving system possibleMounting of K01/1 closed position signal contact possible34V1 5 V2For further information, refer to Datasheet 7.04: GasMultiBloc Modular System, Accessories, Additional equipmentType key of MultiBloc<strong>MB</strong>- XX XXX XX BOX SXXControl of V1 and V20 = <strong>com</strong>mon2 = separatedOutlet pressure Inlet pressure2 = 4 - 20 mbar up to 360 mbar5 = 20 - 50 mbar up to 360 mbarS = Series (type-independent)Gas train schematic diagram1 = two A valves for main gas + regulator2 = two A valves for main gas7 = two A valves for main gas, one A valve togetherwith V1 as internal bypass around V2 + regulatorDesign type (generation) BConstruction size, nominal diameter403 = DN 10, V2 = Single-seat valve405 = DN 15, V2 = Single-seat valve407 = DN 20, V2 = Double-seat valve410 = DN 25, V2 = Single-seat valve412 = DN 32, V2 = Double-seat valve<strong>415</strong> = DN 40, V2 = Double-seat valve<strong>420</strong> = DN 50, V2 = Double-seat valveOpening behaviour + main volume restrictorwithout = (<strong>MB</strong> or <strong>MB</strong>-ZR)-D = Main volume restrictor-LE = adjustable opening behaviour-<strong>DLE</strong> = D + LE <strong>com</strong>binationwithout = single stageZR = double-stage with partial volume settingfirst stageMultiBloc4 … 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!