1 Electronic Flow Meter FC01 - FlowVision GmbH

1 Electronic Flow Meter FC01 - FlowVision GmbH 1 Electronic Flow Meter FC01 - FlowVision GmbH

flowvisiongmbh.de
from flowvisiongmbh.de More from this publisher
12.07.2015 Views

123456712132435465768791223341526371234567121324354657687912233415263788888888888Electronic Flow Meter FC01Connection diagramsFC01 with relay outputs1DGND brown/LIM2LifYCY 3x0.35 mm 2LIM2COM LifYCY 3x0.38 mm 2 *SGND blackFRIN whiteLIM2turbine type sensorUBFR greenSGNDL2/LIM1LIM1COM LifYCY 3x0.38 mm 2 * signal outputs}LIM1SGNDL1R(Tdiff)-HI pinkR(Tdiff)-LO greyANA2GND LifYCY 2x0.25 mm 2 *SGND blackANAO2SGNDA2analogueLifYCY 4x2x0.2 mm 2ISredSGNDA1ANA1GND LifYCY 2x0.25 mm 2 * outputs}AGND blueC1, V1, V2 **calorimetricR(Tref)-LO whiteANAO1monitoring headR(Tref)-HIR(HEIZ)-HIbrowngreenyellowR(HEIZ)-LO * recommended** Apply shield on one side onlyrecommended:(0V) blue(+24 V)3x0.75 mm brownGND yellow/ greeninput voltage1 410321XV XSK XTF XSFXAS XAO XAHFC01 with transistor outputs(+24 V) brownSGNDDGND brownLIM1 C/ +LifYCY 3x0.35 mm 2SGND blackLIM1 E/ -FRIN whiteLIM2 C/ +turbine type sensorUBFR greenE/ -BUSY/PULSE C/+BUSY/PULSE E/ -ERROR C/ +ERROR E/ -R(Tdiff)-HI pinkR(Tdiff)-LO greyANA2GNDSGND blackANAO2SGNDA2LifYCY 4x2x0.2 mm 2ISAGNDredblueSGNDA1ANA1GNDcalorimetricR(Tref)-LO whiteANAO1monitoring headR(Tref)-HIR(HEIZ)-HIbrowngreenR(HEIZ)-LO yellowrecommended:3x0.75 mm 2 (0V) blueGND yellow/ greeninput voltage1 410321XV XSK XTF XSFXAS XAO XAH**LIM2 LifYCY 4x2x0.2 mm 2 *signal outputsLifYCY 2x0.25 mm 2 *analogueLifYCY 2x0.25 mm 2 * outputs} V1, V2, C1**** recommended** E/ - emitter terminalC/ + collector terminal*** Apply shield on one side only.FC01 - Recommended connection of pulse outputElectronic signal processingElectromagnetic pulse counterXAS XAO XAHXAS XAO XAH1234567123456712345671234567123456712345678Zener voltagei Ct L t ON tU CU Vi L ≤ 10 mAU VU Ci CU V

FC01 - Monitoring head CSTDescriptionThread-mounted calorimetric monitoring headThread-mounted calorimetric monitoring head for Flow Meter FC01,suitable for general industry applications.Features● Suitable for installation in welding bushes● Medium temperature -40 °C...+130 °C● Material: stainless steel 1.4571/AISI 316 Ti,or Hastelloy alloy C4 2.46101CST-...Ordering informationTechnical dataType No.CST Thread-mounted monitoring head with calorimetric sensorsProcess connection01 thread size G1/2A (FC01-standard)MediumA airW waterMaterial of areas exposed to mediumM1 stainless steel 1.4571/AISI 316 Ti (standard)M2 nickel-based alloy Hastelloy alloy C4 2.4610Length of shank/threadL10 36 mm (standard)Electrical connectionE10 round connector with tinned contacts(plug and cable to separate order)CertificationT0 without certificate (standard)*)Specification of mediumxxxCST - 01 W M1 L10 E10 T0 - ... ordering example*) for detailed information please see section 0.DimensionsType of headNominal thread dia.Length of shankLength of sensorSuitable forthread-mountedG1/2A36 mm14 mmall media, depending onmaterial resistanceTemperatue range *) -40...+130 °C(of medium)Temperature drift± < 0.05 %/°K/measuring rangeof monitoring head (in the range between +20 °C and +80 °C)Measuring ranges air: 0...20 m/swater: 0...3 m/sPressure resistance (1) 100 bar / 1470 PSIDegree of protection connector (2) : IP67Materialstainless steel 1.4571/AISI 316 TiHastelloy alloy C4 2.4610Cable to LifYCY 4x2x0.2 mm 2 (AWG 24)electronic control unit(1) Admissible operating pressure DIN 2401, measured at max. temperature(= max. medium temperature)(2) with mating connector*) max. +85 °C in the connector area1/2-14NPTG1/2A14361.4220.787361.42.55114.551BøASW271.06 in.SW271.06 in.round connectorG1/2AøAmm inch18 .709Bmm inch10 .394This is a metric design and millimeter dimensions take precedence ( mm )inchIssue A(010108)www.e-t-a.com 1 - 55

123456712132435465768791223341526371234567121324354657687912233415263788888888888<strong>Electronic</strong> <strong>Flow</strong> <strong>Meter</strong> <strong>FC01</strong>Connection diagrams<strong>FC01</strong> with relay outputs1DGND brown/LIM2LifYCY 3x0.35 mm 2LIM2COM LifYCY 3x0.38 mm 2 *SGND blackFRIN whiteLIM2turbine type sensorUBFR greenSGNDL2/LIM1LIM1COM LifYCY 3x0.38 mm 2 * signal outputs}LIM1SGNDL1R(Tdiff)-HI pinkR(Tdiff)-LO greyANA2GND LifYCY 2x0.25 mm 2 *SGND blackANAO2SGNDA2analogueLifYCY 4x2x0.2 mm 2ISredSGNDA1ANA1GND LifYCY 2x0.25 mm 2 * outputs}AGND blueC1, V1, V2 **calorimetricR(Tref)-LO whiteANAO1monitoring headR(Tref)-HIR(HEIZ)-HIbrowngreenyellowR(HEIZ)-LO * recommended** Apply shield on one side onlyrecommended:(0V) blue(+24 V)3x0.75 mm brownGND yellow/ greeninput voltage1 410321XV XSK XTF XSFXAS XAO XAH<strong>FC01</strong> with transistor outputs(+24 V) brownSGNDDGND brownLIM1 C/ +LifYCY 3x0.35 mm 2SGND blackLIM1 E/ -FRIN whiteLIM2 C/ +turbine type sensorUBFR greenE/ -BUSY/PULSE C/+BUSY/PULSE E/ -ERROR C/ +ERROR E/ -R(Tdiff)-HI pinkR(Tdiff)-LO greyANA2GNDSGND blackANAO2SGNDA2LifYCY 4x2x0.2 mm 2ISAGNDredblueSGNDA1ANA1GNDcalorimetricR(Tref)-LO whiteANAO1monitoring headR(Tref)-HIR(HEIZ)-HIbrowngreenR(HEIZ)-LO yellowrecommended:3x0.75 mm 2 (0V) blueGND yellow/ greeninput voltage1 410321XV XSK XTF XSFXAS XAO XAH**LIM2 LifYCY 4x2x0.2 mm 2 *signal outputsLifYCY 2x0.25 mm 2 *analogueLifYCY 2x0.25 mm 2 * outputs} V1, V2, C1**** recommended** E/ - emitter terminalC/ + collector terminal*** Apply shield on one side only.<strong>FC01</strong> - Recommended connection of pulse output<strong>Electronic</strong> signal processingElectromagnetic pulse counterXAS XAO XAHXAS XAO XAH1234567123456712345671234567123456712345678Zener voltagei Ct L t ON tU CU Vi L ≤ 10 mAU VU Ci CU V

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!