28.11.2012 Views

IBM Tivoli NetView for z/OS Programming: Pipes - IBM notice

IBM Tivoli NetView for z/OS Programming: Pipes - IBM notice

IBM Tivoli NetView for z/OS Programming: Pipes - IBM notice

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Full-Screen Automation<br />

328 <strong>Programming</strong>: <strong>Pipes</strong><br />

BNH150I FIELDS/CURRENT OUTPUT FOR ’HELP’ RECEIVED FROM HELP.<br />

BEEP 24.13<br />

1.1 FA IN CB HD % CNMKNCCF<br />

1.28 FA IH CW HD % COMMAND FACILITY HELP MENU<br />

2.1 FA IN CT HD %<br />

3.1 FA IN CT HD %<br />

4.1 FA IH CT HU % Select<br />

4.8 FA IN CB HD % To get in<strong>for</strong>mation about<br />

5.1 FA IN CT HD %<br />

6.1 FA IN CT HD %<br />

6.4 FA IH CW HD % 1<br />

6.9 FA IN CT HD % Operator’s overview of the command facility<br />

7.1 FA IN CT HD %<br />

7.4 FA IH CW HD % 2<br />

7.9 FA IN CT HD % Using the terminal access facility (TAF)<br />

8.1 FA IN CT HD %<br />

9.1 FA IN CT HD %<br />

9.4 FA IH CW HD % 3<br />

9.9 FA IN CT HD % The command facility screen<br />

10.1 FA IN CT HD %<br />

10.4 FA IH CW HD % 4<br />

10.9 FA IN CT HD % Command facility commands and command lists<br />

In this case, line 4 shows that the word Select is in turquoise and underscored.<br />

Other Messages<br />

A full-screen automation program must be able to handle BNH150I and other<br />

returned messages from VET NEXT and VET CURRENT.<br />

For example, you might try to ATTACH a V<strong>OS</strong>T and run a command that does not<br />

display a full-screen. Messages that result from the command being entered on an<br />

end-user screen are returned to the full-screen application.<br />

If both a full-screen and messages are presented by the application running on the<br />

V<strong>OS</strong>T, a VET first stage presents both BNH150I and other messages to the output<br />

stream. The order in which these messages are presented depends on how the<br />

application generates them. For example, if the application first issues two<br />

messages and then presents a full screen, the messages are returned to VET first,<br />

then BNH150I with the full-screen in<strong>for</strong>mation. However, if the application<br />

presents a full screen and then messages, the messages are held until the<br />

full-screen portion of the application terminates. Only after the full screen<br />

terminates are the messages returned to VET.<br />

In the example shown in Figure 21 on page 329, message BNJ924I is returned from<br />

a VET NEXT ROWS in addition to BNH150I containing the NPDA-01A panel.<br />

NPDA-01A and BNJ924I resulted from ATTACH NPDA SD NODOM.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!