12.07.2015 Views

DOOR CONTROL COLLECTION 2013 - Architectural Hardware Direct

DOOR CONTROL COLLECTION 2013 - Architectural Hardware Direct

DOOR CONTROL COLLECTION 2013 - Architectural Hardware Direct

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ContentsDCF20036DCC2003CF17DCT20247DCC2024CF/3618DCS20248DCFS150/EN3DCFS250/EN420DCS20259DCTS100/EN3DCTS150/EN421DCS202610H2N1900H2N195022DCC2024SM13DCCEM302424DCC2003SM14DCEM200325DCC2024SM/3615DCEM200426DCC2024CF16AA45, CDC85SC/RCDG003291


MECHANICALMECHANICALKey to Finishes and SymbolsBS EN 1154:1996 Explained...FinishesBSSCPEBBright Stainless SteelPolished ChromeElectro BrassPCPNPPVDPolished ChromePolished Nickel PlateStainless BrassSSSSVWHTSatin Stainless SteelSilverWhiteBS EN 1154:1996 is the European standard for controlled door closing devices and, as such, tests mechanical door closer performance.Adopted by EU member states, it became a mandatory requirement for CE marking in 2004. It prescribes the test methodology and subsequent classificationof randomly selected production line products. The test data, together with supporting technical evaluation, results in a classification code.This coding allows comparison across a range of closers according to their compliance with the standard.Door closers for fire doors are covered by a Constructive Products <strong>Direct</strong>ive mandate. Compliance with BS EN 1154:1996, supported by suitable evidence,therefore allows the application of the CE mark. All conforming door closers consequently will be marked with their BS EN 1154:1996 coding and details of thenotified certification body.EBPElectro Brass PlateSCSatin ChromeDoor controls with electrical components, such as electromagnetic hold open devices, must also satisfy the requirements of both BS EN 1154:1996 and thesupplementary standard, BS EN 1155:1997 for electrically controlled door operators.PBPolished BrassSNPSatin Nickel PlateSymbolsAPPROVED PRODUCTCertifire is an independent 3rd party scheme providing high quality, voluntary,product conformity for the passive fire sector. The requirements are based onthose of CE marking, but whereas the CE mark reflects compliance with minimumregulatory requirements Certifire is product certification at a higher level.Additional requirements are ISO9001:2008 certification, independent audit testingand a comprehensive field of application document based on carefully chosentests. Designed to give confidence to specifiers, enforcement authorities andbuilding owners/occupiers, the Certifire scheme is recognised by regulatoryauthorities both in the UK and overseas.ELyrGUARANTEEGUARANTEEE CTR ICALyryr10 Year Mechanical Guarantee2 Year Mechanical Guarantee2 Year Electrical GuaranteeDoor Size/MassThe number identifies the power size of the closer as defined by thedoor size and mass. Adjustable power closers are defined by the upperand lower power sizes.Closer SizeMax Door SizeGUARANTEECE Marking is certification to the highest levels of attestation required bythe Construction Products <strong>Direct</strong>ive. The CE mark indicates that theproduct has been successfully 3rd party performance/fire tested and thatthe producing factory has passed stringent Factory Production Controlaudits, carried out by a UKAS notified certification body.BS EN 1154BS EN 1155British/European standardrequirements and testingmethods covering controlleddoor closing devices.British/European standardrequirements and testing methodscovering electrically powered holdopen devices for swing doors.FD30FD30/60 FD60 FD30/60/120 FD120/240BS 8300 is the design of buildingsand their approaches to meet theBS EN 1634 PART1:2000 European Fire Safety standard for determining the fire resistanceof door and shutter assemblies, including door hardware. FD30 (30 Minute Fire Doors) FD60(60 Minute Fire Doors) FD120 (120 Minute Fire Doors)FD120 (120 Minute Metal Fire Doors)FD240 (240 Minute Metal Fire Doors).The UK Construction Products <strong>Direct</strong>ive requires thatdoor hardware for use on fire doors be safe and durable. It is recommended that doorhardware fitted to fire doors should be CE marked.needs of disabled people.NOTE: BS 8300 Requirements are for thewhole door set and therefore theminimum width of suitable door willincrease when the door is fitted with allother items of ironmongery on site.Category of UseDefines the angle from which the closer will close the door ina controlled manner. Grade 3 will control the door from 105°.Most Carlisle Brass closers will operate from 180° - Grade 4.Test CyclesIncluded in a 500,000 cycle test as defined by Grade 8 the only gradeavailable.1 750mm - 20Kg2 850mm - 40Kg3 950mm - 60Kg4 1100mm - 80Kg5 1250mm - 100Kg6 1400mm - 120Kg7 1600mm - 160Kg4 8 3 1 1 3Corrosion ResistanceA salt spray test is used toascertain corrosion resistancethereby establishing suitability foruse in varying environmentalconditions. Five grades areidentified from 0 (no identifiedresistance) to 4 (very highresistance). All Carlisle Brassclosers achieve at least Grade 3and are suitable for use in wet,polluted environments and mostexterior applications.SafetyThe part of the standard which ensures the operation andsuitability of the closer is hazard free. It provides peace ofmind that the closer operates without risk to the user.Only Grade 1 is identified.Suitable Environments for UseFire BehaviourBased on the results of fire testing to BS EN 1634 ensuringthe door remains closed under temperatures which canexceed 1000°C. Grade 1 is for closers which are deemedsuitable for use on fire doors. Grade 0 are not suitable foruse on fire doors.Housing/DomesticOffice/RetailCommercialHospitals/Government Education Sports Stadia/Institution2 3


Select the Correct Door Closer For Your ApplicationWhich Door Closer?Entry Closers forGeneral ApplicationsMedium FrequencyCommercial ApplicationsHigh FrequencyCommercial ApplicationsFixed RangeVariable Position Template RangeVariable Position Spring RangeDCF2003SVDCF2003SVDCS2024-2026CDG003Jamb Mounted RangeDCT2024High Efficiency Slide ChannelConcealed and SurfaceMounted RangeDCC2003CF-DCC2024SMAA45DCS2024-2026Electromagnetic RangeCDC85SC/RDCC2003CF-DCC2024SMDCEM2003-DCEM3024Transom Closers RangeFloor Springs RangeDCTS100/EN3-DCTS150/EN4DCFS150/EN3-DCFS250/EN44 5


MECHANICALMECHANICALDCF2003Overhead Door Closer Fixed Power Size 3DCT2024Overhead Door Closer Variable Power Size 2-41121-CPD-AD01961121-CPD-AD01961121-CPD-AD01971121-CPD-AD0197BS EN 1154:1996 - Fig 1 FittingBS EN 1154:1996 - Fig 6 FittingBS EN 1154:1996 - Fig 1 FittingBS EN 1154:1996 - Fig 6 Fitting4 8 3 1 1 34 8 3 1 1 34 8 4 1 1 324 8 3 1 1 3APPROVED PRODUCTCF646APPROVED PRODUCTCF646BS EN 1154BS EN 1154FD30/60/120FD30/60/120yrGUARANTEEyrGUARANTEE17The Home of Quality <strong>Architectural</strong> Ironmongery4217864305263Torque (Nm)50403020Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)Efficiency %: 70Max Opening 0°- 4° (Nm): 29.26Max Opening 0°- 60° (Nm): 29.63Max Closing 4° - 0° (Nm): 20.58Max Closing 92° - 88° (Nm): 11.6420740554065 78Torque (Nm)50403020Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)Efficiency %: 60%Max Opening 0°- 4° (Nm): 30.37Max Opening 0°- 60° (Nm): 30.37Max Closing 4° - 0° (Nm): 18.25Max Closing 92° - 88° (Nm): 10.1710100 30 6090120 150Door Angle (°)1800 30 6090120 150Door Angle (°)180The DCF2003 overhead door closer has an opening force (0-30°) less than 30N whenfitted to a minimum width door of 926mm, and has an opening force (30-60°) less than 22.5Nwhen fitted to a minimum width door of 838mm tested in laboratory conditions. Thereforethe suitable width of door for the DCF2003 overhead door closer fixed in the above fixingposition is 926mm.The DCT2024 & DCT2024BC overhead door closer has an opening force (0-30°) less than 31Nwhen fitted to a minimum width door of 948mm, and has an opening force (30-60°) less than22.5N when fitted to a minimum width door of 838mm tested in laboratory conditions.Therefore the suitable width of door for the DCT2024 & DCT2024BC overhead door closer fixedin the above fixing position is 948mm.Specification Cover Packs Finishes Suitable Environments Specification Cover Packs Finishes Suitable EnvironmentsClosing Force EN Size 3Efficiency 70%Max Door Width 950mmMax Weight 60KgAngle of Opening Max 180°Suitable for LH/RH UseEasi Fix Template SuppliedAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableBSSEBPPNPPVDSNPSSSSVDCF2003BSS/FCPDCF2003EBP/FCPDCF2003PNP/FCPDCF2003PVD/FCPDCF2003SNP/FCPDCF2003SSS/FCPDCF2003SV/FCPBSSEBPPNPPVDSNPSSSSVClosing Force EN Size 2-4Efficiency 60%Max Door Width 1100mmMax Weight 80KgAngle of Opening Max 180°Suitable for LH/RH UseEasi Fix Template SuppliedAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableOptional Backcheck DCT2024BCDCT2024SVBSS DCT2024BSS/FCPEBP DCT2024EBP/FCPPNP DCT2024PNP/FCPPVD DCT2024PVD/FCPSNP DCT2024SNP/FCPSSS DCT2024SSS/FCPSV DCT2024SV/FCPDCT2024BC/SV & PB*BSS DCT2024BC/BSS/FCPEBP DCT2024BC/EBP/FCPPNP DCT2024BC/PNP/FCPPVD DCT2024BC/PVD/FCPSNP DCT2024BC/SNP/FCPSSS DCT2024BC/SSS/FCPSV DCT2024BC/SV/FCPBSSEBPPNPPVDSNPSSSSV6 7*Backcheck not covered by CE or Certifire.


MECHANICALMECHANICALDCS2024BCOverhead Door Closer Variable Power Size 2-4DCS2025BCOverhead Door Closer Variable Power Size 2-51121-CPD-AD01981121-CPD-AD01981121-CPD-AD01991121-CPD-AD0199BS EN 1154:1996 - Fig 1 FittingBS EN 1154:1996 - Fig 6 FittingBS EN 1154:1996 - Fig 1 FittingBS EN 1154:1996 - Fig 6 Fitting4 8 4 1 1 324 8421 1 34 8 5 1 1 324 8421 1 3APPROVED PRODUCTCF646APPROVED PRODUCTCF646BS EN 1154BS EN 1154FD30/60/120FD30/60/120yrGUARANTEEyrGUARANTEEThe Home of Quality <strong>Architectural</strong> Ironmongery3978Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)3978Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)2366039Torque (Nm)50403020Efficiency %: 70Max Opening 0°- 4° (Nm): 29.26Max Opening 0°- 60° (Nm): 29.63Max Closing 4° - 0° (Nm): 20.58Max Closing 92° - 88° (Nm): 11.642366039Torque (Nm)50403020Efficiency %: 67Max Opening 0°- 4° (Nm): 29.16Max Opening 0°- 30° (Nm): 29.16Max Closing 30° - 60° (Nm): 20.15Max Closing 4° - 0° (Nm): 19.4210100 30 6090120 150Door Angle (°)1800 30 6090120 150Door Angle (°)180The DCS2024BC overhead door closer has an opening force (0-30°) less than 30N whenfitted to a minimum width door of 926mm, and has an opening force (30-60°) less than 22.5Nwhen fitted to a minimum width door of 838mm tested in laboratory conditions. Thereforethe suitable width of door for the DCS2024BC overhead door closer fixed in the above fixingposition is 926mm.The DCS2025BC overhead door closer has an opening force (0-30°) less than 30N whenfitted to a minimum width door of 926mm, and has an opening force (30-60°) less than 22.5Nwhen fitted to a minimum width door of 838mm tested in laboratory conditions. Thereforethe suitable width of door for the DCS2025BC overhead door closer fixed in the above fixingposition is 926mm.Specification Cover Packs Finishes Suitable EnvironmentsSpecification Cover Packs Finishes Suitable EnvironmentsClosing Force EN Size 2-4Efficiency 70%Max Door Width 1100mmMax Weight 80KgAngle of Opening Max 180°Suitable for LH/RH UsePower Adjustment by SpringAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableBackcheckMeets recommendations of BS 8300 andApproved Document MBSSEBPPNPPVDSNPSSSSVDCS2024BC/BSS/FCPDCS2024BC/EBP/FCPDCS2024BC/PNP/FCPDCS2024BC/PVD/FCPDCS2024BC/SNP/FCPDCS2024BC/SSS/FCPDCS2024BC/SV/FCPBSSEBPPNPPVDSNPSSSSVClosing Force EN Size 2-5Efficiency 67%Max Door Width 1250mmMax Weight 100KgAngle of Opening Max 180°Suitable for LH/RH UsePower Adjustment by SpringAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableBackcheckOptional Delayed Action DCS2025BCDAMeets recommendations of BS 8300 andApproved Document MDCS2025BCBSS DCS2025BC/BSS/FCPEBP DCS2025BC/EBP/FCPPNP DCS2025BC/PNP/FCPPVD DCS2025BC/PVD/FCPSNP DCS2025BC/SNP/FCPSSS DCS2025BC/SSS/FCPSV DCS2025BC/SV/FCPDCS2025BCDA*BSS DCS2025BCDA/BSS/FCPEBP DCS2025BCDA/EBP/FCPPNP DCS2025BCDA/PNP/FCPPVD DCS2025BCDA/PVD/FCPSNP DCS2025BCDA/SNP/FCPSSS DCS2025BCDA/SSS/FCPSV DCS2025BCDA/SV/FCPBSSEBPPNPPVDSNPSSSSV89*Delayed Action not covered by CE or Certifire.


MECHANICALDCS2026BCOverhead Door Closer Variable Power Size 2-6ACCESSORIES1121-CPD-AD0200BS EN 1154:1996 - Fig 1 Fitting4 8 6 1 1 321121-CPD-AD0200BS EN 1154:1996 - Fig 6 Fitting3 8541 1 3APPROVED PRODUCTCF646BS EN 1154FD30/60/120yrGUARANTEEThe Home of Quality <strong>Architectural</strong> Ironmongery4580Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)2756245Torque (Nm)50403020Efficiency %: 76.9Max Opening 0°- 4° (Nm): 32.2Max Opening 0°- 30° (Nm): 32.2Max Closing 30° - 60° (Nm): 29.7Max Closing 4° - 0° (Nm): 24.8Product Finishes Product FinishesDCX2107Hold Open Arm to suit:DCS2024 & DCS2024BCDCS2025BC & DCS2025BCDADCS2026BC & DCS2026BCDASVDCX2201Door Closer Cover to suit:DCF2003SSSSV100 30 6090120 150Door Angle (°)180The DCS2026BC overhead door closer has an opening force (0-30°) less than 33N whenfitted to a minimum width door of 1030mm, and has an opening force (30-60°) less than 22.5Nwhen fitted to a minimum width door of 926mm tested in laboratory conditions. Thereforethe suitable width of door for the DCS2026BC overhead door closer fixed in the above fixingposition is 1030mm. (Power trace taken at 0 cycles).Specification Cover Packs Finishes Suitable EnvironmentsProduct Finishes Product FinishesClosing Force EN Size 2-6Efficiency 76%Max Door Width 1400mmMax Weight 120KgAngle of Opening Max 180°Suitable for LH/RH UsePower Adjustment by SpringAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableBackcheckOptional Delayed Action DCS2026BCDAMeets recommendations of BS 8300 andApproved Document MDCS2026BCBSS DCS2026BC/BSS/FCPPVD DCS2026BC/PVD/FCPSSS DCS2026BC/SSS/FCPSV DCS2026BC/SV/FCPDCS2026BCDA*BSS DCS2026BCDA/BSS/FCPPVD DCS2026BCDA/PVD/FCPSSS DCS2026BCDA/SSS/FCPSV DCS2026BCDA/SV/FCPBSSPVDSSSSVDCX2202Door Closer Cover to suit:DCS2024DCT2024 & DCT2024BCDCS2025BC & DCS2025BCDASSSSVDCX2203Door Closer Cover to suit:DCS2026BC & DCS2026BCDASV*Delayed Action not covered by CE or Certifire.10 11


MECHANICALDCC2024SMSurface Mounted Slim H.E Door Closer Power Size 2-41121 - CPD - AD503612EN 1154:1996 + A1:2002 + AC:20063 8421 1 3APPROVED PRODUCTCF5087BS EN 1154FD30/60/120FD120/240yrGUARANTEEThe Home of Quality <strong>Architectural</strong> Ironmongery32Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)2155432Torque (Nm)50403020Efficiency %: 80.1Max Opening 0°- 30° (Nm): 22.4Max Opening 30°- 60° (Nm): 12.2Max Closing 4° - 0° (Nm): 18.0100 30 6090120 150Door Angle (°)180The DCC2024SM surface mounted slim H.E door closer has an opening force (0-30°) less than30N when fitted to a minimum width door of 747mm, and has an opening force (30-60°) lessthan 22.5N when fitted to a minimum width door of 542mm tested in laboratory conditions.Therefore the suitable width of door for the DCC2024SM surface mounted slim H.E door closerfixed in the above fixing position is 747mm.Specification Cover Packs Finishes Suitable EnvironmentsClosing Force EN Size 2-4Efficiency 80%Max Door Width 1100mmMax Weight 80KgAngle of Opening Max 120°Suitable for LH/RH UsePower Adjustment by SpringAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableSlide ChannelSlimline BodyMeets recommendations of BS 8300 andApproved Document MBSSEBPPNPPVDSNPSSSDCP3000/BSSDCP3000/EBPDCP3000/PNPDCP3000/PVDDCP3000/SNPDCP3000/SSSBSSEBPPNPPVDSNPSSSSV13(SV = Cover Only)


MECHANICALMECHANICALDCC2003SMSurface Mounted Slim Door Closer Fixed Power Size 3DCC2024SM/36Surface Mounted H.E Door Closer Variable Power Size 2-41121 - CPD - AD5036EN 1154:1996 + A1:2002 + AC:2006123 8 3 1 1 31121 - CPD - AD5036EN 1154:1996 + A1:2002 + AC:20063 842121 1 3APPROVED PRODUCTCF5087APPROVED PRODUCTCF5087BS EN 1154BS EN 1154FD30/60/120FD30/60/120FD120/240FD120/240yryrGUARANTEEGUARANTEEThe Home of Quality <strong>Architectural</strong> Ironmongery36Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)36Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)2365936Torque (Nm)50403020Efficiency %: 77.9Max Opening 0°- 4° (Nm): 28.3Max Opening 0°- 60° (Nm): 28.3Max Closing 4° - 0° (Nm): 22.02365936Torque (Nm)50403020Efficiency %: 79.8Max Opening 0°- 30° (Nm): 22.6Max Opening 30°- 60° (Nm): 12.8Max Closing 4° - 0° (Nm): 18.010100 30 6090120 150Door Angle (°)1800 30 6090120 150Door Angle (°)180The DCC2003SM surface mounted H.E door closer has an opening force (0-30°) less than30N when fitted to a minimum width door of 753mm, and has an opening force (30-60°) lessthan 22.5N when fitted to a minimum width door of 569mm tested in laboratory conditions.Therefore the suitable width of door for the DCC2003SM surface mounted H.E door closer fixedin the above fixing position is 753mm. (Power trace taken at 0 cycles).The DCC2024SM/36 surface mounted H.E door closer has an opening force (0-30°) less than30N when fitted to a minimum width door of 753mm, and has an opening force (30-60°) lessthan 22.5N when fitted to a minimum width door of 569mm tested in laboratory conditions.Therefore the suitable width of door for the DCC2024SM/36 surface mounted H.E door closerfixed in the above fixing position is 753mm.Specification Cover Packs Finishes Suitable EnvironmentsSpecification Cover Packs Finishes Suitable EnvironmentsClosing Force EN Size 3Efficiency 77%Max Door Width 950mmMax Weight 60KgAngle of Opening Max 120°Suitable for LH/RH UseAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableSlide ChannelSlimline BodyMeets recommendations of BS 8300 andApproved Document MBSSEBPPNPPVDSNPSSSSVDCP3202/BSSDCP3202/EBPDCP3202/PNPDCP3202/PVDDCP3202/SNPDCP3202/SSSDCP3202/SVBSSEBPPNPPVDSNPSSSSVClosing Force EN Size 2-4Efficiency 79%Max Door Width 1100mmMax Weight 80KgAngle of Opening Max 120°Suitable for LH/RH UsePower Adjustment by SpringAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableSlide ChannelMeets recommendations of BS 8300 andApproved Document MBSSEBPPNPPVDSNPSSSSVDCP3202/36/BSSDCP3202/36/EBPDCP3202/36/PNPDCP3202/36/PVDDCP3202/36/SNPDCP3202/36/SSSDCP3202/36/SVBSSEBPPNPPVDSNPSSSSV14 15


MECHANICALMECHANICALDCC2024CFConcealed Slim Door Closer Variable Power Size 2-4DCC2003CFConcealed Slim Door Closer Fixed Power Size 31121 - CPD - AD5036121121 - CPD - AD503612EN 1154:1996 + A1:2002 + AC:20063 8421 1 3EN 1154:1996 + A1:2002 + AC:20063 8 3 1 1 3APPROVED PRODUCTCF5087APPROVED PRODUCTCF5087BS EN 1154BS EN 1154FD30/60/120FD30/60/120FD120/240FD120/240yryrGUARANTEEGUARANTEE2853230536The Home of Quality <strong>Architectural</strong> IronmongeryMax Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)21554Torque (Nm)50403020Efficiency %: 79.8Max Opening 0°- 30° (Nm): 22.8Max Opening 30°- 60° (Nm): 13.5Max Closing 4° - 0° (Nm): 18.223563Torque (Nm)50403020Efficiency %: 70.9Max Opening 0°- 4° (Nm): 33.4Max Opening 0°- 60° (Nm): 33.4Max Closing 4° - 0° (Nm): 23.710100 30 6090120 150Door Angle (°)1800 30 6090120 150Door Angle (°)180The DCC2024CF concealed door closer has an opening force (0-30°) less than 30N whenfitted to a minimum width door of 760mm, and has an opening force (30-60°) less than 22.5Nwhen fitted to a minimum width door of 600mm tested in laboratory conditions. Thereforethe suitable width of door for the DCC2024CF concealed door closer fixed in the above fixingposition is 760mm.The DCC2003CF surface mounted H.E door closer has an opening force (0-30°) less than33N when fitted to a minimum width door of 797mm, and has an opening force (30-60°) lessthan 22.5N when fitted to a minimum width door of 600mm tested in laboratory conditions.Therefore the suitable width of door for the DCC2003CF surface mounted H.E door closer fixedin the above fixing position is 797mm. (Power trace taken at 0 cycles).Specification Accessories Finishes Suitable EnvironmentsSpecification Accessories Finishes Suitable EnvironmentsClosing Force EN Size 2-4Efficiency 79%Max Door Width 1100mmMax Weight 80KgAngle of Opening Max 120°Suitable for LH/RH UsePower Adjustment by SpringAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableSlide ChannelSlimline BodyMeets recommendations of BS 8300 andApproved Document MArm OnlyEBP DCX2002/EBPPNP DCX2002/PNPSNP DCX2002/SNPIntumescent PackINT2024EBPPNPSNPClosing Force EN Size 3Efficiency 70%Max Door Width 950mmMax Weight 60KgAngle of Opening Max 120°Suitable for LH/RH UseAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableSlide ChannelSlimline BodyMeets recommendations of BS 8300 andApproved Document MArm OnlyEBP DCX2002/EBPPNP DCX2002/PNPSNP DCX2002/SNPIntumescent PackINT2024/36EBPPNPSNP16 17


MECHANICALDCC2024CF/36Concealed H.E Door Closer Variable Power Size 2-4ACCESSORIES1121 - CPD - AD503612EN 1154:1996 + A1:2002 + AC:20063 8421 1 3APPROVED PRODUCTCF5087BS EN 1154FD30/60/120FD120/240yrGUARANTEE30536Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)The Home of Quality <strong>Architectural</strong> Ironmongery23659Torque (Nm)50403020Efficiency %: 77.8Max Opening 0°- 30° (Nm): 23.9Max Opening 30°- 60° (Nm): 13.5Max Closing 4° - 0° (Nm): 18.6Product Finishes Product FinishesDCX2002Plated Arm to suit:DCC2024SM & DCC2024SM36EBPPNPDCX2003Chanel Forend to suit:DCC2024SM & DCC2024SM36BSSPVDDCC2003SMDCC2003SMDCC2024CF & DCC2024CF36SNPDCC2024CF & DCC2024CF36SSS100 30 6090120 150Door Angle (°)180The DCC2024CF/36 concealed door closer has an opening force (0-30°) less than 30N whenfitted to a minimum width door of 797mm, and has an opening force (30-60°) less than 22.5Nwhen fitted to a minimum width door of 600mm tested in laboratory conditions. Thereforethe suitable width of door for the DCC2024CF/36 concealed door closer fixed in the abovefixing position is 797mm.Specification Accessories Finishes Suitable EnvironmentsProduct Finishes Product FinishesClosing Force EN Size 2-4Efficiency 77%Max Door Width 1100mmMax Weight 80KgAngle of Opening Max 120°Suitable for LH/RH UsePower Adjustment by SpringAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableSlide ChannelMeets recommendations of BS 8300 andApproved Document MArm OnlyEBP DCX2002/EBPPNP DCX2002/PNPSNP DCX2002/SNPIntumescent PackINT2024/36EBPPNPSNPDCX3202/36Door Closer Cover to suit:DCC2024SM/36DCC2003SM/36EBPPNPSNPSVDCX3202Door Closer Cover to suit:DCC2024SMEBPPNPSNPSV18 19


MECHANICALMECHANICALMECHANICALMECHANICALDCFS150/EN3 & DCFS250/EN4Double Action Floor Spring 105kg & 150kgDCTS100/EN3 & DCTS150/EN4Concealed NHO Transom Closer Power Size 3& Power Size 4 with Side Load Accessories130325108Dust Cap293389140308The Home of Quality <strong>Architectural</strong> IronmongeryDCFS150/EN3 105Kg DA Floor Spring Accessories FinishesSuitable EnvironmentsDCTS100/EN3 Accessories FinishesSuitable EnvironmentsClosing Force EN Size 3Max Door Width 950mmMax Weight 105KgAngle of Opening Max 120°Suitable for LH/RH UseAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeIntumescent Pack INT2500Available1121 - CPD - AD5037EN 1154:1996 + A1:2002 + AC:20063 8 3 1 1 3yrGUARANTEEFD60BS EN 1154Left Hand Accessory PacksBSS DCXF105L/BSSPVD DCXF105L/PVDSSS DCXF105L/SSSRight Hand Accessory PacksBSS DCXF106R/BSSPVD DCXF106R/PVDSSS DCXF106R/SSSCover PlatesBSS DCXF107BSSPVD DCXF107PVDInterchangable Spindles5mm DCXF108A10mm DCXF108B15mm DCXF108C20mm DCXF108D25mm DCXF108E30mm DCXF108FBSSPVDSSSClosing Force EN Size 3Efficiency 63%Max Door Width 950mmMax Weight 105KgAngle of Opening Max 130°Suitable for LH/RH UseAdjustable Closing SpeedAdjustable Latching Speed2 Year Mechanical GuaranteeHO90 Mechanism Only Version Available DCTS100/EN3/HOyrGUARANTEESide Load Accessory PackDCXT100/SLSVDCFS250/EN4 150Kg DA Floor Spring Accessories Finishes Suitable EnvironmentsDCTS150/EN4 Accessories FinishesSuitable EnvironmentsClosing Force EN Size 4Max Door Width 1100mmMax Weight 150KgAngle of Opening Max 120°Suitable for LH/RH UseAdjustable Closing SpeedAdjustable Latching Speed10 Year Mechanical GuaranteeAccessory Packs AvailableyrGUARANTEELeft Hand Accessory PacksBSS DCXF105L/BSSPVD DCXF105L/PVDSSS DCXF105L/SSSRight Hand Accessory PacksBSS DCXF106R/BSSPVD DCXF106R/PVDSSS DCXF106R/SSSCover PlatesBSS DCXF107BSSPVD DCXF107PVDInterchangable Spindles5mm DCXF108A10mm DCXF108B15mm DCXF108C20mm DCXF108D25mm DCXF108E30mm DCXF108FBSSPVDSSSClosing Force EN Size 4Efficiency 63%Max Door Width 1100mmMax Weight 150KgAngle of Opening Max 130°Suitable for LH/RH UseAdjustable Closing SpeedAdjustable Latching Speed2 Year Mechanical GuaranteeGUARANTEEHO90 Mechanism Only Version Available DCTS150/EN4/HOyrSide Load Accessory PackDCXT100/SLSV20 21


MECHANICALMECHANICAL51308 11030 65141102025321242H2N1900 & H2N1950Thrust Bearing Pivot Set & Emergency Release Door StopBS EN 1155:1997 Explained...8050.859 74 402530.2BS EN 1155:1997 is the European standard for controlled door closing devices and, as such, tests mechanical door closer performance.Adopted by EU member states, it became a mandatory requirement for CE marking in 2004. It prescribes the test methodology and subsequent classificationof randomly selected production line products. The test data, together with supporting technical evaluation, results in a classification code.This coding allows comparison across a range of closers according to their compliance with the standard.Electrically powered hold open devices for fire doors are covered by a Constructive Products <strong>Direct</strong>ive mandate. Compliance with BS EN 1155:1997, supportedby suitable evidence, therefore allows the application of the CE mark. All conforming door closers consequently will be marked with their BS EN 1155:1997coding and details of the notified certification body.Door controls with electrical components, such as electromagnetic hold open devices, must also satisfy the requirements of both BS EN 1154:1996 and thesupplementary standard, BS EN 1155:1997 for electrically controlled door operators.25545 525Door Size/MassFive door mass grades and related hold-open power sizes are identifiedaccording to Table 1 of this European standard. Where an electricallypowered hold-open device is suitable for a range of door closers powersizes, both the minimum and maximum power sizes should be shown.H2N1900 Thrust Bearing Pivot SetRadius Version Available H2N1900/RMax Weight 80Kg (Frame/Wall Mounted)Max Weight 120Kg (Floor Mounted)Stainless Steel ConstructionPhospher Bronze Thrust Bearing10 Year Mechanical GuaranteeSuitable for use in hospital/disabled toiletsyrGUARANTEEFinishesSSSSuitable EnvironmentsCategory of UseOnly one category of use is identified for electrically poweredhold-open devices. Grade 3 - For doors for use by the public, andothers with little incentive to take care. i.e. where there is somechance of misuse of the door. Note: For electrically poweredhold-open and free-swing door closers, where the openingangle is limited by the device, provision of a separate door stopshould be used.Table 1Closer SizeMax Door Size3 950mm - 60Kg4 1100mm - 80Kg5 1250mm - 100Kg6 1400mm - 120Kg7 1600mm - 160Kg4 8 4 1 1 3Corrosion ResistanceA salt spray test to ascertaincorrosion resistance therebyestablishing suitability for use invarying environmental conditions.Five grades are identified from 0(no identified resistance) to 4 (veryhigh resistance). All Carlisle Brassclosers achieve at least Grade 3 andare suitable for use in wet, pollutedenvironments and most exteriorapplications.H2N1950 Emergency Release Door StopFinishesSuitable EnvironmentsTest CyclesTwo test durations are identified for devices manufactured to this Europeanstandard. Grade 5 - 50,000 test cycles. For all electrically powered hold-opendevices. Grade 8 - 500,000 test cycles. For all electrically powered hold-openand free-swing door closers and devices that contain operating arms.SafetyElectrically powered hold-open devices are required tosatisfy the Essential Requirement of safety in use. Thereforeonly grade 1 is identified.Secure (Pin-Lok) ReleaseStainless Steel Construction10 Year Mechanical GuaranteeSuitable for use in hospital/disabled toiletsyrGUARANTEESSSFire ResistanceOnly one grade of fire resistance is identified for electricallypowered hold-open devices manufactured to this Europeanstandard: Grade 1 - Suitable for use on fire/smoke doorassemblies subject to satisfactory assessment of thecontribution of the electrically powered hold-open deviceto the fire resistance of specified fire/smoke doorassemblies.22 23


MECHANICALMECHANICALDCCEM3024Electromagnetic HO/FS Door Closer Variable Power Size 2-4DCEM2003Electromagnetic HO/FS Door Closer Fixed Power Size 31121 - CPD - AD0191EN 1154:1996 + A1:2002 + AC:2006083 8 4 1 1 321121 - CPD - AE5001EN 1154:1996 + A1:2002 + AC:2006123 8 3 1 1 3EN 1155:1997 + A1:2002 + AC:2006 3 8 1 1 33BS EN 1155EN 1155:1997 + A1:2002 + AC:2006 3 84131 3BS EN 1155BS EN 1154BS EN 1154FD30/60/120FD30/60/120ELE CTR ICALELE CTR ICALyryrGUARANTEEGUARANTEEyrGUARANTEEyrGUARANTEE228275The Home of Quality <strong>Architectural</strong> Ironmongery38Max Closing Moment (EN)Opening MomentClosing MomentMin Closing Moment (EN)4760785138Torque (Nm)50403020Efficiency 0° - 4°%: 78Max Opening 0°- 4° (Nm): 23.42Max Opening 0°- 30° (Nm): 23.42Max Opening 30° - 60° (Nm): 12.90Max Closing 4° - 0° (Nm): 18.16224100 30 6090120 150Door Angle (°)180The DCCEM3024 surface mounted H.E door closer has an opening force (0-30°) less than30N when fitted to a minimum width door of 781mm, and has an opening force (30-60°) lessthan 22.5N when fitted to a minimum width door of 573mm tested in laboratory conditions.Therefore the suitable width of door for the DCCEM3024 surface mounted H.E door closerfixed in the above fixing position is 781mm.Specification Finishes Suitable Environments Specification FinishesSuitable EnvironmentsClosing Force EN Size 2-4Efficiency 78%Max Door Width 1100mmMax Weight 80KgAngle of Opening Max 120°Suitable for LH/RH UsePower Adjustment by SpringAdjustable Closing SpeedAdjustable Latching Speed2 Year Electrical Guarantee10 Year Mechanical GuaranteeSlide ChannelMeets recommendations of BS 8300 and Approved Document MBSSSSSVClosing Force EN Size 3Max Door Width 950mmMax Weight 60KgAngle of Opening Max 170°Suitable for LH/RH UseHold Open Swing Free Arm IncludedAdjustable Closing SpeedAdjustable Latching Speed2 Year Electrical Guarantee10 Year Mechanical GuaranteeMeets recommendations of BS 8300 and Approved Document MEBPCSSSV24 25


MECHANICALDCEM2004Electromagnetic HO/FS Door Closer Fixed Power Size 4ELECTROMAGNETIC ACCESSORIES1122 - CPD - AE5001EN 1154:1996 + A1:2002 + AC:2006123 8 4 1 1 3EN 1155:1997 + A1:2002 + AC:2006 3 8 1 1 34BS EN 1155BS EN 1154FD30/60/120ELE CTR ICALyrGUARANTEEyrGUARANTEE275The Home of Quality <strong>Architectural</strong> Ironmongery476078224Product Finishes Product FinishesDEFB100Floor Mounting BracketSVDEM100FFlush Mounted Wall MagnetSSSVSpecificationFinishesSuitable EnvironmentsProduct Finishes Product FinishesClosing Force EN Size 4Max Door Width 1100mmMax Weight 80KgAngle of Opening Max 170°Suitable for LH/RH UseHold Open Swing Free Arm IncludedAdjustable Closing SpeedEBPCSSSVDEM100SSurface Mounted Wall MagnetELE CTR ICALyrGUARANTEESSSVPSUA8/WHT1 Amp 24v DC Power Supply UnitOptional Special Order Only:3 Amp PSUA8/3/WHT5 Amp PSUA8/5/WHTWHTAdjustable Latching Speed2 Year Electrical Guarantee10 Year Mechanical GuaranteeMeets recommendations of BS 8300 and Approved Document M* see page 28 for technical details.26 27


MECHANICALMECHANICALMECHANICALTransformer Rectifiers Explained...ANCILLARY PRODUCTSAA45 Concealed Chain Spring Door Closer Finishes Suitable EnvironmentsPSUA8/WHT = 1 AmpWill power upto 6 units when using1.5mm wire or will power upto 8 unitswhen using 2.5mm wirePSUA8/3/WHT = 3 Amp*Will power upto 18 units when usingeither 1.5mm or 2.5mm wire.PSUA8/5/WHT = 5 Amp*Will power upto 44 units when using1.5mm wire or will power upto 50 unitswhen using 2.5mm wire.Suitable for LH/RH UseRadius Version Available AA45R144.5R 22.5CPPBSCRating:1A@24v dcRating:3A@24v dcRating:5A@24v dcInput Voltage: 240AC, 230ACOutput Volts: 24v dcFloating Voltage: 27.4 - 29.0Input Voltage: 240AC, 230ACOutput Volts: 24v dcFloating Voltage: 27.4 - 29.0Input Voltage: 240AC, 230ACOutput Volts: 24v dcFloating Voltage: 27.4 - 29.0503.525yr*Special Order Only*Special Order OnlyGUARANTEEFD30NOTE:50 metre max total cable length from power supply unit for above calculations.As a guideline e.g if using 100m of cable, reduce the amount of unit coverage by 50%.CDC85/R Adjustable Jamb Mounted Door Closer Finishes Suitable Environments59.4Max Door Width 940mmSCMax Weight 80Kg25.5Angle of Opening Max 110°Suitable for LH/RH Use170Transformer Rectifiers 24V DCOur range of Transformer Rectifiers are designed for our DCEM range of Electronic door closers where a smooth 24v dc supply is required. Each power supplyfeatures full monitoring of all circuitry with fault conditions displayed by means of a single yellow LED indicator.4.225The Transformer Rectifiers will also monitor mains fail and output fuse fail. The output voltage is regulated throughout the Transformer Rectifier range and allmodels are able to supply full rated output.Our Transformer Rectifiers have a relay fitted which controls the output in either energised or de energised state through two methods of switching. The relaycan be triggered by either applying 24v to coil from a remote source or through the use of a remote volt free switch connected to the “THRU LINK” terminals.The relay can be operated by any external switching source such as a fire alarm panel or other control system.yrGUARANTEEFD30/6025.5123Our Transformer Rectifiers also feature the incorporation of an additional fault relay which can be used to signal the power supply status to a remotemonitoring system, remote indicator or buzzer unit. In addition the relay can also be used to provide an input to an addressable switch monitor in order tomake the Transformer an integral part of any addressable system.CDG003 Contract Overhead Door Closer Fixed Power Size 3Closing Force EN Size 3BS EN 1154:1996 - Fig 1 FittingFinishesSVSuitable EnvironmentsAll Transformer Rectifiers we supply carry the CE mark and are fully compliant with the LVD9 Low Voltage <strong>Direct</strong>ive.Efficiency 66%Max Door Width 950mmMax Weight 60KgAngle of Opening Max 180°4 8 3 1 1 3BS EN 1154:1996 - Fig 6 Fitting4 8 3 1 1 3Suitable for LH/RH UseAdjustable Closing SpeedAdjustable Latching SpeedFully compliant with LVD9 low voltage directive.2 Year Mechanical GuaranteeCE marking.Accessory Packs AvailableSuitable for all options of fire alarm systems.In-built relay.“THRU LINK” terminals to suit older fire alarm systems.yrGUARANTEEFD30/60BS EN 115428 29


Troubleshooting and MaintenanceFitting Applications1. Check that all instructions provided by the manufacturer are adhered to and that the door closer closes the door correctly.2. Ensure that all fixing screws, including the connection of arm to body are tight.3. Check the spring strength is set correctly and adjust if necessary.Our comprehensive range of Enduro and Enduromax door closers all come with detailed fitting instructions and technical information.The three common ways to fit surface mounted overhead closers are as follows. The full range of fitting instructions in PDF format can be obtained fromwww.carlislebrass.com4. Perform checks on any controls relating to delay, closing speed, latching action and back check, and adjust as required.5. Lightly lubricate arm joints and rollers with light oil or grease.6. Ensure that at all times, care and maintenance are carried out by competent personnel and that records are kept.7. Use chart below as a guide to checking your doorset.Figure 1 (Fig 1) Straight Arm ; Standard ApplicationThe closer is mounted on the pull side of the door with the arm fixed tothe frame on the hinge knuckle side of the door.Door closer cannotclose easilyDoor Application: Offices, stores, toilets etc, where doors open into areaswhich are usually small.For o/hd closersdisconnect armsDoes closer mechanismoperate freely?NOAdjust or replace doorcloserYESDoes the door movefreely?YESNOAre the hinges plumb?YESAre the hinges stiff?NOYESAdjust or ease hingesLubricate hingesFigure 66 (Fig 66) (Fig 6) Parallel Arm ApplicationThe closer is mounted on the push side of the door and the arm is fixedto the Figure 66 bracket, parallel to the door on the opposite side of thedoor to the hinge knuckle.Door Applications: Doors opening outwards to exterior, where aestheticsor space mean Figure 1 cannot be used.Re-connect closer armsNOIs the door scraping thefloor?YESRe-hand door or planebottom railNOIs latch resistance toostrong?YESAdjust strike plate andlubricate latchNOIs the door catching theframe?YESEase door and/or frameFigure 61 (Fig 61) Transom Mounted ApplicationIs the closer correctlyinstalled?Is the closer the right sizefor the door?NONORe-position closer accordingto template/instructionsReplace closer or adjustspring strength wherepossibleThe closer is mounted on the push side of the frame over the door andthe arm is fixed to the door on the opposite side to the hinge knuckle.Door Applications: Doors where there is insufficient material in the toprail to allow the closer to be fitted on glazed doors with unsufficient fixingfor closer body.Door closer closes thedoor easily30 31


32IndexAA45 29292914,1713,15,16,182425266202089107212119191111111119202020212727222227CDC85SC/RCDG003DCC2003DCC2024DCCEM3024DCEM2003DCEM2004DCF2003DCFS150DCFS250DCS2024DCS2025DCS2026DCT2024DCTS100DCTS150DCX2002DCX2003DCX2107DCX2201DCX2202DCX2203DCX3202DCXF105DCXF107DCXF108DCXT100DEFB100DEM100H2N1900H2N1950PSUA8


Notes


Carlisle BrassParkhouse RoadCarlisleCA3 0JUEmail: sales@carlislebrass.comWeb: www.carlislebrass.comTel: 01228 511030Fax: 01228 511885

Hooray! Your file is uploaded and ready to be published.

Saved successfully!