Current- and Voltage Transmitter CVT 500Measuring input DC- and sinusoidal AC-signalsFeaturesM Arithmetic average value measurement,RMS calibrated or DCM Output 0/4 ... 20 mA or 0/2 ... 10 V DC switchselectableM Span adjustable ±5 %M Full 3-port isolationM Supply voltage 230 V ACor 24 V DCM Power on LEDM 22.5 mm case for DIN rail mountingGeneral informationTransmitter CVT 500 convert current or voltage signals to proportional industry standard signal 0/4...20 mA;0/2...10 V DC. Direct measurement of currents up to 5 A and voltages up to 400 V are possible.Short informationOutputAC / DCThe output is switch selectable on the front panel between 0/4...20m A or 0/2...10 V. For currentoutput a link from terminal 8 to 9 must be connected.The input signal can be changed from AC to DC by DIP-switch on the front panel.- 1 -

Current- and Voltage Transmitter CVT 5<strong>00</strong>Measuring input DC- and sinusoidal AC-signalsFeaturesM Arithmetic average value measurement,RMS calibrated or DCM Output 0/4 ... 20 mA or 0/2 ... 10 V DC switchselectableM Span adjustable ±5 %M Full 3-port isolationM Supply voltage 230 V ACor 24 V DCM Power on LEDM 22.5 mm case for DIN rail mountingGeneral informationTransmitter CVT 5<strong>00</strong> convert current or voltage signals to proportional industry standard signal 0/4...20 mA;0/2...10 V DC. Direct measurement of currents up to 5 A and voltages up to 4<strong>00</strong> V are possible.Short informationOutputAC / DCThe output is switch selectable on the front panel between 0/4...20m A or 0/2...10 V. For currentoutput a link from terminal 8 to 9 must be connected.The input signal can be changed from AC to DC by DIP-switch on the front panel.- 1 -


Technical dataPower supplySupply voltage : 230 V AC ±10 % or 24 V DC ±15 %Frequency AC: 47 ... 63 HzPower consumption :


Connection diagramStandard measuring rangeCustom measuring rangCurrent inputsCurrentVoltage inputsCaution!It is not permissible to usecurrent and voltage inputat the same time.VoltageVoltage output 0/2 ... 10 Vor current output 0/4 ... 20 mALink for current outputPower-on LEDDimensionsSupply voltageOutput configurationInput AC/DCCaution!Mounting of multiple unitswithout distance is onlypermitted in horizontalorientation.TS35 DIN rail mountingacc. to DIN 46277 and DIN EN 5<strong>00</strong>22- 3 -


Ordering code<strong>CVT5<strong>00</strong></strong> -1.-2.-3.1. Current measuring ranges0 not installed (custom measuring range voltage)1/5 standard type 0...1A and 0 ... 5A AC/DCSpecial measuring ranges please state in clear text2. Voltage measuring ranges0 not installed (custom measuring range current)125/250 standard type 0...125V and 0 ... 250V AC/DCSpecial measuring ranges please state in clear text3. Supply voltage0 230 V AC ±10 %5 24 V DC ±15%Note: For special measurements the end value must be in range 0.<strong>00</strong>1 ... 5A or 0.1 ... 4<strong>00</strong>V AC/DCExample of order:<strong>CVT5<strong>00</strong></strong> with voltage measuring range 0 ... 150mV and supply voltage 230V AC:<strong>CVT5<strong>00</strong></strong> - 0 - 0.15 - 0For measurement of higher currents or voltages choose current or voltage transformer.09/05-<strong>00</strong>- 4 -