12.07.2015 Views

VR101S Voltage Event Recorder System

VR101S Voltage Event Recorder System

VR101S Voltage Event Recorder System

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>VR101S</strong> <strong>Voltage</strong> <strong>Event</strong> <strong>Recorder</strong> <strong>System</strong>Set up, plug in, download, and analyzeHomes, offices, hospitals, and factoriesdepend on electronic devices. Andelectronic devices depend on goodpower quality. The Fluke <strong>VR101S</strong> is theperfect system for catching sags, swells,transients, outages and frequencyvariations on line voltage at receptacles,where the most sensitive loads areconnected.The <strong>VR101S</strong> is a starter systemthat includes a compact VR101 eventrecorder, an optical interface cable, and<strong>Event</strong>View software that turns your PCinto a power quality reporting tool.Additional VR101 event recorders canbe purchased individually, so you canmonitor several voltage conditions atmultiple locations at once.To set up a VR101 event recorder,just enter the event capture limitparameters on your PC and load theminto the recorder. <strong>Event</strong>View softwareand the optical interface cable make iteasy. Then plug the recorder into theoutlet you need to test, and leave it—there’s no need to leave a computerhooked up. The compact recorder storesany voltage event that goes outside yourlimits. The VR101 recorder can storeup to as many as 4000 events and aflashing LED tells you when eventshave been captured. The recorder alsochecks for proper hot and neutral wiringfor any grounded outlet.To get data out of the recorder, hookit back up to your computer. <strong>Event</strong>Viewsoftware can download a completehistory of the events that occurredwhile the recorder was plugged intothe receptacle. The software lets youbuild a detailed report of sags, swells,transients, outages and frequencyvariations with time-stamps anddurations.Your PC communicates to the VR101through an optical interface cable. Thismeans the PC and VR101 are insulatedfrom each other for safety. The eventrecorder is self-powered by a 7-yearlithium battery, so it is not affected bypower outages. Each VR101 <strong>Recorder</strong>has its own real-time clock for timestampingvoltage events and isidentified by a unique factory-assignedcode. With their clocks and ID codes,multiple recorders can be placedthroughout a facility to give a completepicture of power quality.


SpecificationsMemory size: 4000 eventsBattery type: 3.5V lithium (non-replaceable)Battery life: 7 yearsElectrical (voltage versions, plug style, and manual languages are determined by country)<strong>Voltage</strong> Version Operating Range Nominal Frequencies Power Consumption120V Version 70V to 140V 50 Hz or 60 Hz 2W230V Version* 140V to 270V 50 Hz or 60 Hz 3W*Not intended for use on U.S. 240V power systems.Sags, Swells and Outage Measurements<strong>Voltage</strong> Version Range Accuracy Resolution120V Version230V VersionTransient MeasurementsHot-to-neutral 0 to 200V rms ±2V rms 1V rmsNeutral-to-ground 3 to 200V rms ±2V rms 1V rmsHot-to-neutral 0 to 400V rms ±4V rms 2V rmsNeutral-to-ground 3 to 120V rms ±2V rms 1V rmsRange Accuracy ResolutionHot-to-neutral 100 to 2500V peak ±(10% reading +10V) 10VNeutral-to-ground 50 to 2500V peak ±(10% reading +10V) 10V20° to 180°Phase angle200° to 360°Minimum pulse width: 1 µsFrequency MeasurementsRange Accuracy Resolution45 to 65 Hz ±0.1 Hz (3 cycles min) 0.1 Hz±1° 1°Time Measurements: <strong>Event</strong>s < 1 secondAccuracyResolutionHot-to-neutral ±0.5 cycles 0.5 cyclesNeutral-to-ground ± 1 cycle 1 cycle<strong>Event</strong>s ≥1 second (time stamp)AccuracyResolution± (2 sec/day + 8 sec) 8 secMechanicalPhysical size: 3.35 in x 2.65 in x 1.35 in(85 mm x 68 mm x 35 mm)Weight: 4 oz (120g)EnvironmentalOperating temperature:-40 to 160°F (-40 to 70°C)Relative Humidity:0 to 95% (non-condensing)Safety: CSA listed, CSA-NRTL (to UL 3111)listed, Complies with requirements ofEN61010-1:1993. CAT III 300VComputer Hardware RequirementsIBM PC or 100% compatible,with Windows ® 3.1 or Windows 95installed and operatingAt least one free RS-232 serial portA pointing device (recommended)2 MB hard drive space4 MB RAM (8 MB for Windows 95)Accessories andOrdering InformationIncluded Accessories<strong>VR101S</strong>VR101 <strong>Voltage</strong> <strong>Event</strong> <strong>Recorder</strong>,Optical interface cable, 9-to-25 pin adapter,<strong>Event</strong>View Software on two 3 1 /2 inchfloppies, Users ManualVR101VR101 <strong>Voltage</strong> <strong>Event</strong> <strong>Recorder</strong>,Instruction SheetOrdering Information(Note: At least one <strong>VR101S</strong> is requiredfor proper operation.)<strong>VR101S</strong> <strong>Voltage</strong> <strong>Event</strong> <strong>Recorder</strong> <strong>System</strong>VR101 <strong>Voltage</strong> <strong>Event</strong> <strong>Recorder</strong> for 120Need Technical Assistance? Call:1-800-44-FLUKEToll-free in the U.S.(800) 36-FLUKE in Canada(425) 356-5500 other countriesFor more information to be sentto you by fax, call 1-800-FLUKE-FAXin the U.S. and Canada. Or, visit ourWebsite at http://www.fluke.comFluke. Keeping your worldup and running.1265619 CO165UEN 3/99 Rev D

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!