Ballast Lampholder BCPL - Relco Group

Ballast Lampholder BCPL - Relco Group Ballast Lampholder BCPL - Relco Group

relcogroup.de
from relcogroup.de More from this publisher
12.07.2015 Views

Since 1967 Since 1919 Since 1945Relco Group Germanyelectronic_lighting_designRelco Group Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.deBallast T8 Multipower (1 or 2 lamps)Standards:Safety: EN 61347nPerformance: EN 60929nRadioInterferencies: EN 55015nHarmonics: EN61000-3-2nImmunity: EN 61547Engineering drawing 1Connection diagramDrives these lampsDrives these lampsHigh efficiency electronic ballast for T8 fluorescent tubular lamps.Self adapting to tubes with different power.Pre-heating of the cathodes, suitable for frequent lighting.Covers EMC requirements. Very low harmonics.No flickering.Compact plastic housing.Max length lamp cables cm 200.BT81/MBT82/MInput voltage AC V 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60Lamp power (min./max.) W 15 - 58 2x15 - 2x58Powerfactor > 0.9c > 0.9cMax. ambient temperature Ta °C -15 .. 50 -15 .. 45Max. temperature at Tc-point °C 70 70Safety disconnection by failedlampyesyesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyesyesyesyesyesyesMax. cross section power line mm² 1.5 1.5Max. cross section lamp line mm² 1.5 1.5Dimensions LxWxH mm 30x357x28.5 30x357x28.5Version: 13.12.2009

Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.de<strong>Ballast</strong> T8 Multipower (1 or 2 lamps)Standards:Safety: EN 61347nPerformance: EN 60929nRadioInterferencies: EN 55015nHarmonics: EN61000-3-2nImmunity: EN 61547Engineering drawing 1Connection diagramDrives these lampsDrives these lampsHigh efficiency electronic ballast for T8 fluorescent tubular lamps.Self adapting to tubes with different power.Pre-heating of the cathodes, suitable for frequent lighting.Covers EMC requirements. Very low harmonics.No flickering.Compact plastic housing.Max length lamp cables cm 200.BT81/MBT82/MInput voltage AC V 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60Lamp power (min./max.) W 15 - 58 2x15 - 2x58Powerfactor > 0.9c > 0.9cMax. ambient temperature Ta °C -15 .. 50 -15 .. 45Max. temperature at Tc-point °C 70 70Safety disconnection by failedlampyesyesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyesyesyesyesyesyesMax. cross section power line mm² 1.5 1.5Max. cross section lamp line mm² 1.5 1.5Dimensions LxWxH mm 30x357x28.5 30x357x28.5Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.de<strong>Ballast</strong> for 2 Lamps BCFE2xStandards: Safety: EN 60928Radio Interferencies: 55015Harmonics: EN 61000-3-2Immunity: EN 61547Engineering drawingConnection diagramDrives these lampsDrives these lampsHigh efficiency electronic ballast for compact and tubularfluorescent lamps.Cathodes pre-heating, suitable for frequent lighting.Covers EMC requirements.No flickering. Low harmonics.Lamp disconnection, cathodes breaking, lamp end life protection.Max length lamp cables cm 100.Drives these lampsBCFE/2x11 BCFE/2x14 BCFE/2x21 BCFE/2x26Input voltage AC V 220 - 240 220 - 240 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60 50 - 60 50 - 60Lamp power (min./max.) W 2x4 - 2x11 2x8- 2x14 2x18 - 2x21 2x18 - 2x26Powerfactor 0.6 >0.9c >0.9c >0.9cMax. ambient temperature Ta °C -10 .. 50 -10 .. 50 -10 .. 50 -10 .. 50Max. temperature at Tc-point °C 80 80 80 80Safety disconnection by failedlampyes yes yes yesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampyes yes yes yesyes yes yes yesDrives these lampsProtect against electric rectifiereffectyes yes yes yesMax. cross section power line mm² 2.5 2.5 2.5 2.5Max. cross section lamp line mm² 2.5 2.5 2.5 2.5Dimensions LxWxH mm 41x170x20 41x170x20 41x170x20 41x170x20Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.de<strong>Ballast</strong> Class II BCFEStandards: Safety: EN 60928Radio Interferences: EN 55015Harmonics: EN 61000-3-2Immunity: EN 61547Engineering drawingConnection diagramDrives these lampsDrives these lampsHigh frequency electronic ballast for fluorescent lamps.Cathodes pre-heating, suitable for frequent lighting.25% energy saving compared to conventional ballasts.No flickering.Class 2 case with terminal blocks and cable clamps.Max length lamp cables cm 100.120V AC versions available.Drives these lampsBCFE/8 BCFE/14 BCFE/21 BCFE/24Input voltage AC V 220 - 240 220 - 240 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60 50 - 60 50 - 60Lamp power (min./max.) W 4 - 8 8 - 14 18 - 21 18 - 26Powerfactor > 0.6c > 0.6c > 0.6c > 0.6cMax. ambient temperature Ta °C -10 - 50 -10 - 50 -10 - 50 -10 - 50Max. temperature at Tc-point °C 88 88 88 88Safety disconnection by failedlampyes yes yes yesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampyes yes yes yesyes yes yes yesDrives these lampsProtect against electric rectifiereffectyes yes yes yesMax. cross section power line mm² 0.75 0.75 0.75 0.75Max. cross section lamp line mm² 0.75 0.75 0.75 0.75Dimensions LxWxH mm 34x115x19 34x115x19 34x115x19 34x115x19Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.de<strong>Ballast</strong> Slim BCFEILStandards: Safety: EN 60928Radio Interferencies: EN 55015Harmonics:EN 61000-3-2Immunity: EN 61547Engineering drawingConnection diagramDrives these lampsDrives these lampsHigh frequency electronic ballast for fluorescent lamps.Cathodes pre-heating, suitable for frequent lighting.25% energy saving compared to conventional ballasts.No flickering.Max length lamp cables cm 100.Equipped with push-in terminals.Drives these lampsBCFEIL/14 BCFEIL/21 BCFEIL/24Input voltage AC V 220 - 240 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60 50 - 60Lamp power (min./max.) W 6 - 14 16 - 21 18 - 26Powerfactor > 0.6c > 0.6c > 0.6cMax. ambient temperature Ta °C -10 .. 50 -10 .. 50 -10 .. 50Max. temperature at Tc-point °C 80 80 80Safety disconnection by failedlampyes yes yesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyes yes yesyes yes yesyes yes yesMax. cross section power line mm² 1.5 1.5 1.5Max. cross section lamp line mm² 1.5 1.5 1.5Dimensions LxWxH mm 22x144,5x22 22x144,5x22 22x144,5x22Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.de<strong>Ballast</strong> Slim T5-FH BT5HLStandards: Safety: EN 60928Radio Interferencies: EN 55015Harmonics: EN 61000-3-2Immunity: EN 61547Engineering drawingConnection diagramDrives these lampsHigh efficiency electronic ballast for compact and tubularfluorescent lamps. Cathodes pre-heating, suitable for frequentlighting.Covers EMC requirements.No flickering. Very low harmonics.Lamp disconnection, cathodes breaking, lamp end life protection.Max length lamp cables cm 100.Input voltage AC V 220 - 240Frequency Hz 50 - 60Lamp power (min./max.) W 28 - 35Powerfactor > 0.9cMax. ambient temperature Ta °C -15 .. 50Max. temperature at Tc-point °C 80Safety disconnection by failedlampyesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyesyesyesMax. cross section power line mm² 1.5Max. cross section lamp line mm² 1.5Dimensions LxWxH mm 21x280x21Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.de<strong>Ballast</strong> 40W BCFE/40Standards: Safety: EN 60928Radio Interferencies: EN 55015Harmonics: EN 61000-3-2Immunity: EN 61547Engineering drawingConnection diagramDrives these lampsHigh efficiency electronic ballast for compact and tubularfluorescent lamps.Cathodes pre-heating, suitable for frequent lighting.Covers EMC requirements. Very low harmonic.No flickering.Max length lamp cables cm 100.Input voltage AC V 220 - 240Frequency Hz 50 - 60Lamp power (min./max.) W 36 - 40Powerfactor > 0.9cMax. ambient temperature Ta °C -15 .. 50Max. temperature at Tc-point °C 80Safety disconnection by failedlampyesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyesyesyesMax. cross section power line mm² 2.5Max. cross section lamp line mm² 2.5Dimensions LxWxH mm 41x170x20Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.deStandards: Safety: EN 61347Performance: EN 60929Radio Interferencies: EN 55015Harmonics: EN 61000-3-2Immunity: EN 61547<strong>Ballast</strong> T5-FQ Multipower (1 or 2lamps)Engineering drawing 1Connection diagramDrives these lampsHigh efficiency electronic ballast for T5FQ fluorescent tubularlamps.Self adapting to tubes with different power.Pre-heating of the cathodes, suitable for frequent lighting.Covers EMC requirements. Very low harmonics.No flickering.Compact plastic housing.Max length lamp cables cm 200.BT5Q1/MBT5Q2/MInput voltage AC V 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60Lamp power (min./max.) W 24 - 54 2x24 - 2x54Powerfactor > 0.9c > 0.9cMax. ambient temperature Ta °C -15 .. 50 -15 .. 50Max. temperature at Tc-point °C 70 70Safety disconnection by failedlampyesyesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyesyesyesyesyesyesMax. cross section power line mm² 1.5 1.5Max. cross section lamp line mm² 1.5 1.5Dimensions LxWxH mm 30x357x28.5 30x357x28.5Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.deStandards: Safety: EN 61347Performance: EN 60929Radio Interferencies: EN 55015Harmonics: EN 61000-3-2Immunity: EN 61547<strong>Ballast</strong> T5-FH Multipower (1 or 2lamps)Engineering drawingConnection diagramDrives these lampsHigh efficiency electronic ballast for T5FH fluorescent tubularlamps.Self adapting to tubes with different power.Pre-heating of the cathodes, suitable for frequent lighting.Covers EMC requirements. Very low harmonics.No flickering.Compact plastic housing.Max length lamp cables cm 200.BT5H1/MBT5H2/MInput voltage AC V 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60Lamp power (min./max.) W 14 - 35 2x14 - 2x35Powerfactor > 0.9c > 0.9cMax. ambient temperature Ta °C -15 .. 50 -15 .. 50Max. temperature at Tc-point °C 70 70Safety disconnection by failedlampyesyesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyesyesyesyesyesyesMax. cross section power line mm² 1.5 1.5Max. cross section lamp line mm² 1.5 1.5Dimensions LxWxH mm 30x357x28.5 30x357x28.5Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.de<strong>Ballast</strong> Compact MultipowerStandards: Safety: EN 61347Performance: EN 60929Radio Interferencies: EN 55015Harmonics: EN 61000-3-2Immunity: EN 61547Engineering drawingConnection diagramDrives these lampsDrives these lampsHigh efficiency electronic ballast for compact fluorescent tubularand compact lamps.Self adapting to lamps with different power.High efficiency. Pre-heating of the cathodes.Covers EMC requirements. Very low harmonics.No flickering.Compact plastic housing.Max length lamp cables cm 200.BCFR1/M18BCFR1/M42Input voltage AC V 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60Lamp power (min./max.) W 13 - 18 22 - 49Powerfactor > 0.9c > 0.9cMax. ambient temperature Ta °C -15 .. 60 -15 .. 60Max. temperature at Tc-point °C 80 80Safety disconnection by failedlampyesyesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyesyesyesyesyesyesMax. cross section power line mm² 1.5 1.5Max. cross section lamp line mm² 1.5 1.5Dimensions LxWxH mm 67x103x30 67x103x30Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.deStandards:Safety: EN 61347nPerformance: EN 60929nRadioInterferencies: EN 55015nHarmonics: EN61000-3-2nImmunity: EN 61547<strong>Ballast</strong> Compact 2 LampsMultipower BCFR2/M18Engineering drawingConnection diagramDrives these lampsHigh efficiency electronic ballast for compact fluorescent tubularand compact lamps.Self adapting to lamps with different power.High efficiency. Pre-heating of the cathodes.Covers EMC requirements. Very low harmonics.No flickering.Compact plastic housing.Max length lamp cables cm 200.Input voltage AC V 220 - 240Frequency Hz 50 - 60Lamp power (min./max.) W 2x13 - 2x18Powerfactor > 0.9cMax. ambient temperature Ta °C -15 .. 60Max. temperature at Tc-point °C 80Safety disconnection by failedlampyesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyesyesyesMax. cross section power line mm² 1.5Max. cross section lamp line mm² 1.5Dimensions LxWxH mm 67x103x30Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.deStandards: Safety: EN 61347Performance: EN 60929Radio Interferencies: EN 55015Harmonics: EN 61000-3-2Immunity: EN 61547<strong>Ballast</strong> Compact 2 LampsMultipower BCFR2/M42Engineering drawingConnection diagramDrives these lampsHigh efficiency electronic ballast for compact fluorescent tubularand compact lamps.Self adapting to lamps with different power.High efficiency. Pre-heating of the cathodes.Covers EMC requirements. Very low harmonics.No flickering.Compact plastic housing.Max length lamp cables cm 200.Input voltage AC V 220 - 240Frequency Hz 50 - 60Lamp power (min./max.) W 2x18 - 2x42Powerfactor > 0.9cMax. ambient temperature Ta °C -15 .. 50Max. temperature at Tc-point °C 80Safety disconnection by failedlampyesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyesyesyesMax. cross section power line mm² 1.5Max. cross section lamp line mm² 1.5Dimensions LxWxH mm 79x123x33Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.de<strong>Ballast</strong> Compact BCFEIStandards: Safety: EN 60928Radio Interferencies: EN 55015Harmonics: EN 61000-3-2Immunity: EN 61547Engineering drawingConnection diagramDrives these lampsDrives these lampsHigh frequency electronic ballast for fluorescent lamps.Cathodes pre-heating, suitable for frequent lighting.25% energy saving compared to conventional ballasts.No flickering.Max length lamp cables cm 100.Equipped with push-in terminals.Drives these lampsBCFEI/14 BCFEI/21 BCFEI/24Input voltage AC V 220 - 240 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60 50 - 60Lamp power (min./max.) W 6 - 14 16 - 21 18 - 26Powerfactor > 0.6c > 0.6c > 0.6cMax. ambient temperature Ta °C -10 .. 50 -10 .. 50 -10 .. 50Max. temperature at Tc-point °C 80 80 80Safety disconnection by failedlampyes yes yesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyes yes yesyes yes yesyes yes yesMax. cross section power line mm² 1.5 1.5 1.5Max. cross section lamp line mm² 1.5 1.5 1.5Dimensions LxWxH mm 40x80x22 40x80x22 40x80x22Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.de<strong>Ballast</strong> Slim T5-FQ BT5QLStandards: Safety: EN 60928Radio Interferencies: EN 55015Harmonics: EN 61000-3-2Immunity: EN 61547Engineering drawingConnection diagramDrives these lampsHigh efficiency electronic ballast for tubular fluorescent lamps.Cathodes pre-heating, suitable for frequent lighting.Covers EMC requirements. Very low harmonic.No flickering.Max length lamp cables cm 100.BT5QL/39 BT5QL/49 BT5QL/54Input voltage AC V 220 - 240 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60 50 - 60Lamp power (min./max.) W 39 49 54Powerfactor > 0.9c > 0.9c > 0.9cMax. ambient temperature Ta °C -15 .. 50 -15 .. 50 -15 .. 50Max. temperature at Tc-point °C 80 80 80Safety disconnection by failedlampyes yes yesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyes yes yesyes yes yesyes yes yesMax. cross section power line mm² 1.5 1.5 1.5Max. cross section lamp line mm² 1.5 1.5 1.5Dimensions LxWxH mm 21x280x21 21x280x21 21x280x21Version: 13.12.2009


Since 1967 Since 1919 Since 1945<strong>Relco</strong> <strong>Group</strong> Germanyelectronic_lighting_design<strong>Relco</strong> <strong>Group</strong> Germany GmbHAgnes-Pockels-Straße 940721 HildenGermanyPhone +49(0)21 03/9119 5Fax +49(0)2103/9119 800info@relcogroup.de<strong>Ballast</strong> <strong>Lampholder</strong> <strong>BCPL</strong>Standards: Safety: EN 60928Radio Interferences: EN 55015Harmonics: EN 61000-3-2Immunity: EN 61547Engineering drawingDrives these lampsExample for use<strong>Lampholder</strong> with high frequency electronic ballast for fluorescentlamps.Cathodes pre-heating, suitable for frequent switching.25% energy saving compared to conventional ballast.No stroboscopic effect.Equipped with push-in terminals.With fully threaded cap, with hole with threaded entry M10x1 andtube stop.Lamp example<strong>BCPL</strong>/MA/13<strong>BCPL</strong>/MA/18Nominal input voltage AC V 220 - 240 220 - 240Frequency Hz 50 - 60 50 - 60Input voltage DC V 198 - 254 198 - 254Lamp power (min./max.) W 13 18Powerfactor > 0.5c > 0.5cMax. ambient temperature Ta °C -15 - 50 -15 - 50Max. temperature at Tc-point °C 80 80Safety disconnection by failedlampyesyesSafety disconnection by CathodebreakSafety disconnection by end lifespan lampProtect against electric rectifiereffectyesyesyesyesyesyesMax. cross section power line mm² 1.5 1.5Socket G24q-1 / GX24q-1 G24q-2 / GX24q-2Dimensions LxWxH mm 60 Ø36 60 Ø36Version: 13.12.2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!