7.18 Replacement of DHWmicroswitch.• Isolate appliance from electricitysupply.• Remove front casing as in section7.1.3.• Lower front control panel as insection 7.1.6.• Lift off microswitch retaining ’bow’spring,• Pull microswitch forward to removefrom mounting bracket anddisconnect wires.• Reassemble in reverse order.• Carry out electrical checks (seesection 5.1).7.19 Replacement of DHW heatexchanger• Turn off boiler as in section 7.1.1.• Remove front casing as in section7.1.3.• Release CH water pressure anddrain boiler as in section 7.1.2.• Lower front control panel as insection 7.1.6.• Unscrew the top two unions (1, fig.74), bottom left hand union andbacknut (2, fig. 74)Note: The connection between theDHW heat exchanger and watersection is a push fit joint.• Pull heat exchanger.forwards toremove.• Reassemble in reverse order usingnew sealing rings supplied.• Refill and repressurise the boiler(see Section 5.4).fig. 74GW 650/142