4.2.1 Installation accessoriesTable 3 lists the standard and optionalaccessories which are available forthe <strong>TURBOmax</strong> combination boilers.4.2.2 Unpack the boiler (fig. 11)Open the boiler carton and remove:a. protective cardboard sheetb. top and bottom decorative panelsc. polystyrene packagingNote: Care should be taken not toscratch the white surface of the boilercasing.Packed in the boiler carton are thefollowing:• boiler installation template• boiler hanging bracket• gas service valve• fixing screws and wallplugs• installation and user instructions• flue restrictor• domestic hot and cold waterconnections and straddle bracketTable 3: Installation AccessoriesStandard AccessoriesArt. No.1. Air/flue duct and terminal accessory 300 807Optional AccessoriesArt. No.1. Vertical air / flue duct (including terminal) 300 8002. Pitched roof adjustable roof tile(for use with vertical air/flue duct) 90763. Flat roof penetration collar(for use with vertical air/flue duct) 90564. 1 m air /flue duct extension 300 8025. 2 m air / flue duct exension 300 8036. Additional 90° elbow for air / flue duct 300 8087. Additional 45° bends (pair) for air / flue duct 300 8098. Additional air / flue duct joint clamps (pair) 300 8069. Se- duct flue kit 300 81010. Internal flue fixing kit 809811. Pre - installation connecting group(includes 300 813) 801512. Vaillant boiler replacement connection accessory 300 81313. Pipe cover accessory 809914. Plug in 24 hour central heating timeclock 300 82015. Plug in 7 day central heating timeclock 300 8214.3 Preparation of boilerlocation4.3.1 Select position of boiler.Refer to Section 3.2 'Boiler Location'for information regarding siting theboiler. In general the boiler must bepositioned such that:• there is adequate space around theboiler for service and maintenance• the boiler can be correctly flued,i.e. the flue terminal position is sitedin accordance with Section 3.4.1and the air / flue duct can beinstalled in accordance with theflue installation instructionssupplied.• all necessary pipework can beconnected, including the pressurerelief valve discharge pipe.fig. 11GW 601/014

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!