12.07.2015 Views

The GingiHue® Post The GingiHue® Post - Dental-Depot

The GingiHue® Post The GingiHue® Post - Dental-Depot

The GingiHue® Post The GingiHue® Post - Dental-Depot

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>The</strong> GingiHue ® <strong>Post</strong>For Restorations That Should Look Picture Perfect


Proven Performance And Innovative DevelopmentImplant restorations are a significant investment andyour patients have high aesthetic expectations. <strong>The</strong>gray projection through the gingiva common withthe use of titanium abutments can compromisethose expectations. <strong>The</strong> solution is the GingiHue ®<strong>Post</strong>, which unlike common titanium abutments, hasa gold-colored titanium nitride coating that providesa warm, natural color through the gingiva, apical tothe restoration.<strong>The</strong> titanium nitride (TiN) coating is created by aplasma coating process in which titanium andnitrogen ions are combined with titanium nitride,then molecularly bonded with the titanium substrateof the GingiHue <strong>Post</strong>. TiN was first used in themedical device industry in the 1980s. Throughoutthe years, biocompatibility testing has beenconducted on TiN and this testing, as well assubsequent clinical applications, have demonstratedthat titanium nitride is biocompatible and appropriatefor use in implantable medical devices that come incontact with bone, skin, tissues or blood.• GingiHue’s Gold-Colored TitaniumNitride Coating Blends NaturallyWith Soft Tissue On Porcelain-Fused-To-Metal Restorations• EP ® (Emergence Profile) DimensionsFor A More Natural AestheticEmergence Through Soft TissueGreater PatientSatisfaction!


<strong>The</strong> Steps For A Picture Perfect Restoration With A GingiHue ® <strong>Post</strong>Step 1<strong>The</strong> implant integration and tissue maturation arecomplete. <strong>The</strong> pre-prepared GingiHue <strong>Post</strong>,matching the emergence profile of the soft tissue,can now be placed.Step 2<strong>The</strong> Certain ® GingiHue <strong>Post</strong> uses a CertainGold-Tite ® Screw, torqued to 20Ncm. <strong>The</strong> externallyhexed GingiHue <strong>Post</strong> uses a Gold-Tite Screw,torqued to 32–35Ncm. <strong>The</strong> GingiHue <strong>Post</strong> isgold-colored, not gray, yielding a more natural andaesthetic result in the region between the top of theimplant and the crown margin.Step 3<strong>The</strong> Prep-Tite ® Cap is placed using temporarycement. In addition to protecting surroundingtissue, the cap also provides tissue retraction forsimplifying direct impressioning.Step 4With the healing cap removed, the abutment isprepared using similar techniques as with a naturaltooth. If substantial adjustments are required,extra-oral preparation using an abutment holder isan option. Impression-taking is also done byconventional methods. (Alternatively, an impressioncoping can be used to create a model for laboratorypreparation of the post.)Step 5A GingiHue <strong>Post</strong> under the soft tissue results in anatural pink tone to the gingiva.


<strong>The</strong> Sure Way To A Confident Smile0º Straight <strong>Post</strong>:• Gold Standard ZR (Zero Rotation)machining virtually eliminates micromovement on external hex versions formore secure abutment connection• Certain ® QuickSeat ® Connection producesan audible and tactile click confirmingproper seating on OSSEOTITE ® andNanoTite Certain Implants15 o Pre-Angled <strong>Post</strong>:• 12-point hex machining allows formultiple placement positions for idealangle correction of implants placed atcompromised anglesGingiHue ® <strong>Post</strong>s:• Titanium alloy with a titanium nitridecoating for a warm, natural hue throughthe soft tissue for improved aesthetics•EP ® (Emergence Profile) Dimensions fora more natural aesthetic emergencethrough soft tissue• Potentially eliminates need forcustom abutments• Certain QuickSeat Connectionproduces an audible and tactile clickconfirming proper seating• Collar heights of 2mm and 4mm, whichcan be cemented to a pre-preparedmargin or adjustments can be made tofollow the natural gingival contourPrep-Tite ® Caps:• Achieve tissue retraction,permitting impressioning withoutretraction cord when margin isnot modified• Provide temporary protection ofthe surrounding area before therestorative phase• Act as healing cap if surgeonplaces the abutmentGold-Tite ® Screws:• Coated with 24-carat gold• Torqued to 32-35Ncm with externalhex implants and 20Ncm with CertainInternal Connections Implants. Achieves75% greater pre-load, resulting in:1. Reduced propensity for screw loosening2. Potentially less microleakage3. Reduced incidence of screw breakageand restorative failure4. Increased confidence in cementedrestorations

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!