12.07.2015 Views

Instructions for the Fire System Designer (FSD) Rel. 2.1 - Bosch

Instructions for the Fire System Designer (FSD) Rel. 2.1 - Bosch

Instructions for the Fire System Designer (FSD) Rel. 2.1 - Bosch

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Security <strong>System</strong>sIssue/Amendment<strong>Instructions</strong> <strong>for</strong> <strong>the</strong> <strong>Fire</strong> <strong>System</strong> <strong>Designer</strong> <strong>Rel</strong>. <strong>2.1</strong> 3/6From Our Reference Datevon Rosenstiel March 31, 2009Page1 IntroductionThese instructions explain <strong>the</strong> features included with <strong>the</strong> <strong>Fire</strong> <strong>System</strong> <strong>Designer</strong> <strong>Rel</strong>ease <strong>2.1</strong>. Itprovides basic in<strong>for</strong>mation on operating <strong>the</strong> <strong>Fire</strong> <strong>System</strong> <strong>Designer</strong>. The following chapters explain<strong>the</strong> new features:– Extinguishing systems interfaces– Networking with fiber optic cable (FOC)– Opening old systems in combination with BCM-0000-BNew products:- FNM-420 LSN improved Sounders- FAS-420-TM Smoke Aspiration <strong>System</strong>- Interface modules (FLM-420-O8I2; FLM-420-RLE-S (Extinguishing Interface Module);FLM-420-O1I1)- BCM-0000-B Battery Controller ModuleNote:When you install <strong>FSD</strong> <strong>Rel</strong>ease <strong>2.1</strong>, you can retain <strong>the</strong> personalized sequence of <strong>the</strong> products in<strong>the</strong> selection bar and any saved parameters without having to uninstall <strong>the</strong> previous version.2 Interfaces <strong>for</strong> Activating Extinguishing <strong>System</strong>sExtinguishing systems can be activated from <strong>the</strong> FPA-5000 in two different ways:1. Via <strong>the</strong> FLM-420-RLE-S Extinguishing Interface Module2. Via <strong>the</strong> RMH 0002 A functional moduleIf you want to use <strong>the</strong>se products to activate an extinguishing system in <strong>the</strong> <strong>FSD</strong>, select <strong>the</strong>variant marked with a yellow warning triangle and "EA" in <strong>the</strong> CTN. In this context, "EA" stands <strong>for</strong>"Extinguishing Area" and is only attributed to <strong>the</strong> product name in <strong>the</strong> <strong>FSD</strong>Each deployment of one of <strong>the</strong>se products within an FPA-5000 constitutes an extinguishing area


Security <strong>System</strong>sIssue/Amendment<strong>Instructions</strong> <strong>for</strong> <strong>the</strong> <strong>Fire</strong> <strong>System</strong> <strong>Designer</strong> <strong>Rel</strong>. <strong>2.1</strong> 4/6From Our Reference Datevon Rosenstiel March 31, 2009PageHow does <strong>the</strong> <strong>FSD</strong> satisfy <strong>the</strong> standard <strong>for</strong> activating extinguishing systems?In <strong>the</strong> <strong>FSD</strong>, <strong>the</strong> extinguishing system and extinguishing interface module with <strong>the</strong> yellow warningtriangle are subject to legalities aimed at satisfying standards:– If a second extinguishing area is set up on a fire panel (via FLM-420-RLE-S EA orRMH 0002 A EA), <strong>the</strong> <strong>FSD</strong> requires a redundant panel (reason: if a panelcontroller fails, no more than one extinguishing area is allowed to fail)– FLM-420-RLE-S EA Extinguishing Interface Modules cannot be combined witho<strong>the</strong>r products in a loop– If a second FLM-420-RLE-S EA is placed on <strong>the</strong> same loop, <strong>the</strong> <strong>FSD</strong> requires asecond LSN module of <strong>the</strong> same type in <strong>the</strong> plausibility list– This second LSN module must not be assigned products as it <strong>for</strong>ms a loop with <strong>the</strong>LSN module on which <strong>the</strong> extinguishing interface modules are located (reason: In<strong>the</strong> event that one of <strong>the</strong> LSN modules is faulty, no more than one extinguishingarea is allowed to fail).– To avoid products unintentionally drawing on <strong>the</strong> redundant LSN module:1. Right-click <strong>the</strong> redundant LSN module2. Select "Extinguishing area redundancy".The module is <strong>the</strong>n hidden and no more products can be added– A maximum of 8 extinguishing areas may be entered on each panel.The <strong>FSD</strong> <strong>the</strong>re<strong>for</strong>e restricts <strong>the</strong> total of FLM-420-RLE-S EA and RMH 0002 A EAto 8 items altoge<strong>the</strong>r3 Networking with Fiber Optic Cable3.1 Background:– You can use an FOC/CAN converter to network a panel with ano<strong>the</strong>r panel viafiber optic cable (FOC).– If one panel in <strong>the</strong> network is networked with two o<strong>the</strong>r panels via fiber optic cable,<strong>the</strong>se panels require two FOC/CAN converters.– The FOC/CAN converters each use 100 mA.– They do not have a product ID as <strong>the</strong>y are obtained locally.3.2 Implementation in <strong>FSD</strong>This is how to define in <strong>the</strong> <strong>FSD</strong> which panels are connected with each o<strong>the</strong>r via fiber opticcables:


Security <strong>System</strong>sIssue/Amendment<strong>Instructions</strong> <strong>for</strong> <strong>the</strong> <strong>Fire</strong> <strong>System</strong> <strong>Designer</strong> <strong>Rel</strong>. <strong>2.1</strong> 5/6From Our Reference Datevon Rosenstiel March 31, 2009Page– Left-click a panel.The panel's inventory opens.– Define whe<strong>the</strong>r this panel is connected to one or two panels by selecting "IN" or"OUT".– For each checkbox you select, an FOC/CAN is added to <strong>the</strong> inventory of <strong>the</strong>relevant panel.4 Opening Old <strong>FSD</strong> FilesIf a saved <strong>FSD</strong> file containing an MPC 0000 A or BCM 0000 A (old products) is opened, a promptwill appear, asking whe<strong>the</strong>r this file should be used as an old system.4.1 What happens if <strong>the</strong> file is opened as an old system?1. The system is defined as "already installed".– In <strong>the</strong> panel's inventory (left-click on panel), all elements are marked as installed.2. The BCM 0000 A is replaced in <strong>the</strong> inventory with a BCM-0000-B, but <strong>the</strong> <strong>FSD</strong> behavesas though it were a BCM 0000 A:a. The MPC 0000 A is retained; <strong>the</strong>se would not be possible with a BCM-0000-B(incompatible).b. For <strong>the</strong> purposes of battery calculation, it uses power from <strong>the</strong> old BCM 0000 A.c. The difference of 6 mA is incorporated in <strong>the</strong> BCM-0000-B standby current.3. If <strong>the</strong> system is now extended, <strong>the</strong> current consumption and <strong>the</strong>re<strong>for</strong>e <strong>the</strong> battery capacityincrease until, eventually, ano<strong>the</strong>r battery controller module is needed.a. As <strong>the</strong> old BCM 0000 A is no longer available, <strong>the</strong> <strong>FSD</strong> adds a BCM-0000-B, whichappears in <strong>the</strong> order list.b. As <strong>the</strong> MPC 0000 A and BCM-0000-B are incompatible, <strong>the</strong> old system's MPC0000 A must now be replaced with a MPC-0000-B.c. The corresponding instruction appears in <strong>the</strong> plausibility window if a new BatteryController Module is added to <strong>the</strong> system.d. If you click <strong>the</strong> instruction, you will be taken to <strong>the</strong> "Parameter" menu item, where<strong>the</strong> MPC-0000-B can be manually selected (please also select <strong>the</strong> language).e. The instruction <strong>the</strong>n disappears from <strong>the</strong> plausibility window.4.2 What happens if <strong>the</strong> file is not opened as an old system?1. All MPC 0000 A units are replaced by <strong>the</strong> new MPC-0000-B.2. All BCM 0000 A units are replaced by <strong>the</strong> new BCM-0000-B.


Security <strong>System</strong>sIssue/Amendment<strong>Instructions</strong> <strong>for</strong> <strong>the</strong> <strong>Fire</strong> <strong>System</strong> <strong>Designer</strong> <strong>Rel</strong>. <strong>2.1</strong> 6/6From Our Reference Datevon Rosenstiel March 31, 2009Page3. In terms of battery calculation, in some cases <strong>the</strong> battery capacity may be changed as <strong>the</strong>power of <strong>the</strong> new products is fractionally different from that of <strong>the</strong> old products.4. No system elements are defined as "already installed".

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!