12.07.2015 Views

904/905 and 906/907 Titrando

904/905 and 906/907 Titrando

904/905 and 906/907 Titrando

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>904</strong>/<strong>905</strong> <strong>and</strong><strong>906</strong>/<strong>907</strong> Titr<strong>and</strong>oIntelligent potentiometric titrators –Karl Fischer titratorsSTAT titrators


02The intelligent all-roundersfor the modern titration laboratory


Reagent dosing à la carteTitrating means dosing intelligently. The Titr<strong>and</strong>o System The space-saving Dosino04gives you the choice. With the <strong>905</strong> <strong>and</strong> <strong>907</strong> Titr<strong>and</strong>o youdose with Dosinos <strong>and</strong> Dosing Units that are attacheddirectly onto the reagent bottle. With the <strong>904</strong> <strong>and</strong> <strong>906</strong>Titr<strong>and</strong>o dosing is carried out by using Exchange Units.One of these is located on the <strong>904</strong> or <strong>906</strong> Titr<strong>and</strong>o,which can control additional Dosimats with their Ex -change Units. Mixed systems with Dosing <strong>and</strong> ExchangeUnits are possible. This means that your choice doesn’tlead you down a blind alley – full flexibility is retained.The 806 Exchange Unit – a time-proven conceptwith added intelligenceSince 1973 Metrohm has produced Exchange Units withautomatic valve switching. The Exchange Unit has beencontinuously developed. The latest version is the 806Exchange Unit. It dispenses reagents with the uniqueresolution of 20’000 steps per cylinder volume.The patented Dosino with its Dosing Unit can be mounteddirectly onto the reagent bottle. This means that dosingrequires no additional bench space. Thanks to adapters,any reagent bottle can be used directly. The Dosinohouses the latest state-of-the-art electronics <strong>and</strong> micromechanics.The Dosing Unit can be exchanged withinseconds. Thanks to its transparent housing any bubblesthat may be present in the dosing cylinder can be seen<strong>and</strong> removed immediately <strong>and</strong> the valve position is al -ways shown. Rinsing <strong>and</strong> preparation of the Dosing Unitcan be carried out automatically; manual dismantling<strong>and</strong> rinsing are not necessary.


854 iConnect – green, digital <strong>and</strong> mobile06854 iConnect – Measuring input «on a chip»The Metrohm green color has always meant leadingedgetechnology. Thanks to the most advanced electronicsMetrohm has been able to reduce the measuringinput to the size of a postage stamp. This means that thecomplete measuring input fits in the electrode cablehead. It is automatically recognized <strong>and</strong> identified by itsserial number.Digital data transferDirectly in the sensor, the analog/digital converter of thelatest generation in the 854 iConnect converts the analogmeasuring signal into binary code. Digital data transmissionmeans that the measuring signal is no longersusceptible to electrostatic influences. Interference-freetransmission can now always be guaranteed, no matterhow long the electrode cable.Just take the measuring input with you!With the 854 iConnect the sensor <strong>and</strong> measuring inputare always calibrated together <strong>and</strong> the calibration data isstored in the intelligent electrode. As the measuringinput is no longer built into the instrument, the electrode<strong>and</strong> 854 iConnect can be used together with differenttitrators. The calibration procedure is no longer associatedwith a particular titrator.The iTrodes – electrodes with brainsThe iTrodes of the new intelligent electrode generationconfirm Metrohm’s long-st<strong>and</strong>ing leadership position inthe field of potentiometric titration.The electrode used for the titration is the most importantcomponent of any titration system, <strong>and</strong> until now it hasbeen just this electrode that has formed the last gap intraceability. The Titr<strong>and</strong>o with iConnect now closes thisgap <strong>and</strong> therefore guarantees complete traceability ofthe analytical result to each component participating inthe analysis.


Digital identification – no more mix-upsThe built-in memory chip allows the storage of suchimportant sensor data as article <strong>and</strong> serial numbers, calibrationdata, calibration history, working life <strong>and</strong> calibrationvalidity period.All the sensor data is read in automatically when theiTrode is connected to the Titr<strong>and</strong>o. Mix-ups or edit ingerrors are therefore eliminated.If the sensor is used with different instruments or if youwish to prevent inexperienced users from having to calibratethe electrode on their own instruments then theelectrode can be calibrated on a different instrumentunder defined conditions. The calibration data stored inthe chip makes the electrode transferable; it does notneed to be recalibrated each time that it is used with adifferent instrument.07The electrode is identified automatically. If the type ofelectrode is not the same as that defined in the methodthen the user is informed. This means that it is not possibleto use an incorrect electrode.Storage of calibration data – outliers have nochanceMonitoring functions allow the exclusion of electrodeswhose calibration data lies outside the limits or whosecalibration period has already expired.Compatible with all existing sensorsDespite its new digital measuring interface<strong>and</strong> intelligent sensors, the Titr<strong>and</strong>o withcombined analog <strong>and</strong> digital measuringinput also supports conventional sensors.This means that you can continue to useall your sensors.


The Titr<strong>and</strong>o System at a glance08Thanks to its modular concept the Titr<strong>and</strong>o System canbe optimally adapted to any application. It meets therequirements of FDA Regulation 21 CFR Part 11. Profitfrom its intelligence <strong>and</strong> multiple communicationoptions!Transparent operation – the Titr<strong>and</strong>o accelerates methoddevelopment <strong>and</strong> simplifies routine operation.More intelligence: The Data Chip of the Exchange Unit<strong>and</strong> Dosing Unit contains all important titrant data. Theintelligent sensor «iTrode» guarantees that no wrong orexpired electrode is used.The large color screen of the Touch Control informs youabout the instrument condition <strong>and</strong> offers uniquely comfortableoperator guidance, including one-touch titrationsvia «favourite» icons for operation via a PC theappear ance is exactly the same.


iConnect <strong>and</strong> iTrodes – digital data transfer <strong>and</strong> automaticelectrode recognition. The Data Chip of the intelligentsensors contains all important sensor data.NEW: The automatic GLP-compliant electrode test allowsan objective evaluation of the electrode <strong>and</strong> leaves nothingto chance. Reliable <strong>and</strong> reproducible results are thereforeguaranteed.09Numerous worked-out methods <strong>and</strong> titration examplesfacilitate familiarization. Method templates <strong>and</strong> calculationformula templates are available for developing yourown methods.Optimal reagent h<strong>and</strong>ling by either Exchange Unit orDosing Unit.More intelligence: The Data Chip of the Exchange Unit orDosing Unit contains all important titrant data.Lab Link provides access to the Intranet. Print your reporton a network printer, save your report on a network driveor remote control your Titr<strong>and</strong>o from your office computer.When combining tiamo <strong>and</strong> Titr<strong>and</strong>o, the user profitsfrom a Client-Server database.Parallel titration – with tiamo a Titr<strong>and</strong>o can workwith two titration cells at the same time.The Titr<strong>and</strong>o System can be fully automated, also includingsample preparation (weighing, homogenization,filtration, pip etting).


Uniquely intelligent – easy to operate10Favorites for quick method startMethods can be linked to a Favorite icon on the startingscreen of the 840 Touch Control. Start your titration bypressing just one button.By using our methods you can profit from our manyyears of experience in the titration field. All titrationmethods developed on Metrohm Titrinos can be convertedinto Titr<strong>and</strong>o methods automatically using a PC.As storage media for your methods, sample data <strong>and</strong>results there are the Titr<strong>and</strong>o itself, a memory card 1 or aPC with its numerous possibilities. This allows completestorage security to be achieved, with the prevention ofmethod <strong>and</strong> data loss, plus an increase in operationalsecurity.Intelligence creates transparencyOperating the Titr<strong>and</strong>o System is simple <strong>and</strong> intuitive.The operator guidance system can be regarded as exemplary.In addition, the following tools make life easier forthe Titr<strong>and</strong>o user:• The «Quick Access» function (direct parameters) allowsdirect access the parameters required for the givenapplication. These parameters can come from a widerange of different areas of the instrument program.This means that it is no longer necessary for you toclick your way through different operating levels!«Quick Access» is invaluable for routine analysis.• The «Help» fixed key shows a context-related help textin the display.• The «Follow me» help function is available when workingwith a PC. Continuous explanations about thecurr ent surroundings are given in a separate window<strong>and</strong> further possible procedures are indicated.• The st<strong>and</strong>ard user methods can be modified to suityour requirements. Method templates <strong>and</strong> calculationformula templates are available for developing yourown methods. Methods can be stored under meaningfulmethod names (32 characters) <strong>and</strong> structureddirectories can be used; this makes sorting, identification<strong>and</strong> searching much easier.• Whereas in the expert dialog all settings are available,the routine dialog can be freely configured, i.e. it canbe custom-made to meet the requirements of theparticular user. This means that users can load their«profiles» from the personal Keycard <strong>and</strong> see onlythose operating elements that they actually need.The Titr<strong>and</strong>o puts an end to puzzling out the meaning ofcoded error messages. It tells you what is going on inclear text. Not only this; it also suggests suitable measuresfor remedying any faults.1Commercial CompactFlash card; non-volatile, compact datamemory that does not need any battery.Routine Methods can be linked to a «Favorite» icon on the startingscreen of the 840 Touch Control. Titrations are started by pressingjust one button.


11The Titr<strong>and</strong>o in the modern laboratoryData management is knowledge managementData must always be available: either for direct information,for transfer to a data system, for further processingor for an audit. The data that your Titr<strong>and</strong>o System providesyou with can be printed out <strong>and</strong> stored in a conventionalmanner. However, all advanced data managementfunctions are available, for example storage on aPCMCIA card 2that is simply inserted in the TouchControl, in the PCMCIA port of the PC or an appropriatecard reader.When you work with PC Control or tiamo TM , you canuse all the storage options offered by the PC world, forexample hard drives, network drives, servers, Intranet…On request the Titr<strong>and</strong>o can produce a machine-readablePC/LIMS report. One thing is clear: As for data storage<strong>and</strong> transfer, the Titr<strong>and</strong>o is a state-of-the-art instrument.Lab LinkIf you want to connect your Titr<strong>and</strong>o System directly to asuperior data system, there is nothing in the way: The847 USB Lab Link opens up internal networks (Intranet,LIMS 3 , LAN 4 ) to the Titr<strong>and</strong>o, with all that this implies.Network printers can be used for printing out analysisreports. Or would you like to remote-control yourTitr<strong>and</strong>o? The 847 USB Lab Link provides access to yourtitrator from any PC.Never has integration into your LIMS structurebeen so easy!Unleash your printer!Laboratory bench space is scarce <strong>and</strong> expensive. Most ofthe space required by a titration system is occupied bythe printer. Its cable connection means that it has to belocated near the Titr<strong>and</strong>o. Wireless communication viaBluetooth now allows to place the printer at some distance(up to 10 meters) from the Titr<strong>and</strong>o. This freesvaluable bench space <strong>and</strong> has the additional advantageof removing the printer from the potentially hazardouseffects of splash water <strong>and</strong> chemicals.2A CompactFlash card with adapter is included in the st<strong>and</strong>ard accessories of the Touch Control. PCMCIA = Personal ComputerMemory Card International Association3LIMS = Laboratory Information Management System4LAN = Local Area Network


12Compatibility <strong>and</strong> traceabilityGLP, GMP, 21 CFR Part 11 are becoming increasinglyimportant in day-to-day laboratory life. The Titr<strong>and</strong>oSystem is entirely oriented towards quality managementin the laboratory <strong>and</strong> offers the following possibilities:• Each time that it is switched on the Titr<strong>and</strong>o Systemcarries out a self-diagnosis.• If it has been programmed accordingly then the instrumentwill remind you about any validation or servicework that is due.• You can enter limits for results; their observance will bechecked for each determination.• The titer of the titrant can be monitored as a functionof time in both tabular form or as a graph, similar to acontrol card.• The calibration history of the sensors can be called up.This means, for example, that alterations to the sensorcaused by aging can be recognized before they affectthe results.• All changes to the methods are documented; traceabilityis guaranteed.The Titr<strong>and</strong>o allows strict control of rights of access usinglogin <strong>and</strong> password. The requirements defined in FDARegulation 21 CFR Part 11 regarding «electronic signature»<strong>and</strong> «electronic record» are fulfilled in the st<strong>and</strong>alonesystem using Touch Control as well as in the versioncontrolled via PC. This also applies to the otherpoints contained in this regulation, namely the protectionof electronic records against accidental or intentionalalteration <strong>and</strong> the complete traceability. TheTitr<strong>and</strong>o with Touch Control is the only st<strong>and</strong>-alone titrationsystem with Audit Trail.Quality management at MetrohmQuality has always been extremely important forMetrohm. On 5 November 1993 our company achievedthe ISO 9001 certificate of quality. The Metrohm qualitymanagement system is continually being perfected <strong>and</strong>checked by both internal <strong>and</strong> external audits.


Integrated AutomationPerfect modularityThe possibilities for upgrading the Titr<strong>and</strong>o System arenothing short of amazing. First the bare figures: Thebasic unit consists of a Titr<strong>and</strong>o with one measuring in -ter face. This basic unit can be extended to form a supertitratorthat controls 12 burets <strong>and</strong> boasts 6 galvanicallyseparated measuring interfaces. Between these twoextremes lies the whole spectrum of Titr<strong>and</strong>o possibilities.Among them you will certainly find a Titr<strong>and</strong>oSystem that can solve your particular application problemin an optimal way. At the same time you have the certaintythat your Titr<strong>and</strong>o System will master all yourfuture applications as it is fully upgradable. As a resultyou can view the future with confidence.13Automation pays dividends!Increasing sample numbers, time-consuming samplepreparation steps <strong>and</strong> unattended overnight operationare good reasons for using sample changers. The Titr<strong>and</strong>ohas the necessary intelligence to control sample changers<strong>and</strong> offers – together with the 814 USB Sample Processor<strong>and</strong> 815 Robotic USB Sample Processor XL – a highde gree of automation at low investment costs.It’s so simpleYou connect the sample changer to the Titr<strong>and</strong>o’s USBport <strong>and</strong> the world of automation opens up to you.


Water determination with the Titr<strong>and</strong>o14Karl Fischer titration with the Titr<strong>and</strong>oThe Karl Fischer water determination is one of the mostfrequently applied laboratory methods. In contrast toother water determination methods it is specific as wellas rapid <strong>and</strong> requires no expensive equipment. With anapplication range of 0.1% to 100% water the volumetricKarl Fischer titration is used in a wide variety of fields. Nomatter whether you determine the water content infood, cosmetics or pharmaceutical products, the Titr<strong>and</strong>ois always the right instrument.In addition to the potentiometric titration modes SET,DET <strong>and</strong> MET, the <strong>906</strong>/<strong>907</strong> Titr<strong>and</strong>os come with a specialKarl Fischer mode whose sophisticated control algorithm,combined with the precision of our intelligent ExchangeUnits or Dosing Units, guarantees highly precise results.Like the other modes, the KF mode excels with easy <strong>and</strong>intuitive user guidance. Just one example: The KF iconsshow you at a glance whether the instrument is still busyconditioning or whether you can start the water determination.The electrode test <strong>and</strong> the newly created parameter«safety stop» prevent cell run-over during conditioning.If, for example, the electrode is not connected correctlyor the titration cell is very humid, conditioning is stoppedafter a given time or a given volume of KF reagentadded. This new feature increases work safety in yourlaboratory.The 803 KF Titration St<strong>and</strong>Use the 803 KF Titration St<strong>and</strong> for stirring <strong>and</strong> manuallyexchanging the spent titration vessel contents. With theintegrated membrane pump, solvent can be aspirated oradded without the cell having to be opened. This translatesinto vastly reduced conditioning times.Automatic reagent change – so very easy!An even more comfortable option is the automatic reagentchange with the Dosino. You simply trigger thechange, which is then carried out automatically by theinstrument.The iodine drop indicates the KF reagentaddition during conditioning.Conditioning is finished <strong>and</strong> the sample canbe added.


16STAT titrationThe determination of enzyme activity (lipase, trypsin,etc.) or the release kinetics of antacid tablets require atitrator that rapidly adjusts to a preset pH value <strong>and</strong>keeps it constant for a long period. The controller of theTitr<strong>and</strong>o has been optimized for this task <strong>and</strong> is one ofthe best on the market. It can also be used to determinethe kinetics of acid-base or redox reactions.T<strong>and</strong>em dosingT<strong>and</strong>em dosing is a feature that prevents dosing interruptionswhen the buret is refilled during the titration – asecond buret immediately takes over. In this way rapidreactions with a high reagent consumption can be monitored with maximum accuracy. T<strong>and</strong>em dosing is alsoavailable for simple <strong>and</strong> monitored dosing.


The Titr<strong>and</strong>o in the synthesis laboratoryIn the synthesis laboratory different problems are facedto those encountered in titration. Here a particular pHvalue must be kept constant or multiple dosing has to becarried out under exactly defined conditions. This meansthat a certain volume of a solution must be added withina fixed time. In addition to controlled dosing, the parameterspH (or potential) <strong>and</strong> temperature have to be continuouslyrecorded, thus providing complete documentationof the synthesis procedure.17Everything under controlIf a monitored parameter should infringe the set limits,the user can decide whether dosing should be continuedor interrupted <strong>and</strong> then continued manually or automatically,again observing the limits.ControllerAs an innovation the Titr<strong>and</strong>o can perform control tasks.External devices can be controlled with the aid of freelyprogrammable TTL signals or communication via RS 232.This means that it is possible to to run the external heating<strong>and</strong> cooling devices, pumps or similar equipment byremote control.Example of a neutralization process:1. DOS Addition of 150 mL reagent in 10 min with temperature monitoring2. Pause 5 min under stirring3. STAT Adjust pH = 7.5 with temperature monitoring4. SET Post reaction, for example, during 10 min; endpoint pH = 7.5


tiamo TM – titration <strong>and</strong> more!18tiamo TM is a control <strong>and</strong> database software for titrators,dosing devices <strong>and</strong> sample changers that allows completelaboratory automation. This is why the nametiamo TM st<strong>and</strong>s for «titration <strong>and</strong> more» – tiamo TM c<strong>and</strong>o much more than just titrate.Easy to useThe modern user interface makes it easy for users tofa miliarize them-selves quickly with tiamo TM . All comm<strong>and</strong>s<strong>and</strong> controls are to be found exactly where youexpect them to be. The layout manager can be used toconfigure the screen view individually for each user. Thismeans that the users see only those windows or buttonsthat are required for their work. This shortens the familiarizationperiod for routine users to a minimum.Parallel titrationBoth measuring inputs <strong>and</strong> all the Dosinos connectedto a Titr<strong>and</strong>o can be controlled independently of eachother. In combination with tiamo TMthis allows theparallel titration of two identical or two different sampleswith one single titrator.Overcomes limitsThe tiamo database provides all the important toolsfor the management, searching <strong>and</strong> grouping of results.Quick filters allow the user to search through thous<strong>and</strong>sof results in a matter of seconds <strong>and</strong> show the searchedforinformation in a clear way. Chart plots provide a rapidoverview of the chronological sequence of results. Theuser can utilize all the possibilities for re-calculation <strong>and</strong>re-evaluation.LIMS & Co.The acceptance of PC-controlled analytical systemsdepends largely on the possibility of simple <strong>and</strong> favorablypriced integration in existing laboratory information systems,central databases <strong>and</strong> long-term archiving systems.Data generated in tiamo TM is exported in CSV or XMLfor mat. This makes possible the simple connection to allthe usual LIMS products found on the market. Analysisre ports can be generated simply <strong>and</strong> flexibly with thenew report generator, which allows the free definition ofreport templates. In this way one or more determinationscan be shown at any time with a freely selectable layoutin pdf format or as a paper printout.


tiamo increases efficiencyThe graphical method editor gets more out of yourtitration system. Methods can be drawn up easily <strong>and</strong>quickly by using the numerous templates. You can program<strong>and</strong> link actions that are to be carried out at thesame time. tiamo TM is flexible <strong>and</strong> adapts itself to youranalytical sequences – not vice versa.Comfortable conformitytiamo TM also sets new st<strong>and</strong>ards with respect to complyingwith GMP, GLP <strong>and</strong> FDA requirements. tiamo TM hasbeen consistently oriented to comply with FDA Regulation21 CFR Part 11 <strong>and</strong> its customer-specific interpretations.19


Technical specifications20Dosing elementsAttachment of additional dosingelementsIntelligent Exchange Unit/DosingUnit with integral Data ChipDosing steps per cylinder volume(resolution)Operation, dialogStirrers, titration st<strong>and</strong>Attachment of Dosimats, Dosinos,stirrersSample Changer attachmentAttachment of balances, printer,PC, PC keyboard, barcode reader<strong>and</strong>/or Lab LinkAttachment of additional measuringmodules (867 pH Moduleor 856 Conductivity Module)PCMCIA memory-card portfor methods, results, Keycard(user identification), backupCompactFlash Card with a largenumber of user methodsTemperature sensorDifferential amplifierReal-time curve display onTouch Control (90 mm x 120 mmcolor graphics LCD) or PC screenDET Dynamic Equivalence-pointTitrationMET Monotonic EquivalencepointTitrationSET Titration to a preset endpointwith automaticconditioningKF Volumetric Karl Fischertitration with automaticconditioningSTAT Titration to a preset controlpoint <strong>and</strong> maintaining thecorresponding measuredvalueMEAS Measuring mode for pH,U/mV, T/°CMEAS CONC Direct measurementusing ISE <strong>and</strong> calculation ofconcentrationCAL Calibration with automaticbuffer recognition<strong>904</strong> Titr<strong>and</strong>o <strong>905</strong> Titr<strong>and</strong>o <strong>906</strong> Titr<strong>and</strong>o <strong>907</strong> Titr<strong>and</strong>o1 integrated Space for two 1 integrated Space for twoDosimat with 800 Dosinos with Dosimat with 800 Dosinos with806 Exchange Unit 807 Dosing Unit 806 Exchange Unit 807 Dosing UnitUp to 9 x 805 Dosimat with 806 Exchange UnitUp to 12 x 800 Dosino with 807 Dosing Unityes<strong>904</strong> Titr<strong>and</strong>o <strong>905</strong> Titr<strong>and</strong>o <strong>906</strong> Titr<strong>and</strong>o <strong>907</strong> Titr<strong>and</strong>owith 805 Dosimat: with 800 Dosino: with 805 Dosimat: with 800 Dosino:20‘000 10‘000 20‘000 10‘000Touch Control or PC Control / tiamo TM4 x 801 Magnetic Stirrer or 4 x 802 Rod Stirrer with 804 Titration St<strong>and</strong>or 803 KF Titration St<strong>and</strong>4 MSB connectors (Metrohm Serial Bus, Daisy Chain)1 sample changer via USBVia 2 USB Slave Ports, RS-232/USB Box (option)nonoyesyesyesPt 1000 or NTCOptionyesyesyesyesResolution: 0.001 pH, 0.1 mV, 0.1 °C;Measuring interval: 100 msyesyesyesyes


Second, galvanically separatedmeasuring interface for pH,U/mV, T/°CI pol & U pol – integratedprogrammable PolarizerAdditional possibilities oftitration-curve evaluation:fixed endpoints, pK values (HNP),minimum/maximum, break point(photometry or conductometry)Sequences can be freelyprogrammed by the userMethod <strong>and</strong> sample data memory,result memory, data baseDialog languages: English <strong>and</strong>German; additional languagescan easily be addedComprehensive GLP functions;meets requirements ofFDA 21 CFR Part 11Intelligent dosing devicesIntelligent electrodes «iTrodes»GLP-compliant electrode testCheck for result limitsAccess control by means of loginwith password protection;Electronic SignatureLiquid h<strong>and</strong>ling with exp<strong>and</strong>eddosing instructions for the800 Dosino<strong>904</strong> Titr<strong>and</strong>o <strong>905</strong> Titr<strong>and</strong>o <strong>906</strong> Titr<strong>and</strong>o <strong>907</strong> Titr<strong>and</strong>oOptionyesyesyesyesyesyesyesyesyesyesyesyes21


22Ordering information<strong>904</strong> Titr<strong>and</strong>o2.<strong>904</strong>.0010 <strong>904</strong> Titr<strong>and</strong>o with built-in buret drive <strong>and</strong> one combined analog/digital measuring input;delivery includes one 854 iConnect plus one «iEcotrode plus» combined pH electrode2.<strong>904</strong>.0020 <strong>904</strong> Titr<strong>and</strong>o with built-in buret drive <strong>and</strong> two combined analog/digital measuring inputs;delivery includes one 854 iConnect plus one «iEcotrode plus» combined pH electrode<strong>905</strong> Titr<strong>and</strong>o2.<strong>905</strong>.0010 <strong>905</strong> Titr<strong>and</strong>o with one combined analog/digital measuring input; delivery includesone 854 iConnect plus one «iEcotrode plus» combined pH electrode2.<strong>905</strong>.0020 <strong>905</strong> Titr<strong>and</strong>o with two combined analog/digital measuring inputs; delivery includesone 854 iConnect plus one «iEcotrode plus» combined pH electrode<strong>906</strong> Titr<strong>and</strong>o2.<strong>906</strong>.0010 <strong>906</strong> Titr<strong>and</strong>o with built-in buret drive <strong>and</strong> one combined analog/digital measuring input;delivery includes one 854 iConnect plus one «iEcotrode plus» combined pH electrode2.<strong>906</strong>.0020 <strong>906</strong> Titr<strong>and</strong>o with built-in buret drive <strong>and</strong> two combined analog/digital measuring inputs;delivery includes one 854 iConnect plus one «iEcotrode plus» combined pH electrode<strong>907</strong> Titr<strong>and</strong>o2.<strong>907</strong>.0010 <strong>907</strong> Titr<strong>and</strong>o with one combined analog/digital measuring input; delivery includesone 854 iConnect plus one «iEcotrode plus» combined pH electrode2.<strong>907</strong>.0020 <strong>907</strong> Titr<strong>and</strong>o with two combined analog/digital measuring inputs; delivery includesone 854 iConnect plus one «iEcotrode plus» combined pH electrode


Options2.840.0100 Touch Control Titr<strong>and</strong>o6.6050.100 PC Control software Titr<strong>and</strong>o, including Hardware Dongle2.800.0010 800 Dosino for <strong>905</strong> <strong>and</strong> <strong>907</strong> Titr<strong>and</strong>o <strong>and</strong> as additional dosing device for <strong>904</strong> <strong>and</strong> <strong>906</strong> Titr<strong>and</strong>o2.801.0040 801 Magnetic Stirrer2.802.0010 802 Rod Stirrer2.803.0010 803 KF Titration St<strong>and</strong>2.804.0040 804 Ti St<strong>and</strong>2.805.0010 805 Dosimat as additional dosing device for <strong>904</strong> <strong>and</strong> <strong>906</strong> Titr<strong>and</strong>o (<strong>and</strong> <strong>905</strong> <strong>and</strong> <strong>907</strong> Titr<strong>and</strong>o)2.847.0010 847 USB Lab Link2.854.0010 854 iConnect for connection of intelligent electrodes «iTrodes»236.2051.030 Holder for 840 Touch Control6.2834.030 Foils for 840 Touch Control, 3 pieces6.2133.010 Batteries 1.5 V LR6 for Touch Control, 2 pieces6.2247.000 Adapter CompactFlash Card – PCMCIA port (included in the st<strong>and</strong>ard accessories)6.2247.010 CompactFlash Card (empty; the st<strong>and</strong>ard acessories include a card with user methods)6.2148.010 Remote Box MSB6.2148.020 RS-232/USB Box6.2151.000 Cable USB A plug – Mini-DIN plug, 8 pins6.2151.010 Extension cable Mini-DIN socket – Mini-DIN plug, length 2 m6.2151.020 Cable USB A plug – USB B plug, length 1.8 m6.2151.030 Cable USB A plug – USB B plug, length 30 cm6.5104.030 Differential amplifier equipment with line adapter 230 V, EU plug6.5104.040 Differential amplifier equipment with line adapter 115 V, US plug6.2061.010 Reagent Organizer, holds two 1 L bottles; for dosing with Dosinos <strong>and</strong> Dosing UnitsIntelligent 807 Dosing Units equipped with Data Chip; with glass cylinder for 800 Dosino, including accessories <strong>and</strong>two buret tips, one of them with micro outlet valve6.3032.120 Buret volume 2 mL6.3032.150 Buret volume 5 mL6.3032.210 Buret volume 10 mL6.3032.220 Buret volume 20 mL6.3032.250 Buret volume 50 mLIntelligent 806 Exchange Units equipped with Data Chip; with glass cylinder <strong>and</strong> flat PCTFE/PTFE stopcock6.3026.110 1 mL Exchange Unit with one tip each for titration <strong>and</strong> dosing6.3026.150 5 mL Exchange Unit with one tip each for titration <strong>and</strong> dosing6.3026.210 10 mL Exchange Unit with one tip each for titration <strong>and</strong> dosing6.3026.220 20 mL Exchange Unit with one tip each for titration <strong>and</strong> dosing6.3026.250 50 mL Exchange Unit with one tip each for titration <strong>and</strong> dosing6.1542.010 Flat ceramic stopcock for 6.3026.XX0 Exchange Units6.1542.020 Replacement stopcock, PCTFE/PTFE, for 6.3026.XX0 Exchange Units


Subject to changeLayout by Ecknauer+Schoch ASW, printed in Switzerl<strong>and</strong> by Metrohm AG, CH-9101 Herisau8.<strong>904</strong>.5001EN – 2009-05www.metrohm.com