SYSTEMA S.p.A.10.2 MalfunctionsAIRTIGHT GAS-FIRED RADIANT TUBES INFRAFAULT CAUSE REMEDYThe burner lights and then becomesblocked after a few secondsa) phase and neutral are inverted in thea) invert the connections.electric power supply.b) poor earthing. b) check earthing.c) electrode position = 4 mm from thec) electrode or detection pin badly positionedplate (see diagram in this <strong>manual</strong>, page22).d) faulty control appliance.e) air in the gas pipes. e) bleed the aird) replace the appliance with an originalspare part.f) wrong gas pressure.f) check the pressure with the valuesgiven on the plate.IMPORTANT: please seal the adjustmentdevice of the gas valve after completingadjustmenta) no gas in the burner. a) check the supply line.b) the electrovalve coil is not activated b) check the connection of the siliconeby the interruption of the air pressure tube and operation of the air pressureThe fan motor starts, shortly afterwards switch.switch.the control unit attempts to light but thecombustion torch does not light.c) this may be checked with a screwdriver:the screwdriver is attracted byc) the electrovalve coil is fault.the coil during ignition.The fumes fan does not start.d) the methane gas pressure at thed) bring it to the plate value.nozzle is too high.a) no current.b) the motor is faulty.a) check the position of the switches onthe control panel and on the mainpanel.b) check the fan operation sepa-ratelyif it does not work, replace it with an originalspare part.c) replace it with a condenser that hasc) the condenser is faulty.the same characteristics.a) bleed any air from the plant, if it isa) check that gas is reaching the torch.new.The fan motor starts, the control unitb) the ignition electrode is badly positioned.diagram in this <strong>manual</strong>, page 19).b) position 4 mm from the plate (seeattempts to light, the electrovalveopens but the torch does not light.c) the gas pressure is too high. c) bring it to the plate value.a) during the initial check the appliance a) replace the pressure switch with anThe fan motor starts, but the control has found the pressure switch contacts original spare part with the same calibration.appliance does not give any signals to in a closed position (stuck).the torch and to the electrovalve.b) replace the appliance with an originalspareb) the control appliance is faulty.partRev. 18GB061054

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!