Download manual Download manual
SYSTEMA S.p.A.AIRTIGHT GAS-FIRED RADIANT TUBES INFRA8.3 Electrical diagram for control board fitted with FC M32C/FC E32C P.C.B.J1Power supplyL1= Phase line= Earthing lineN= Neutral lineT2= ResetS3= Working control lightB4= Failure control lightJ2Fan feeding suctionNM= Neutral suction= Earthing lineLM=Suction fan phase lineJ4Ignition electrode1= Yellow/green2= Brown3= Cyan4= Yellow/green5= --Fig. 48 Switch boardJ5Gas valve6= Yellow/green7= --8= Cyan9= BrownATTENTION!!IN CASE OF FC E32C DEVICE,THE RESET BUTTON DOES NOTOPERATE132Fig. 48b Reset switchFig. 48a Air pressure switchJ6Air pressure switch10= Blak (2)11= White (1)12= Pink (3)J7Reset switch13= Orange (2)14= Brown (1)15= Cyan (3)J716= Working control light17= Working control lightRev. 18GB061046
AIRTIGHT GAS-FIRED RADIANT TUBES INFRASYSTEMA S.p.A.8.4 Electrical cablingThe elctrical cabling for the burners BAF are lodged inside of an airtight box in PVC. They work with an electronic switchboard BRAHMA FC M32C/FC E32C/FC E32C and the electrical cabling are assembled on a special pre-pressed circuit.Fig. 49 Exploded drawing of the electrical cabling with electronic switch board BRAHMA FC M32C/FC E32C47Rev. 18GB0610
- Page 1 and 2: AIRTIGHT GAS-FIRED RADIANT TUBESINF
- Page 3 and 4: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 5 and 6: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 7 and 8: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 9 and 10: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 11 and 12: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 13 and 14: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 15 and 16: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 17 and 18: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 19 and 20: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 21 and 22: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 23 and 24: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 25 and 26: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 27 and 28: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 29 and 30: SYSTEMA S.p.A.AIRTIGHT GAS-FIRED RA
- Page 31 and 32: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 33 and 34: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 35 and 36: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 37 and 38: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 39 and 40: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 41 and 42: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 43 and 44: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 45: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 49 and 50: SYSTEMA S.p.A.AIRTIGHT GAS-FIRED RA
- Page 51 and 52: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 53 and 54: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 55 and 56: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 57 and 58: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 59: AIRTIGHT GAS-FIRED RADIANT TUBES IN
AIRTIGHT GAS-FIRED RADIANT TUBES INFRASYSTEMA S.p.A.8.4 Electrical cablingThe elctrical cabling for the burners BAF are lodged inside of an airtight box in PVC. They work with an electronic switchboard BRAHMA FC M32C/FC E32C/FC E32C and the electrical cabling are assembled on a special pre-pressed circuit.Fig. 49 Exploded drawing of the electrical cabling with electronic switch board BRAHMA FC M32C/FC E32C47Rev. 18GB0610