Download manual
Download manual Download manual
SYSTEMA S.p.A.6.4 Maximum lengthsAIRTIGHT GAS-FIRED RADIANT TUBES INFRA(1) Make sure that rooms are specifically ventilated fortype “B” applicationsType C32D= min.500 mmType C12D= min.500 mm(1)Type C32Type C12 Type B22 Type B22(1)Model and code Max. length Type ofModel Code Infra 6B Infra 9B Infra 12B dischargeDirectorycomponentCod. 00CNTE04429 7 715 13 13C32(fig. A)B22(fig. E)Fig. 36 atpage 35Fig. 40 atpage 39Cod. 00CNTE0444 9 7 7C12(fig.B)Fig. 37 atpage 36Cod. 00CNTE2598 15 13 13B22(fig. F)Fig. 41 atpage 40Cod. 00CNKI2515 5 3 3C32(fig. C)Fig. 38 atpage 37Cod. 00CNKI2514 6 4 4C12(fig. D)Fig. 39 apage 38Fig. 35 Table of maximum lengths of ducts and dimensionsRev. 18GB061034
AIRTIGHT GAS-FIRED RADIANT TUBES INFRA6.5 Components of disharge ad intake ducts6.5.1 Separate roof discharge (type C32)SYSTEMA S.p.A.Fig. 36 Separate roof discharge(type C32 fig.35 - A)Pos. Description Code Q.ty Pos. Description Code Q.ty1Aluminium connection tube Ø100 mmwith protection cap for air/fumes (ceiling)00CNTE0442 2 5Inox flexible/flexible joint forsingle layer rigid Ø 100 mm 00CNGI2542 32 Upper collarIncluded in00CNTE04422 6Single layerinox flexible tubeØ 100 mm for air only00CNTU0543Ml3 Plomb protection capIncluded in00CNTE04422 7Double layer inox flexible tubeØ 100 mm for fumes00CNTU0542Ml4 Flange hole coverIncluded in00CNTE04422 8Inox flexible/rigid joint for singlelayer rigid Ø 100 mm00CNGI2541 135Rev. 18GB0610
- Page 1 and 2: AIRTIGHT GAS-FIRED RADIANT TUBESINF
- Page 3 and 4: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 5 and 6: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 7 and 8: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 9 and 10: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 11 and 12: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 13 and 14: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 15 and 16: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 17 and 18: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 19 and 20: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 21 and 22: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 23 and 24: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 25 and 26: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 27 and 28: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 29 and 30: SYSTEMA S.p.A.AIRTIGHT GAS-FIRED RA
- Page 31 and 32: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 33: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 37 and 38: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 39 and 40: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 41 and 42: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 43 and 44: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 45 and 46: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 47 and 48: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 49 and 50: SYSTEMA S.p.A.AIRTIGHT GAS-FIRED RA
- Page 51 and 52: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 53 and 54: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 55 and 56: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 57 and 58: AIRTIGHT GAS-FIRED RADIANT TUBES IN
- Page 59: AIRTIGHT GAS-FIRED RADIANT TUBES IN
AIRTIGHT GAS-FIRED RADIANT TUBES INFRA6.5 Components of disharge ad intake ducts6.5.1 Separate roof discharge (type C32)SYSTEMA S.p.A.Fig. 36 Separate roof discharge(type C32 fig.35 - A)Pos. Description Code Q.ty Pos. Description Code Q.ty1Aluminium connection tube Ø100 mmwith protection cap for air/fumes (ceiling)00CNTE0442 2 5Inox flexible/flexible joint forsingle layer rigid Ø 100 mm 00CNGI2542 32 Upper collarIncluded in00CNTE04422 6Single layerinox flexible tubeØ 100 mm for air only00CNTU0543Ml3 Plomb protection capIncluded in00CNTE04422 7Double layer inox flexible tubeØ 100 mm for fumes00CNTU0542Ml4 Flange hole coverIncluded in00CNTE04422 8Inox flexible/rigid joint for singlelayer rigid Ø 100 mm00CNGI2541 135Rev. 18GB0610