EXTENDED REGISTER GROUPS<br />

RD2.ChkLowLim<br />

Low limit <strong>of</strong> resolver amplitude, when the amplitude falls below<br />

this value a resolver error interrupt is generated.<br />

RD2.ChkErr 12 0..4 RW<br />

i<br />

Reserved 13<br />

Reserved 14<br />

RD2.PosOffs 15 -2 31 ..2 31 -1 RW<br />

The position <strong>of</strong>fset that is used when RD2.RPos is read.<br />

RD2.FiltLen 16 0..3 RW<br />

RD2, Resolver/Digital converter #2<br />

⎛ sin max* 32768 ⎞<br />

RD 1. SinGain = 32768 − ⎜<br />

⎟<br />

⎝ cos max ⎠<br />

11 0..16384 RW<br />

The reason code for the last resolver error.<br />

0 = No error.<br />

1 = Exitation voltage has reached it’s highest output.<br />

2 = Exitation voltage has reached it’s lowest output.<br />

4 = Resolver amplitude has fallen below RD2.ChkLowLim.<br />

The error code will not be removed by the system. A user<br />

written PL code interrupt routine may clear this error after it<br />

has been read. The system will overwrite on next error.<br />

The length <strong>of</strong> the accumulating speed filter. The filter has<br />

variable length.<br />

Value Number <strong>of</strong> samples<br />

0 1<br />

1 2<br />

2 4<br />

3 8<br />

The RD2.Filtlen consists<br />

<strong>of</strong> the number <strong>of</strong> samples used in<br />

the mean value calculation. The resolver should not rotate when<br />

the length is changed.<br />

User's Manual 5.1 Inmotion Technologies AB<br />

Doc. No.9032 0027 01 (B), Rev. 11.07.2001<br />