28.11.2012 Views

Table of Contents - TG Drives

Table of Contents - TG Drives

Table of Contents - TG Drives

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

EXTENDED REGISTER GROUPS<br />

RD1, Resolver/Digital converter #1.<br />

RD1, RESOLVER/DIGITAL CONVERTER #1.<br />

Group Group<br />

No.<br />

Description<br />

RD1 2 Resolver/digtal converter #1 that is used for main<br />

motor communication and regulation.<br />

GENERAL<br />

The RD1 group contains registers for control and monitoring <strong>of</strong> the Resolver 1<br />

input, which is, used for primary feedback <strong>of</strong> motor position and speed.<br />

The resolver is supplied with a excitation frequency from the DMC 2 and outputs two<br />

amplitude modulated signals which represents the sine and cosine <strong>of</strong> the angular<br />

position at all times. These analog signals are sampled and converted at a<br />

constant rate (4 kHz). From the sine and cosine values, the angle can be<br />

calculated as arctan(sine/cosine).<br />

From this periodic angle measurement, the speed and position <strong>of</strong> the motor can be<br />

derived. The resolver gives an absolute position over one turn.<br />

The position unit is Increments (incs), where a two pole (single speed) resolver<br />

gives 8192 incs/turn, a four pole resolver gives 16384 incs/turn and so on.<br />

The speed unit then becomes Increments/second (incs/s) and the acceleration unit<br />

becomes: Increments/second 2 (incs/s 2 ) In high resolution mode these numbers are<br />

multiplied by 8.<br />

Resolver Resolver speed High resolution Mode Standard Mode<br />

PPR PPR<br />

2-Pole 1-Speed resolver 65536 8192<br />

4-Pole 2-Speed resolver 131072 16384<br />

6-Pole 3-Speed resolver 196608 24576<br />

8-Pole 4-Speed resolver 262144 32768<br />

FUNCTION<br />

Resolver 1 (RD1) must be set up properly in order to run the motor. The<br />

commutation <strong>of</strong> motor currents depends on proper operation <strong>of</strong> RD1.<br />

RD1.Mode Selects the mode <strong>of</strong> operation for the resolver interface.<br />

RD1.Mode = 0 turns <strong>of</strong>f the resolver and resets RD1.Pos.<br />

RD1. Mode = 1 Is the normal setting for standard resolvers. Other values<br />

enable special functions.<br />

RD1.SHAdj Compensates for phase shift in the resolver and cables. The<br />

synchronous demodulation principle <strong>of</strong> the resolver interface<br />

requires that this parameter is set to the proper value. A<br />

span <strong>of</strong> +/- 150 is sufficient for all types <strong>of</strong> resolvers. A<br />

measuring routine (PL2 coded) for this parameter is included<br />

in the SW package<br />

RD1.RPos Is used as the reference for all movements in the DMC 2 . This<br />

relative axis position can be set to any value by the<br />

statement Ref Pos .<br />

User's Manual 5.1 Inmotion Technologies AB<br />

Doc. No.9032 0027 01 (B), Rev. 11.07.2001<br />

57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!