EXTENDED REGISTER GROUPS<br />
LAN1, Local area network 1<br />
is approx. 50us when 1Mbit/sec CAN frequency is used.<br />
Conceptually, a particular node owns a message object. But<br />
any node can listen to this message object by defining a<br />
received message object with the same ID.<br />
If multiple messages are sent on a channel without any<br />
confirmation the some data will be overwritten in the receiving<br />
ends.<br />
There is no buffer for incoming messages so if a new<br />
message comes in (on the same channel) before the previous<br />
message was read, the old message is lost !!!!<br />
GROUP MEMBERS (GROUP 28)<br />
Group.Member Member<br />
No.<br />
Range Ability Default<br />
LAN1.Mode 0 0..255 R(W)<br />
Bit0 = 0<br />
Bit0 = 1<br />
Bit 0 is the only write able bit. All other bits are reserved and<br />
Read only.<br />
Normal operation.<br />
This bit should be low for normal operation. When this bit is<br />
high the CAN controller is disconnected from the net (bus <strong>of</strong>f).<br />
If this bit is set high then the CAN controller will be forced bus<br />
<strong>of</strong>f. It will reset the internal error handling and start a recovery<br />
sequence where the CAN low level protocol expects to see an<br />
idle bus.<br />
LAN1.Status 1 0..255 RW<br />
Bit 0-2 (0..7)<br />
Bit3(8)<br />
Bit4(16)<br />
Bit5(32)<br />
Bit6(64)<br />
Bit7(128)<br />
The LAN1.Status indicate the operation <strong>of</strong> the low protocol<br />
(CAN) chip.<br />
Last Error code, can also be read in member LAN1.LastErr.<br />
Transmit<br />
message successfully.<br />
Receive<br />
message successfully.<br />
Reserved.<br />
Warning. There is an abnormal rate <strong>of</strong> occurrences <strong>of</strong> errors<br />
on the CAN bus.<br />
Bus Off. There was an abnormal rate <strong>of</strong> occurrences <strong>of</strong> errors<br />
on the CAN bus.<br />
The unit is disconnected from the CAN bus.<br />
The only way to reset this situation is to force the LAN1.Mode<br />
bit0 high and<br />
then low (or cycle power).<br />
User's Manual 5.1 Inmotion Technologies AB<br />