28.11.2012 Views

Table of Contents - TG Drives

Table of Contents - TG Drives

Table of Contents - TG Drives

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

EXTENDED REGISTER GROUPS<br />

LAN1, Local area network 1<br />

is approx. 50us when 1Mbit/sec CAN frequency is used.<br />

Conceptually, a particular node owns a message object. But<br />

any node can listen to this message object by defining a<br />

received message object with the same ID.<br />

If multiple messages are sent on a channel without any<br />

confirmation the some data will be overwritten in the receiving<br />

ends.<br />

There is no buffer for incoming messages so if a new<br />

message comes in (on the same channel) before the previous<br />

message was read, the old message is lost !!!!<br />

GROUP MEMBERS (GROUP 28)<br />

Group.Member Member<br />

No.<br />

Range Ability Default<br />

LAN1.Mode 0 0..255 R(W)<br />

Bit0 = 0<br />

Bit0 = 1<br />

Bit 0 is the only write able bit. All other bits are reserved and<br />

Read only.<br />

Normal operation.<br />

This bit should be low for normal operation. When this bit is<br />

high the CAN controller is disconnected from the net (bus <strong>of</strong>f).<br />

If this bit is set high then the CAN controller will be forced bus<br />

<strong>of</strong>f. It will reset the internal error handling and start a recovery<br />

sequence where the CAN low level protocol expects to see an<br />

idle bus.<br />

LAN1.Status 1 0..255 RW<br />

Bit 0-2 (0..7)<br />

Bit3(8)<br />

Bit4(16)<br />

Bit5(32)<br />

Bit6(64)<br />

Bit7(128)<br />

The LAN1.Status indicate the operation <strong>of</strong> the low protocol<br />

(CAN) chip.<br />

Last Error code, can also be read in member LAN1.LastErr.<br />

Transmit<br />

message successfully.<br />

Receive<br />

message successfully.<br />

Reserved.<br />

Warning. There is an abnormal rate <strong>of</strong> occurrences <strong>of</strong> errors<br />

on the CAN bus.<br />

Bus Off. There was an abnormal rate <strong>of</strong> occurrences <strong>of</strong> errors<br />

on the CAN bus.<br />

The unit is disconnected from the CAN bus.<br />

The only way to reset this situation is to force the LAN1.Mode<br />

bit0 high and<br />

then low (or cycle power).<br />

User's Manual 5.1 Inmotion Technologies AB<br />

Doc. No.9032 0027 01 (B), Rev. 11.07.2001<br />