EXTENDED REGISTER GROUPS<br />

OptAD, analog to digital converter.<br />

OPTAD, ANALOG TO DIGITAL CONVERTER.<br />

Group Group<br />

No.<br />

Description<br />

OptAD 22 Optional analog to digital conversion.<br />

GENERAL<br />

The DMC equipped with this option has an analog input named M1. This channel<br />

has an individual gain setting. The gain setting is controlled with the<br />

OptAD.GainM1 member. The input is intended for a strain gauges transducer i.e. a<br />

load cell or a torque transducer. The connector also incorporates a balanced<br />

supply voltage <strong>of</strong> +/- 5 VDC.<br />

Channel Measuring range Purpose<br />

M1 ±50 mVDC Strain gauge<br />

transducer<br />

CONVERSION RESULOTION<br />

Extern measurement<br />

bridge is required.<br />

The AD resolution is 14 bit, and the result is sign extended to utilize the 32 bit PL<br />

register set.<br />

CALIBRATION<br />

The M1 channel has two resistances, 390 kΩ and 47kΩ, that can be used to<br />

calibrate an externally provided measurement bridge. When the value in the table<br />

is written to OptAD.Cal then the selected calibration resistance will be connected in<br />

parallel with one <strong>of</strong> the four legs in the Measurement Bridge.<br />

Value Channel Resulting calibration resistance.<br />

0 none Disconnect all calibration resistances.<br />

8 M1 390 kΩ<br />

9 M1 47 kΩ<br />

EXAMPLE USAGE<br />

; On startup.<br />

OptAD.Cal = 0 ; disconnect all calibration resistances.<br />

.. <br />

; Start calibration<br />

OptAD.Cal = 8 ; M1, calibration resistance = 390 kOhm<br />

R200 = OptAD.M2 ; Conversion is done within 200 us.<br />

.. <br />

OptAD.Cal = 0 ; disconnect all calibration resistances.<br />

<br />

; Start measuring<br />

R100 = OptAD.M1 ;and the result is stored in R100.<br />

; The calibration value in R200 is application dependent and<br />

; bridge dependent, and it can be used in several different<br />

ways.<br />

;<br />

; 1. Value may indicate what type <strong>of</strong> measurement<br />

User's Manual 5.1 Inmotion Technologies AB<br />

Doc. No.9032 0027 01 (B), Rev. 11.07.2001<br />

135