132<br />

Comm, Serial communication<br />

EXTENDED REGISTER GROUPS<br />

Comm.Node takes effect immediately. If an EEstore is done after,<br />

the new setting is valid after a power up; otherwise, the old value<br />

remains valid.<br />

To change the node number immediately to 3:<br />

>Comm.Node, 3<br />

To change the node number used when the DMC 2 is powered up<br />

to 3:<br />

>BCLR EEprom.6, 15<br />

>OR EEprom.6, 3<br />

>EEStore<br />

Comm.TLines 3 0..256 RW<br />

The number <strong>of</strong> lines displayed sequentially when many lines will<br />

follow. After Comm.TLines is displayed, the system prompts the<br />

user to continue. The user has the option <strong>of</strong> pressing the space<br />

bar for another screen page, or the ENTER key for one line at<br />

the time. Pressing Q terminates the listing.<br />

Comm.Rdy 4 0..1 R<br />

Indicates if the serial communication is busy handling a Csend<br />

instruction and if a computer mode session is active.<br />

Bit 0: 1: Csend is Idle<br />

0: Csend is Busy<br />

Bit 1: 1: Computer mode Idle<br />

Typical use:<br />

0: Computer mode Busy (start <strong>of</strong> record received)<br />

Wait Comm.Rdy and 2 ;wait for idle condition<br />

Csend R7 ;send the message<br />

Wait Comm.Rdy and 1 ;wait for message to be sent<br />

User's Manual 5.1 Inmotion Technologies AB<br />