EXTENDED REGISTER GROUPS<br />

X7A:6.<br />

In.PTC 11 0..1 R<br />

In.Fault 12 0..1 R<br />

In, Digital inputs<br />

The Out.Fault signal is<br />

binary AND’d with all internal fault<br />

signals and then brought to the Ready relay output.<br />

The result <strong>of</strong> the binary AND can be read in In.Fault<br />

(Reserved) 13 0..1 R<br />

NIU<br />

(Reserved) 14 0..1 R<br />

NIU<br />

(Reserved) 15 0..1 R<br />

NIU<br />

In.Level 16 0..65535 RW<br />

Bit0 (1) = 0<br />

Bit0 (1) = 1<br />

Sets the active level for each bit <strong>of</strong> the I/O ports. This variable<br />

can be used to adjust the input logic when an inverting input<br />

buffer board occurs, etc. Normally is not changed.<br />

Bit = 0: Active level is High. Do not invert data from input<br />

(default).<br />

Bit = 1: Active level is Low. Invert data from input.<br />

Active level is High for DI1. Do not invert data from input.<br />

Active level is Low for DI1. Invert data from input.<br />

Bit1 (2) = 0 Active level is High for DI2. Do not invert data from input.<br />

Bit2 (4) = 0 Active level is High for DI3. Do not invert data from input.<br />

Bit1 (8) = 0 Active level is High for DI4. Do not invert data from input.<br />

Bit1 (16) = 0 Active level is High for DI5. Do not invert data from input.<br />

Bit1 (32) = 0 Active level is High for DI6. Do not invert data from input.<br />

Bit1 (64) = 0 Active level is High for DI7. Do not invert data from input.<br />

Bit1 (128) = 0 Active level is High for DI8. Do not invert data from input.<br />

Bit1 (256) = 0 Active level is High for DI9. Do not invert data from input.<br />

Bit1 (512) = 0 Active level is High for DI10. Do not invert data from input.<br />

In.PDI 17 0..4095 R<br />

Parallel read <strong>of</strong> above I/O ports. Used to read more than one<br />

I/O at a time.<br />

Bit0 corresponds to Di1<br />

Bit1 corresponds to Di2 etc.<br />

b13 (8192) - User output short circuit indication. This bit<br />

indicates that one or several digital outputs are shorted to<br />

ground. (Outputs are short circuit protected).<br />

User's Manual 5.1 Inmotion Technologies AB<br />

Doc. No.9032 0027 01 (B), Rev. 11.07.2001<br />