102<br />

SysIo, System I/O<br />

EXTENDED REGISTER GROUPS<br />

For a master, when SysIo.Sync is 0, then this member is 0.<br />

SysIo.PowerStage 32 0..7 R<br />

Indicate the power stage type. Old power stages types will<br />

return 0.<br />

0 = No such information available.<br />

1 = DMC50412, 12Amp peak.<br />

2 = DMC30515, 15Amp peak.<br />

3 = DMC50720, 20Amp peak.<br />

4 = DMC31025, 25Amp peak. (NYI)<br />

5 = DMC51540, 40Amp peak. (NYI)<br />

6 = DMC32050, 50Amp peak. (NYI)<br />

7 = DMC53080 or DMC34080, 80Amp peak. (NYI)<br />

SysIo.DCBUS 33 0..1000 R<br />

Indicate the DC-bus voltage in Volts.<br />

Note. Only newer power parts support this, 4-10 A.<br />

SysIo.Compatible 34 0..1 RW 0<br />

Change the standard functionality <strong>of</strong> system functions.<br />

b0 (1) = Get and Set instruction, added functionality<br />

Sysio.SyncStat 35 0..31 R<br />

Status on external synch, only valid if Sysio.Sync = 1.<br />

Bit 2,bit 1 and bit0 holds a counter for incoming synch<br />

pulses. Normally these 3 bits shows the combined value <strong>of</strong> 6<br />

when synchronization is stable if the external signal<br />

disappears, the value becomes 0 after 6 mS. In this case <strong>of</strong><br />

missing synch signal the variable Sysio.SyncRate also<br />

becomes 0. Bit 3, (8), indicates if the incoming synch signal<br />

is higher than 1050 Hz (outside locking range). Bit4, (16),<br />

indicates if the incoming synch signal is lower than 950 Hz<br />

(outside locking range). Checking Sysio.SyncStat for these<br />

values may do a monitoring <strong>of</strong> the external synch.<br />

Ex: If Sysio.SyncStat = 6 then SyncOK<br />

Sysio.EditNo 36 0..99 R<br />

Edit level <strong>of</strong> the firmware. If EditNo is nonzero the firmware<br />

is a Beta release. Together with Sysio.RevNo the complete<br />

revision number can be formed.<br />

User's Manual 5.1 Inmotion Technologies AB<br />

Doc. No.9032 0027 01 (B), Rev. 11.07.2001