12.07.2015 Views

M011 RS232 – RS485 data converter

M011 RS232 – RS485 data converter

M011 RS232 – RS485 data converter

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>M011</strong><strong>RS232</strong> – <strong>RS485</strong><strong>data</strong> <strong>converter</strong>SummaryM010 is a <strong>RS232</strong> to <strong>RS485</strong> multi-speed half-duplex physical level <strong>converter</strong> withgalvanic separation at both ends. The device is equipped with a microcontrollerwhich controls the <strong>data</strong> flow switching.Applicationsdomat I/O modules link to PCany <strong>RS232</strong> to <strong>RS485</strong> conversion where galvanic separation is requiredFunctionsThe <strong>RS485</strong> bus supports half-duplex communication. For automatic flow control, amicrocontroller is used which is controlled by the CTS or DSR signals (DSR as default).The communication speed of both channels must be equal and is to be set by jumpersat the printed board. There are LEDs at the front panel to indicate power presence and<strong>RS485</strong> <strong>data</strong> flow.For the <strong>RS485</strong> connection, a RJ 45 connector is used. The line is protected againstovervoltage. In case the <strong>converter</strong> is used as the last in line, a terminating resistor maybe employed by connecting piano switch accessible behind the K1 connector.For the <strong>RS232</strong> connection, a CANON 9M (pins) connector is used. For PC connection,use nullmodem (cross) cable with CANON 9F (holes) at both ends. domat only usesRxD, TxD, and GND signals for PC communication.domat <strong>M011</strong> 1


Technical <strong>data</strong>Supply voltageConsumption10 V ÷ 35 V DC, 14 V ÷ 24 V AC, anypolarity1500 mWWorking temperature of the device 0 ÷ 70°CCommunicationBitsMax. bus lengthData flow controlDimensionsDefault settingsasynchronous <strong>RS485</strong>, 1200 ... 19200 bit/s8 or 9, 1 stopbit1200mautomatic, CTS or DSRsee belowBus End Off, <strong>RS485</strong>, SW, 8, 9600 (suitablefor domat I/O modules)Terminals andsettingsThe <strong>M011</strong> replaces the older type M010 (which was equipped by a RJ45 connector atthe <strong>RS485</strong> side) since June 2007.Bus End OffBus End On1 2 3 41,2,3: 4:000 1200 bps 0 8 bit100 2400 bps 1 9 bit010 4800 bps110 9600 bps001 19200 bps101 38400 bps011 57600 bps111 115200 bpsDimensions148,590458,5143621,553581006/2008 Subject to technical changes.2 domat <strong>M011</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!