2.2 Top and Bottom Side and End RailsNOT Acceptable Condition• Cuts, holes, gouges or splits.• Cracks in welds or parent metal.• Improper repairs.• Dents greater than 25 mm (1 inch).• Out of straight greater than 25 mm (1 inch) per 2 m (79 inch) length.• Distortion reducing clearance preventing operation of discharge valve.• Twisted or bent outwards beyond the limits of the ISO corner fittings.• Severe corrosion.• Loose or missing fasteners.________________________________________________________________________Acceptable Condition• Dents not exceeding 25 mm (1 inch).• Dents in bottom face of bottom rails which do not affect any formed edge.NOT Acceptable Condition2. 3 Ancillary Bracing• Cuts, holes, gouges or splits.• Cracks in welds or parent metal.• Improper repairs.• Dents and distortions greater than 25 mm (1 inch).• Distortion reducing clearance preventing operation of discharge valve• Twisted or bent outwards beyond the limits of the ISO corner dimensions.• Severe corrosion.NOT Acceptable Condition• Cuts, holes, gouges or splits.• Cracks in welds or parent metal.8WWW.itco.be
• Improper repairs.• Dents and distortions greater than 25 mm (1 inch).• Twisted or bent outwards beyond the limits of the ISO corner dimensions.• Severe corrosion._____________________________________________________________________________Acceptable Condition• Dents and distortions less than 25 mm (1 inch).2. 4 Tank Bearer Supports and Load Transfer AreasNOT Acceptable Condition• Cuts, holes, gouges or splits.• Cracks in welds or parent metal.• Improper repairs.• Dents or distortion of a formed edge greater than 13 mm (0.5 inch).• Dents and distortions of the face greater than 20 mm (0.75 inch).• Severe corrosion.• Twisted or bent outwards beyond the limits of the ISO corner fittings.NOTE:In all cases of damage to a tank bearer support the tank shell must also be inspectedfor damage. In all cases of corrosion to the tank bearer supports the section of thebearer attached to the shell below the insulation must be checked for structuralintegrity. This will require local removal of insulation2.5 Stacking Supports / Miss Stacking PlatesNOT Acceptable Condition• Cuts, holes, gouges or splits.• Cracks in welds or parent metal.• Improper repairs.• Dents and distortions greater than 25 mm (1 inch).• Twisted or bent outwards beyond the limits of the ISO corner dimensions.• Severe corrosion._____________________________________________________________________________Acceptable Condition• Dents and distortions less than 25 mm (1 inch).WWW.itco.be9
- Page 1 and 2: Acceptable Container ConditionITCO
- Page 3 and 4: IntroductionThis Tank Container Ins
- Page 5 and 6: Cleanliness1.1 InteriorNOT Acceptab
- Page 7: NOT Acceptable Condition___________
- Page 11 and 12: 5 Insulation and CladdingINSULATIO
- Page 14 and 15: 6. 3 Dipstick and Calibration Chart
- Page 16 and 17: Note :Flame arrestors are not neces
- Page 18 and 19: • Sharp indentations, creases or
- Page 20 and 21: • Customs sealing ring, missing
- Page 22 and 23: • Broken or missing retaining wir
- Page 24 and 25: NoteAll parts must be well-maintain
- Page 26 and 27: 13.3 Mandatory Tests 5 Year or 2 ½
- Page 28 and 29: TANK SERIAL NO.Location:Inspected B
• Improper repairs.• Dents and distortions greater than 25 mm (1 inch).• Twisted or <strong>be</strong>nt outwards <strong>be</strong>yond the limits of the ISO corner dimensions.• Severe corrosion._____________________________________________________________________________<strong>Acceptable</strong> <strong>Condition</strong>• Dents and distortions less than 25 mm (1 inch).2. 4 Tank Bearer Supports and Load Transfer AreasNOT <strong>Acceptable</strong> <strong>Condition</strong>• Cuts, holes, gouges or splits.• Cracks in welds or parent metal.• Improper repairs.• Dents or distortion of a formed edge greater than 13 mm (0.5 inch).• Dents and distortions of the face greater than 20 mm (0.75 inch).• Severe corrosion.• Twisted or <strong>be</strong>nt outwards <strong>be</strong>yond the limits of the ISO corner fittings.NOTE:In all cases of damage to a tank <strong>be</strong>arer support the tank shell must also <strong>be</strong> inspectedfor damage. In all cases of corrosion to the tank <strong>be</strong>arer supports the section of the<strong>be</strong>arer attached to the shell <strong>be</strong>low the insulation must <strong>be</strong> checked for structuralintegrity. This will require local removal of insulation2.5 Stacking Supports / Miss Stacking PlatesNOT <strong>Acceptable</strong> <strong>Condition</strong>• Cuts, holes, gouges or splits.• Cracks in welds or parent metal.• Improper repairs.• Dents and distortions greater than 25 mm (1 inch).• Twisted or <strong>be</strong>nt outwards <strong>be</strong>yond the limits of the ISO corner dimensions.• Severe corrosion._____________________________________________________________________________<strong>Acceptable</strong> <strong>Condition</strong>• Dents and distortions less than 25 mm (1 inch).WWW.itco.<strong>be</strong>9