Step 5: <strong>Combustion</strong> <strong>Air</strong>System: Blower and airpressure switch (continued)Note:The use of an inlet air filter is strongly recommended. Thesystem will per<strong>for</strong>m longer and the settings will be morestable.Note:When selecting a 60 Hz Blower <strong>for</strong> use on 50 Hz, a pressureand capacity calculation is required. See <strong>Eclipse</strong> <strong>Combustion</strong>Engineering Guide (EFE 825).Inlet filter withreplaceable filterelementThe total selection in<strong>for</strong>mation you should now have:• Blower model number• Motor hp• Motor enclosure (TEFC)• Voltage, number of phases, frequency• Rotation direction (CW or CCW).<strong>Air</strong> pressure switchThe air pressure switch gives a signal to the monitoring systemwhen there is not enough air pressure from the blower.You can find more in<strong>for</strong>mation on pressure switches in BlowerBulletin 610Step 6: Main gas shut-offvalve trainMain gasshut-offvalve train<strong>Air</strong> pressure switchWarning:<strong>Eclipse</strong> supports NFPA regulations, which requirethe use of an air pressure switch in conjunctionwith other safety components, as a minimumstandard <strong>for</strong> main gas safety shut-off systems.Consult <strong>Eclipse</strong><strong>Eclipse</strong> can help you design and obtain a main gas shut-off valvetrain that complies with the current safety standards.The shut-off valve train must comply with all the local safetystandards set by the authorities that have jurisdiction.For details, please contact your local <strong>Eclipse</strong> representative orthe <strong>Eclipse</strong> factory.Note<strong>Eclipse</strong> supports NFPA regulations (two shut-off valves) as aminimum standard <strong>for</strong> main gas safety shut-off systems.Step 7: Process TemperatureControl SystemConsult <strong>Eclipse</strong>The process temperature control system is used to control andmonitor the temperature of the system. There is a wide varietyof control and measuring equipment available.For details, please contact your local <strong>Eclipse</strong> representative orthe <strong>Eclipse</strong> factory.18 <strong>Eclipse</strong> <strong>ThermJet</strong> PCA Design Guide No. 206, 3/5/07

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!