Step 5: <strong>Combustion</strong><strong>Air</strong> System: Blower andair pressure switchEffects of atmospheric conditionsThe blower data is based on the International Standard Atmosphere(ISA) at Mean Sea Level (MSL), which means that it isvalid <strong>for</strong>:•••Sea level29.92” Hg (1,013 mbar)70ºF (21ºC)The make-up of the air is different. above sea level or in a hotarea. The density of the air decreases, and as a result, the outletpressure and the flow of the blower decrease. An accurate descriptionof these effects is in the <strong>Eclipse</strong> <strong>Combustion</strong> EngineeringGuide (EFE 825). The Guide contains tables to calculate theeffect of pressure, altitude and temperature on air.BlowerThe rating of the blower must match the system requirements.You can find all the blower data in Bulletin/Info Guide 610Follow these steps:1. Calculate the outlet pressure.<strong>Preheated</strong> <strong>Air</strong> Pressure DropCorrection FactorsIf combustion airtemperature is:400º F600º F800º F1000º FSeries SMJ turbo blowerMultiply60º F drop by:1.652.042.422.81Note:For a given combustion air flow, system pressure dropsincrease with air temperature. Multiply calculated cold airpressure drops by the appropriate factor in the chart at leftto arrive at the preheated air drop.When calculating the outlet pressure of the blower, the total ofthese pressures must be calculated.• The static air pressure required at the burner found in theburner Data Sheet, 206-1 to 206-13• The total pressure drop in the piping• The total of the pressure drops across the valves• The pressure in the chamber (suction or pressurized)<strong>Eclipse</strong> recommends a minimum safety margin of 10%2. Calculate the required flowThe blower output is the air flow delivered under standard atmosphericconditions. It must be enough to feed all the burnersin the system at high fire and provide the eductor flow.<strong>Combustion</strong> air blowers are normally rated in terms of standardcubic feet per hour (scfh) of air.An example calculation follows the in<strong>for</strong>mation tables.<strong>Eclipse</strong> <strong>ThermJet</strong> PCA Design Guide No. 206, 3/5/0715

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!