G. Setpoints MenuDisplayOperationalSPFactorySettingRange/Choices180°F 60°F to 230°FOn Point -5°F 0°F to -99°FOff Point 15°F 0°F to 99°FHighTempStopDHWPSetpointWWSDSetpointMax SPWaterheaters230°FWaterHeaters200°F60°F to 230°F180°F 140°F to 230°F70°F 40°F to 90°FWaterheaters230°FWaterHeaters200°F140°F to 230°FMin SP 140°F 60°F to 230°FMin InH 2OTempMax H 2ODelta TMaxDelta THold130°F 110°F to 180°F50°F 20°F to 50°F50°F 20°F to 50°FDescriptionOperational SPSetpoint used in Local Setpoint Mode when not servicing a Domestic Hot Water Priority (DHWP)request.On PointThe water heater starts when the water temperature drops “On Point” degrees below the setpoint.Off PointThe water heater stops when the water temperature rises “Off Point” degrees above the setpoint.High Temp StopThe water heater stops when water temperature is above the High Temperature Stop setpoint. Thissetpoint is active in every control mode.DHWP SetpointThe Domestic How Water Priority (DHWP) Setpoint is active when DHW Input (DP) closes and“DHWP” parameter is set to “yes” and Local SP Mode is selected. When the contact is closed, thewater heater outlet is maintained at, or above, the DHW Setpoint.WWSD SetpointThe Warm Weather Shutdown (WWSD) Setpoint used to disable water heater and/or system pumpoperation when enabled by setting the “WWSD” parameter to “WWSD of Water heater”, “WWSD ofSys Pump” or “Both”Max SPThe Maximum Operational Setpoint for all possible Local and Remote Modes.Min SPThe Minimum Operational Setpoint is the lower limit for all Local and Remote modes.Min In H 2O Temp.Minimum Inlet Water Temperature Setpoint used as the Mixing Valve inlet temperature setpoint.Only visible when Mixing Valve equals Yes.Max H 2O Delta TMaximum Water Differential (Water heater Outlet minus Water heater Inlet) temperature setpoint usedas the Mixing Valve differential temperature setpoint.Only visible when Mixing Valve equals yes.Max Delta T HoldMaximum Water differential (Water heater Outlet minus Water heater Inlet) Temperature used to holdmodulation rate at low fire.56

H. Communication MenuDisplayProtocolModbusAddressBaudRateParityFactorySettingPeer-To-PeerRange/ChoicesPeer-To-PeerModbus1 1 - 24719.2Odd9.619.238.4OddEvenNoneTimeout 30 1 - 120MessagesRcvdMessagesSentWaterheaterAddressOnlineStatus1 1 to 8XXXXXXXXDescriptionProtocolSelects between Peer-To-Peer (Multiple water heater lead/lag control network) and a Modbus slavecommunication.Modbus AddressEach water heater must be given a unique address.Only visible when Protocol equals Modbus.Baud RateUnits are 1000 Bits Per Second (KBPS).Only visible when Protocol Equals Modbus.ParityOnly visible when Protocol equals Modbus.TimeoutOnly visible when Protocol equals Modbus.Messages RcvdDiagnostic tool used to confirm wiring and Modbus master configuration.Only visible when Protocol equals Modbus.Messages SentDiagnostic tool used to confirm wiring and Modbus master configuration.Only visible when Protocol equals Modbus.Water heater AddressEach Water heater must be given a unique address. The water heater address assignment determinesthe water heater sequencing order. A value of 0 disables the network communications.Only visible when Protocol equals Peer-To-Peer.Online StatusEach space can be either the water heater address or a “-” depending on whether there is a waterheater of that address online.Example: _ _ 6 _ _ 321 indicates that water heaters 6, 3,2, and 1 are online.Only visible when Protocol equals Peer-To-PeerI. Manual Mode MenuDisplayFactorySetting101 AutoRange/ChoicesManAuto102 Varies 0 to 100103 Varies104 AutoOnOffManAuto105 Varies 0 to 100DescriptionWater heater Man/AutoMan: Remain in Manual ModeAuto: Return to Water heater Mode specified by parameter/water heater conditions.Activated only when in Supervisor Mode.Modulation RateSets the modulation rate to be sued for water heater when in Manual Mode.Activated only when in Supervisor Mode and Water heater Man/Auto = Man.Water heater On/OffSets the water heater start/stop status when in Manual Mode.No: Turn of water heater if running, otherwise remain off.Yes: Turn on water heater if off, otherwise remain on.Activated only when in Supervisor Mode and Water heater Man/Auto = Man.Mixing Valve M/AMan: Remain in Manual ModeAuto: Return to Control Mode specified by parameter/water heater conditionsActivated only when in Supervisor Mode.Mixing ValveSets the Mixing Valve % Open to be used for valve when in Manual Mode.Activated only when in Supervisor Mode and Mixing Valve M/A equals Man.57

H. Communication MenuDisplayProtocolModbusAddressBaudRateParityFactorySettingPeer-To-PeerRange/ChoicesPeer-To-PeerModbus1 1 - 24719.2Odd9.619.238.4OddEvenNoneTimeout 30 1 - 120MessagesRcvdMessagesSent<strong>Water</strong>heaterAddress<strong>On</strong>lineStatus1 1 to 8XXXXXXXXDescriptionProtocolSelects between Peer-To-Peer (Multiple water heater lead/lag control network) and a Modbus slavecommunication.Modbus AddressEach water heater must be given a unique address.<strong>On</strong>ly visible when Protocol equals Modbus.Baud RateUnits are 1000 Bits Per Second (KBPS).<strong>On</strong>ly visible when Protocol Equals Modbus.Parity<strong>On</strong>ly visible when Protocol equals Modbus.Timeout<strong>On</strong>ly visible when Protocol equals Modbus.Messages RcvdDiagnostic tool used to confirm wiring and Modbus master configuration.<strong>On</strong>ly visible when Protocol equals Modbus.Messages SentDiagnostic tool used to confirm wiring and Modbus master configuration.<strong>On</strong>ly visible when Protocol equals Modbus.<strong>Water</strong> heater AddressEach <strong>Water</strong> heater must be given a unique address. The water heater address assignment determinesthe water heater sequencing order. A value of 0 disables the network communications.<strong>On</strong>ly visible when Protocol equals Peer-To-Peer.<strong>On</strong>line StatusEach space can be either the water heater address or a “-” depending on whether there is a waterheater of that address online.Example: _ _ 6 _ _ 321 indicates that water heaters 6, 3,2, and 1 are online.<strong>On</strong>ly visible when Protocol equals Peer-To-PeerI. <strong>Manual</strong> Mode MenuDisplayFactorySetting101 AutoRange/ChoicesManAuto102 Varies 0 to 100103 Varies104 Auto<strong>On</strong>OffManAuto105 Varies 0 to 100Description<strong>Water</strong> heater Man/AutoMan: Remain in <strong>Manual</strong> ModeAuto: Return to <strong>Water</strong> heater Mode specified by parameter/water heater conditions.Activated only when in Supervisor Mode.Modulation RateSets the modulation rate to be sued for water heater when in <strong>Manual</strong> Mode.Activated only when in Supervisor Mode and <strong>Water</strong> heater Man/Auto = Man.<strong>Water</strong> heater <strong>On</strong>/OffSets the water heater start/stop status when in <strong>Manual</strong> Mode.No: Turn of water heater if running, otherwise remain off.Yes: Turn on water heater if off, otherwise remain on.Activated only when in Supervisor Mode and <strong>Water</strong> heater Man/Auto = Man.Mixing Valve M/AMan: Remain in <strong>Manual</strong> ModeAuto: Return to Control Mode specified by parameter/water heater conditionsActivated only when in Supervisor Mode.Mixing ValveSets the Mixing Valve % Open to be used for valve when in <strong>Manual</strong> Mode.Activated only when in Supervisor Mode and Mixing Valve M/A equals Man.57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!