F. System Configuration MenuDisplayDHWPRemoteControlRemote1.0 volt =Remote9.0 volt =RemoteSensorSystemPumpLWC orCADAlarmMessageFactorySettingOffNoRange/ChoicesOffIsolatedDemandShared DemandNo140°F 60°F to 170°F220°F 150°F to 220°FNoNoNo16 TextCharactersNoDisplay <strong>On</strong>lyControlNoYesNoYes“Low <strong>Water</strong>Level”DescriptionDHWPEnables Domestic Hot <strong>Water</strong> Priority (DHWP) control feature. When input (DP) is energized DHWPbecomes active as selected:No DHWP.<strong>Water</strong> heater that received the input (DP) drops off the Peer-To-Peer network and its temperaturesetpoint is adjusted above the DHWP setpoint. The PID output is based on water heater outlet temperatureand setpoint. If Remote SP or Remote System temperature sensor were selected, control isswitched to the <strong>Water</strong> heater Outlet Sensor.If the lead water heater receives the input (DP) the temperature setpoint for all water heaters on thepeer-to-peer network is adjusted above the DHWP setpoint.Remote ControlSets the remote (Energy Management System) control mode as follows:Local setpoint and modulation rate is used. Modbus and remote input (C+,C-) are ignored.Remote 1.0 Volt =Sets the temperature corresponding to the input (C+,C-) 1 Volt. Voltage below 1V is consideredinvalid, (failed or miswired sensor.)Remote 9.0 Volt =Sets the temperature corresponding to the input (C+,C-) 9 volts. Voltage above 9V is consideredinvalid (failed or miswired sensor.)Remote SensorEnables the Remote System Temperature sensor display and control logic:Remote Sensor Input (R+,R-) is ignored.Remote Sensor Input (R+,R-) is used for display only.Control Remote Sensor Input (R+,R-) is compared with the temperature setpoint to establish a modulationrate.System PumpEnables the System Pump Output (SO)LWC or CADSpecifies a Low <strong>Water</strong> Cut-off Switch or Combustion Air Damper (Fresh Air Damper). Open switch isconnected to input (LC). Enables Limit Hold and alarm messages.Alarm MessageLimit Hold and alarm message displayed corresponding to sensor connected to input (LC).The “ENTER” key and “up” and “Down” arrow keys are used to change the text message.55

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!