12.07.2015 Views

I&O Manual - Solaris Water Heaters - Categories On Thermal ...

I&O Manual - Solaris Water Heaters - Categories On Thermal ...

I&O Manual - Solaris Water Heaters - Categories On Thermal ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

E. Boiler Configuration MenuDisplayDisplayUnits<strong>Water</strong>heaterPumpPumpPrepurgePostpurgeΔTInlet SensorMixingValveSet Time/DateSpareInputFuel limitSpareOutputFactorySetting°FNoneRange/Choices°F°CNoneAlways <strong>On</strong>PurgeLead <strong>On</strong>15 0 to 6005 0 to 20YesNo____OffYes(if applicable)OffNoYesNoYeshour : minuteMonth / day /yearOffSys Pump FBLow FireNoYesOffCADSystem PumpBUSoft AlarmDescriptionDisplay UnitsSelects how temperature parameter values are displayed.<strong>Water</strong> heater PumpNo <strong>Water</strong> heater Pump.Pump Runs Continuously.Pump Runs during pump pre/post purge operations and during call for heat and then turns off.Lead water heater’s pump runs continuously when the water heater is the lead water heater andrevers to “Purge” operation when it is a lag water heater.Pump PrepurgeSets length of time the water heater pump will be run prior to closing the “Call for Heat” relay (CH).<strong>On</strong>ly visible when <strong>Water</strong> heater Pump does not equal None.Postpurge ΔTDefines the temperature above BIT that BOT must be at or below before turning off the water heaterpump during pump post purge (Pump Cooldown State).<strong>On</strong>ly visible when <strong>Water</strong> heater Pump does not equal None.Inlet SensorEnables the inlet temperature display and control logic.Mixing ValveEnables the mixing valve control output and user display.Set Time/DateSets the time and date of the water heater’s real time clock. This item also displays the time and date.Spare InputSet the function of the Spare Input Terminal (SL):IgnoreInput (SI) should be wired to a flow switch inserted in the flow of the of the primary system pump. Input(SI) indicates the primary system pump is operating. If output (SO) is set to System Backup Pump,system pump output (SO) is energized and System Pump Feedback is de-energized the SystemBackup Pump output (SO) is energized.When the Fuel Valve Energized input (SC) is not energized and input (SI) is energized the modulationrate is set to the “Low Fire Spd” setpoint. When input (SI) is not energized the modulation rate is set to“Fan Purge Spd” setpoint. When the fuel valve energized input (CS) is energized input (SI) is ignored.Specifies whether high and low cas pressure switches are connected to input (GP).Enables Fuel Limit Hold and alarm messages. (No)Spare OutputSets the function of the Spare Output Terminal (SO):Never close output (SO).Closes SO relay with a call for heat, Opens SO relay 2 minutes after call for heat has been deactivated.Closes when System Pump output is activated but the System Pump Feedback indicates the PrimarySystem Pump is not operating.Close when any alarm is active.54

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!