12.07.2015 Views

I&O Manual - Solaris Water Heaters - Categories On Thermal ...

I&O Manual - Solaris Water Heaters - Categories On Thermal ...

I&O Manual - Solaris Water Heaters - Categories On Thermal ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

C. Trouble Shooting GuideAlarm Messages are shown one at a time in priority order. The message closest to the top of this list is displayed first. Followingmessages are not show until the higher priority message has cleared. All alarm messages are also stored in the fault history.LCD DisplayAlarm MessageLow <strong>Water</strong> LevelOff SwitchLow <strong>Water</strong> FlowFuel LimitHigh Temp LimitLow Air FlowFSG FaultOutlet Temp FailInlet Temp FailOA Temp FailRecommendedAction<strong>Manual</strong>ly Reset the Low<strong>Water</strong> CutoffTurn Burner Switch <strong>On</strong>Ensure <strong>Water</strong> heaterPump is Running and<strong>Water</strong> heater<strong>Water</strong> Flow isUnobstructed<strong>Manual</strong>ly Reset the FuelPressure Switch<strong>Manual</strong>ly Reset theHigh TemperatureAquastatCheck Combustion AirBlower and AirPressure SwitchSettings and Wiring<strong>Manual</strong>ly ResetRequired, Refer toFlame Safeguard<strong>Manual</strong>Corrective ActionsCheck Wiring andSensorCheck Wiring andSensorCheck Wiring andSensorExplanationLow <strong>Water</strong> Cutoff SwitchWhen this option is configured and an instrument is installed, the manual resetlow water safety relay is preventing the water heater from starting. If terminal(LC) does not receive power and the Call For Heat output (CH) is powered the“Low <strong>Water</strong> Level” Message is displayed.Burner Switch is OffControl switch is in the OFF position and is preventing the water heater fromstarting. If terminal (OO) does not receive power and the Call For Heat output(CH) is powered the “OFF Switch” Message is displayed.Low <strong>Water</strong> Flow SwitchLow water flow is preventing the water heater from starting. If terminal (WF) doesnotreceive power and the Call For Heat output (CH) is powered the “Low <strong>Water</strong>Flow” Message is displayed.Low or High Gas Pressure SwitchThe low or high gas pressure switch is preventing the water heater from starting.Ifterminal (GP) does not receive power and the Call For Heat output (CH) ispowered the “Fuel Limit” Message is displayed.High Limit TemperatureThe high temperature limit (HL) (and operational temperature limit whenprovided) aquastat is preventing a water heater start. If terminal (HL) does notreceive power and the Call For Heat output (CH) is powered the “High TempLimit”Message is displayed.Low Air Flow or Blocked Vent Switch Not MadeThe air flow (and blocked vent switch when provided) is preventing a water heaterstart. If terminal (CA) does not receive power and the Call For Heat output (CH)ispowered the “Low Air Flow” Message is displayed.Flame Safeguard FaultThe Flame Safeguard is preventing a water heater start. If terminal (AL) receivespower at any time, the “Flame Failure” Message is displayed.<strong>Water</strong> heater Outlet Temperature Sensor FailThe water heater outlet temperature sensor is not connected or is reading aboveor below a valid range. When the water heater outlet sensor fails and the OutletSensor mode was selected the control will transfer to Lost Sensor Blind Mode.<strong>Water</strong> heater Inlet Temperature Sensor FailThe water heater inlet temperature sensor is not connected or is reading aboveor below a valid range. When the water heater inlet sensor fails the mixing valveoutput will drive to 0% and low temperature alarm and maximum water differential(water heater outlet minus water heater inlet) temperature hold are disabled.Outside Air Temperature Sensor FailThe outside air sensor is configured and is not connected or is reading above orbelow a valid range. When the outside air sensor fails the warm weather shutdown(WWSD) and outside air reset control logics are disabled.46

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!