5.Repair of faultsRepair of faults43DeutschFault Possible cause RemedyExtraction performancetoo weak(Fumes are notor only hardlyextracted).The device doesnot start.Filter elements are saturated.The throttle valve of the suctionhood is closed.The suction hose or suction arm isnot or not correctly closed.The clean air outlet is narrowed orcovered.The suction duct is narrowed.The suction element is damaged.The mains plug is not or notcorrectly plugged into the socket.The socket is not supplied withvoltage.Replace the filter elements, dispose of theused filters appropriately!Open the throttle valve.Check the position of the suction hose orthe suction arm and connect it if necessary.Check the clean air outlet, repair the fault ifnecessary.Check the suction duct, repair the fault ifnecessary.Replace the extraction element.Check/correct the mains connection.Check the electric circuit.If necessary, consult an electrician.EnglishPolski EspañolFrançais