12.07.2015 Views

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

None of <strong>the</strong> data read is transferred to <strong>the</strong> processor module; <strong>the</strong> data field is merelyread and <strong>the</strong> generated check character is compared against <strong>the</strong> check character read from<strong>the</strong> disk for that sector. If <strong>the</strong> check characters are identical, a normal device-end interruptionrequest is presented to <strong>the</strong> processor module with <strong>the</strong> end-of-sector ISW bit (bit 7)also set. If <strong>the</strong> check characters are not identical, <strong>the</strong> file-data-check bit (bit 4) is set in<strong>the</strong> interrupt status word and an interruption request is presented.Write Diagnostic Control0 5 8 11 16 20 26 31Op code R Fun Zeros Mod DA MA00001 XXX 001 00000 1011 ** * ***XXXXXX1111 II II 1111 III 11111 111110 8-F 2 0 B 0 0-3 XThis command disconnects <strong>the</strong> disk file from its controlling circuitry in <strong>the</strong> disk storagemodule so that certain signals and timing pulses can be simulated for testing by <strong>the</strong> customerengineer.The control information word used by this command is contained in <strong>the</strong> index register(R), or <strong>the</strong> accumulator if R=000, and has <strong>the</strong> following format:0 4 5 6 1011 13 15X 000 XXXO 00 XX 0 X 0 X1111111111111BitWrite oscillator 0Address mark indicate 4Separated clock 5Separated data 6Index 10Track crossing 11Set file ready 13Reset diagnostic mode 15The write diagnostic control command is used in conjunction with <strong>the</strong> read ISWEX command,described later.Before signals and timing pulses can be simulated with this command, <strong>the</strong> disk file mustbe placed in diagnostic mode by executing a write-diagnostic-control command with a controlinformation word containing 0. A bit in <strong>the</strong> ISWEX turns on and remains on to indicatethat <strong>the</strong> disk storage module is in diagnostic mode. The file can enter diagnosticmode only if it is not in any o<strong>the</strong>r mode at that time. While <strong>the</strong> file is in diagnostic mode,all o<strong>the</strong>r read and write commands can be issued to <strong>the</strong> disk storage module just as if <strong>the</strong>module were not in diagnostic mode.15-18 GA34-0003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!