12.07.2015 Views

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Set Diagnostic Mode0 5 8 11 16 20 26 31Op code R Fun Zeros Mod DA MA0 0 0 0 1 XXXO 0 1 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 XXXXXXI I I I ii 1 1 1 1 i 1 III I 1 1 1 1 1 1 1 1 1S■111.,../.11•••■ ••••••■••,•■•■• ••■■••••,■■••■••■••••■„,....■•••■•,■•••■••••■•■••■•,....../.....11..,■■••0 8-F 2 0 2 8 0-3 XThis command places <strong>the</strong> 2790 Control function in one of four states, depending upon <strong>the</strong>value of bits 14 and 15 in <strong>the</strong> index register (R), or <strong>the</strong> accumulator if R=000.The four possible states set by this command are:Bits State14 150 1 Diagnostic mode. The 2790 Control is set in diagnosticmode of operation for use with <strong>the</strong> set-input-buffercommand described later. ISW bit 5 is also set on toindicate that <strong>the</strong> diagnostic mode is effective. While in<strong>the</strong> diagnostic mode, <strong>the</strong> 2790 Control constantly checksfor <strong>the</strong> presence of sync characters in bytes 5 to 29 of aframe cycle. Any missing sync bytes are indicated by settingon bit 6 in <strong>the</strong> ISW.1 01 10 0Set Input Buffer ControlLoop bypass. The 2790 loop is bypassed. Output from <strong>the</strong>output buffer register is connected directly to <strong>the</strong> input of<strong>the</strong> input buffer register.Diagnostic and loop bypass. Output frames from <strong>the</strong> 2790Control enter directly into <strong>the</strong> input buffer register and arechecked for sync characters in bytes 5 to 29.Normal operation. This code resets <strong>the</strong> above three states andremoves <strong>the</strong> 2790 Control from <strong>the</strong> diagnostic and/or bypassmodes of operation.0 5 8 11 16 20 26 31Op code R Fun Zeros Mod DA MA0 0 0 0 1 XXX 0 0 1 0 0 0 0 0 0 0 1 1 1 0 0 0 0 0 XXXXXX!ill i i I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 10 8-F 2 0 3 8 0-3 XThis command loads a sync character (hexadecimal 47) or a character containing all l'sinto <strong>the</strong> input buffer register, depending on <strong>the</strong> setting of bit 15 in <strong>the</strong> index register (R),or <strong>the</strong> accumulator if R=000. A set-diagnostic-mode command must set <strong>the</strong> 2790 Controlfunction in diagnostic mode before executing a set-input-buffer-control command.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!