12.07.2015 Views

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

The range bits (RRR) in <strong>the</strong> control word specify <strong>the</strong> input voltage range and <strong>the</strong> amplifiergain desired, as shown in <strong>the</strong> following table.RRR Bits Input Voltage Range Amplifier Gain000 Automatic gain001 +10 mV 512010 +20 mV 256011 +40 mV 128100 +80 mV 64101 +160 mV 32110 +640 mV 8111 +5.12V 1When automatic gain is specified (RRR bits=000), <strong>the</strong> optimum gain (one of <strong>the</strong> sevenamplifier gains) is selected automatically, based upon <strong>the</strong> input signal voltage. The selectedgain can be returned to <strong>the</strong> program, along with <strong>the</strong> converted signal data, by issuing aread-ADC command. Since <strong>the</strong> indication of gain requires three bits, <strong>the</strong> input data itselfis reduced to 12 bits plus sign.The range bits (RRR) have no significance if <strong>the</strong> high-level amplifier is installed.This convert-analog-input command starts an analog-to-digital conversion cycle of <strong>the</strong>analog input point specified by <strong>the</strong> multiplexer address field in <strong>the</strong> control word. Aninterruption request occurs at <strong>the</strong> end of <strong>the</strong> conversion cycle. The results of <strong>the</strong> conversionare <strong>the</strong>n obtained by issuing a read-ADC or read-ADC-extended-precision command.With <strong>the</strong> read-ADC command, <strong>the</strong> data format is in short form (12 bits plus sign) ifautomatic gain was specified, or in standard form (14 bits plus sign) if a programmedrange was specified. The read-ADC-extended-precision command always returns <strong>the</strong> data instandard form.Convert Analog Input with External Synchronization0 5 8 11 16 20 26 31Op code R Fun Zeros Mod DA MA00001 XX OO10000000 011 001 00XXXXXX1111 It tt lilt III t Illi 111110 8-F 2 0 1 9 0-3 XThis command functions in <strong>the</strong> same manner as <strong>the</strong> convert-analog-input command exceptthat <strong>the</strong> start of conversion depends upon <strong>the</strong> receipt of an external synchronization inputpulse.The user provides <strong>the</strong> external synchronization input pulse to start <strong>the</strong> analog-to-digitaldata conversion. (Refer to <strong>the</strong> <strong>System</strong>17 Installation Manual—Physical Planning, OrderNo. GA34-0004, for more detailed data on <strong>the</strong> external synchronization input pulse.)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!