12.07.2015 Views

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Read /SW0 5 8 11 16 20 26 31Op code R Fun Zeros Mod. DA MA00001 X X X 010000000011100100 XXXXXX1111 II 11 Ili! III 11111 11111•••■••■,,,•••••••■■■••■.,•■•.,■61.,,••■I••■■••,,.■••.,0 8-F 4 0 3 9 0-3 XThis command stores <strong>the</strong> 16-bit interrupt status word (ISW) associated with <strong>the</strong> analoginput module into <strong>the</strong> index register (R), or <strong>the</strong> accumulator if R=000.Interrupt Status Word (ISW) • The 16 bits in <strong>the</strong> interrupt status word are set by conditionsoccurring after a convert-analog-input, convert-analog-input-with-external-synchronization,or read-and-convert-analog-input command is completed, but while <strong>the</strong> device is still busy.Since <strong>the</strong>se errors cannot be indicated to <strong>the</strong> program by <strong>the</strong> condition code, interruptionsresult from setting on any ISW bit except <strong>the</strong> busy bit. Setting on any one of bits 3through 7 also sets on <strong>the</strong> summary status indicator when <strong>the</strong> resulting interruption requestoccurs. After <strong>the</strong> interruption is accepted, executing any command o<strong>the</strong>r than read DSWresets <strong>the</strong> ISW.The significant bits in <strong>the</strong> ISW and <strong>the</strong>ir meanings are:Significant Bits Meaning3 Analog-to-digital converter inoperative.5 Invalid analog data. The polarity of <strong>the</strong> input voltage changed during<strong>the</strong> conversion cycle.7 Overload. The voltage read by <strong>the</strong> ADC was greater than <strong>the</strong> inputvoltage range selected by <strong>the</strong> amplifier.12 Device busy. The analog input module is converting an input voltage.13 Device end. The conversion operation requested is complete. If errorconditions occur during <strong>the</strong> execution of I/O commands, this bit isset on along with o<strong>the</strong>r error identifying bits.15 Invalid multiplexer address. An input point was addressed that is notinstalled.Read DSW0 5 8 11 16 20 26 31Op code000011111RXXXIIFunZeros010000000111111111Mod111DA11111MAX XXXXX11111•••■•••,....../ ....ww.„,.■■••••■■•••,,,■•••0 8-F 4 0 7 0 0-3 XThis command stores <strong>the</strong> 16-bit device status word (DSW) associated with <strong>the</strong> analog inputmodule into <strong>the</strong> index register (R), or <strong>the</strong> accumulator if R=000. Execution of thiscommand resets <strong>the</strong> bits in <strong>the</strong> DSW.<strong>IBM</strong> 5014 Analog Input Module Model CI 11-7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!