12.07.2015 Views

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Read ISW0 5 8 11 16 20 26 31Op code R Fun Zeros Mod DA MA00001 XXX 010000000011100100 XXXXXXMI 11 II [Ill III 1 1111 11111••••■•••,,e•■••••••••••••,■‘ ,.........„,....,■..011.,..11•••• •■•••■,,,■•••.••■■■••■,./.1•••,■■•••■,,••••■•• •••••••••,...11w,0 8-F 4 0 3 9 0-3 XThis command stores <strong>the</strong> 16-bit interrupt status word (ISW) associated with <strong>the</strong> analoginput module into <strong>the</strong> index register (R), or <strong>the</strong> accumulator if R=000.Interrupt Status Word (ISW): The 16 bits in <strong>the</strong> interrupt status word are set by conditionsoccurring after a convert-analog-input or a convert-analog-input-with-external-synchronizationcommand is completed but while <strong>the</strong> device is still busy. Since <strong>the</strong>se errors cannot beindicated to <strong>the</strong> program by <strong>the</strong> condition code, interruptions result from setting on anyISW bit except <strong>the</strong> busy bit. Setting on any one of bits 3 through 7 also sets on <strong>the</strong>summary status indicator when <strong>the</strong> resulting interruption request occurs. After <strong>the</strong> interruptionis accepted, executing any command o<strong>the</strong>r than read DSW resets <strong>the</strong> ISW.The significant bits in <strong>the</strong> ISW and <strong>the</strong>ir meanings are:Significant Bits Meaning3 Analog-to-digital converter inoperative.5 Multiple relays selected. This multiplexer failure is caused by morethan one input being selected during <strong>the</strong> conversion cycle.6 No relays selected. This multiplexer failure results from no inputbeing selected during <strong>the</strong> conversion cycle.7 Overload. The voltage read by <strong>the</strong> ADC was greater than <strong>the</strong> inputvoltage range selected by <strong>the</strong> amplifier.12 Device busy. The analog input module is converting an input voltage.13 Device end. The conversion operation requested is complete. If errorconditions occur during <strong>the</strong> execution of I/O commands, this bit isset on along with o<strong>the</strong>r error identifying bits.15 Invalid multiplexer address. An input point was addressed that wasnot installed.Read DSW0 5 8 11 16 20 26 31Op code R Fun Zeros Mod DA MA00001 XXX 010 000000111 ******XXXXXXI t II i i II II i I Ill 11 III 111110 8-F 4 0 7 0 0-3 XThis command stores <strong>the</strong> 16-bit device status word (DSW) associated with <strong>the</strong> analog inputmodule into <strong>the</strong> index register (R), or <strong>the</strong> accumulator if R=000. Execution of thiscommand resets <strong>the</strong> bits in <strong>the</strong> DSW.10-6 GA34-00037,7 • 1 III I ■ I 1p

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!