12.07.2015 Views

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

The four functions of keyboard entry, print, tape read, and tape punch are controlledby separate I/O commands.Since <strong>the</strong> operator station is used for only relatively short periods of time, <strong>the</strong> motorin <strong>the</strong> operator station can be turned off and on by program control. The operator stationcommand descriptions below specify if <strong>the</strong> motor must be started before issuing <strong>the</strong>secommands. It is advisable to turn off <strong>the</strong> motor when <strong>the</strong> station will not be in use.Turn On Motor0 5 8 11 16 20 26 31Op code Fun Zeros Mod DA MA0 0 0 0 1 X X X 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 01111 I 1 1 1111 I I I 11111 111110 8-F 2 0 8 2 0 0This command starts <strong>the</strong> operator station motor. An interruption request is presented to<strong>the</strong> system but <strong>the</strong> response time is <strong>the</strong> result of a complex relationship involving systemprogramming, system hardware, and system operation. This interrelationship results inan interruption request that may occur from several microseconds to more than fourseconds after <strong>the</strong> command has been issued. Therefore, <strong>the</strong> programmer is cautionedagainst using time-dependent code.Note: This interruption request will occur even if <strong>the</strong> operator station motor is turnedoff at <strong>the</strong> operator station, or if <strong>the</strong> operator station power is turned off by <strong>the</strong> powerswitch.Condition code 2 is returned if <strong>the</strong> operator station adapter is busy or has an interruptionpending. The contents of <strong>the</strong> R field are ignored.Turn Off Motor and Lock Keyboard0 5 8 11 16 20 26 31Op code R Fun Zeros Mod DA MA00001 XXX 00100000000000100000 0 0 0 01111 II 11 1111 III 11111 111110 8-F 2 0 0 2 0 0This command stops <strong>the</strong> operator station motor and locks <strong>the</strong> keyboard. No interruptionsoccur as a result of this command. The contents of <strong>the</strong> R field are ignored.Print Only0 5 8 11 16 20 26 31Op code Fun Zeros Mod DA MA0 0 0 0 1 X X X 0 0 1 0 0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 0 0 0 0 01111 1 1 1111 I I I 11111 11111s••■■••,,,•■■•■■■•.,,••••■■■■••••,,■••■•••■••••■,,■,••■■■■••••••■•••'•■••••.„,■.••••••■.,,•■••/.........~0 8-F 2 0 2 2 0 0This command sends one character to <strong>the</strong> operator station for printing. The single characteris obtained from bits 8 to 15 of <strong>the</strong> index register specified by <strong>the</strong> R field, or from <strong>the</strong>accumulator if R=000. After <strong>the</strong> character is printed, <strong>the</strong> operator station adapter presentsan interruption request.<strong>IBM</strong> 5028 Operator Station 9-7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!