12.07.2015 Views

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RequestThis switch serves a dual function in <strong>the</strong> operator station. When momentarily pressed once,<strong>the</strong> request switch generates an interruption request to <strong>the</strong> processor and sets indicatorbit 0 in <strong>the</strong> operator station interrupt status word. A light inside <strong>the</strong> request switchturns on under program control when <strong>the</strong> operator station is in remote mode to indicatethat <strong>the</strong> program requires information from <strong>the</strong> keyboard.EOM (End of Message)This switch, when momentarily pressed once, generates an interruption request to <strong>the</strong>processor and sets indicator bit 3 in <strong>the</strong> operator station interrupt status word. The keyboardmust be enabled; that is, <strong>the</strong> request switch light is on.LocalThis switch places <strong>the</strong> operator station in <strong>the</strong> local mode of operation. When in localmode, <strong>the</strong> operator station is disconnected from <strong>the</strong> system and can be tested by <strong>the</strong> CE orused as a tape punch to prepare tapes for subsequent use.The local switch also turns on <strong>the</strong> motor if it has been turned off by <strong>the</strong> motor-offswitch.PunchThis switch turns on or off <strong>the</strong> paper tape punch when <strong>the</strong> operator station is in local modeof operation. The switch is pressed once to turn on <strong>the</strong> punch, and once to turn off <strong>the</strong>punch. When <strong>the</strong> tape punch is turned on and <strong>the</strong> operator station is in local mode, anycharacter read from <strong>the</strong> tape reader or entered from <strong>the</strong> keyboard is punched into papertape.INITIAL PROGRAM LOAD (IPL)The two right-hand storage data/address switches must be set to a load unit address ofhexadecimal 00 prior to performing an initial program load operation from <strong>the</strong> tape readerin <strong>the</strong> operator station.When <strong>the</strong> program load key on <strong>the</strong> <strong>System</strong>/7 operator console is pressed, a system resetoccurs and <strong>the</strong> operator station adapter turns on <strong>the</strong> motor, locks <strong>the</strong> keyboard, disables<strong>the</strong> printer, and feeds tape until a hole is detected (that is, a nonzero character is read).The adapter <strong>the</strong>n starts to transfer characters, two characters (bytes) at a time, inorder to fill each 16-bit storage location word. Storing begins with location 0 and continuesconsecutively until location 127 is filled. (See Figure 9-3.)The <strong>System</strong>/7 cannot be interrupted during this data transfer. Any error detected duringthis portion of <strong>the</strong> IPL procedure requires operator intervention. If an error occurs, <strong>the</strong>tape stops moving, but <strong>the</strong> load light on <strong>the</strong> system operator console remains on until resetby <strong>the</strong> reset key.Following <strong>the</strong> transfer of 128 words of data, a branch is made automatically to location 0and <strong>the</strong> system begins executing instructions on priority level 3. At this time, <strong>the</strong> tapestops moving, but <strong>the</strong> operator station motor remains on.The IPL operation just described can also be started by <strong>the</strong> auto restart function. When<strong>the</strong> IPL operation is complete and program execution begins, bit 0 of <strong>the</strong> level 3accumulator will be set off if <strong>the</strong> IPL was a result of <strong>the</strong> program load key. Bit 0 will beset on if <strong>the</strong> IPL was <strong>the</strong> result of an auto restart operation. (See "Auto Rstrt Switch"and "Program Load Key" in Chapter 5.)<strong>IBM</strong> 5028 Operator Station 9-5...r.m.•••••9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!