12.07.2015 Views

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

IBM System/7 Functional Characteristics - All about the IBM 1130 ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

I■ 0=11 1111111 MEM11 1111111111 1111111 1111InnINITIAL PROGRAM LOAD (IPL)The host processor determines when to initiate an IPL to <strong>the</strong> <strong>System</strong>/7 through <strong>the</strong> ACCA.The IPL is <strong>the</strong>n initiated by means of a special IPL sequence of characters (see Figure 7-6).This IPL is allowed only when <strong>the</strong> host attach switch on <strong>the</strong> <strong>System</strong>/7 console is in <strong>the</strong>enable and IPL position, and <strong>the</strong> ACCA is in standby mode of operation. The <strong>System</strong>/7program can, however, reject <strong>the</strong> IPL when <strong>the</strong> same special character sequence is receivedby <strong>the</strong> ACCA, as described later in this discussion.An IPL is initiated by a host processor that sends <strong>the</strong> unique sequence of characters EOA,US, DEL, DS at <strong>the</strong> beginning of a message. The EOA character places <strong>the</strong> ACCA in receivemode and <strong>the</strong> US character is a control character to <strong>the</strong> ACCA. The DEL characteris decoded as <strong>the</strong> first data character. If interruption requests have been enabled by a prepareI/O command, this decoded character presents an interruption request to <strong>the</strong> processor(a character-received request). At this time <strong>the</strong> controlling program can interpret<strong>the</strong> circumstances leading up to <strong>the</strong> request and, if desired, issue a reset ACCA commandto reject <strong>the</strong> IPL. If <strong>the</strong> ACCA is not reset at this time, and <strong>the</strong> ACCA receives <strong>the</strong> DScharacter, a system reset occurs in <strong>the</strong> <strong>System</strong>/7, <strong>the</strong> processor is put into <strong>the</strong> load state,and <strong>the</strong> ACCA enters IPL mode. IPL data that is received by <strong>the</strong> ACCA is translated <strong>the</strong>same as if <strong>the</strong> ACCA were operating in binary data mode, described previously.Loading into <strong>System</strong>/7 storage begins at location 0000 and continues sequentially untilterminated by <strong>the</strong> host. The <strong>System</strong>/7 load light is turned on during this time. If no errorsare detected by <strong>the</strong> host, it terminates <strong>the</strong> IPL operation with <strong>the</strong> characters EOB andLRC to indicate a normal ending. If no errors are detected by <strong>the</strong> ACCA during <strong>the</strong> message,<strong>the</strong> ACCA transmits a positive response to <strong>the</strong> host and exits from IPL mode. Atthis time, <strong>the</strong> <strong>System</strong>/7 processor branches to location 0000 to begin program executionon priority level 3, and <strong>the</strong> ACCA remains in receive mode. If interruption requests areenabled by a prepare I/O command, receipt of an EOT character from <strong>the</strong> host presentsan interruption request to <strong>the</strong> processor (ISW bit 13 and <strong>the</strong> summary status indicatorare set). When <strong>the</strong> EOT character is decoded, <strong>the</strong> ACCA enters standby mode of operation.Sequence usedwith station controloption onlyEOT SOAHost ®CD SP<strong>System</strong>/7Notes:0VW60 1 1YAKCan be ON if an error occursIPL sequenceEOA DELUS DSIPL text EOB EOT(binary data)CILRC 0First wordin 00002 3 4 0 5VAYAK,ACCA must be in standby mode'Interruption if prepared3 <strong>System</strong> reset if host attach switch is in enable and IPL position (ACCA in IPL mode)4 <strong>System</strong> reset and start program5 ACCA in standby mode6 AddressFigure 7-6. Initial program load operationAV V7-14 GA34-0003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!